Non-Invasive Methods of Delamination Monitoring in Multi-Layer Structures

2012 ◽  
Vol 518 ◽  
pp. 238-245 ◽  
Author(s):  
Joanna Iwaniec ◽  
Marek Iwaniec

In the paper there are discussed the most interesting methods dedicated to frescos structural health monitoring. In the further part two methods and devices for fresco delamination detection developed by authors are presented. In order to enable future automation of developed measurement techniques and autonomic detection of fresco structural defects, the novel measures quantifying the probability of critical condition appearance (the lack of adhesive force) were introduced. Finally, the results of measurements of dynamic characteristics of healthy and delaminated structures are presented.

2021 ◽  
Vol 11 (3) ◽  
pp. 1235
Author(s):  
Su Min Yun ◽  
Moohyun Kim ◽  
Yong Won Kwon ◽  
Hyobeom Kim ◽  
Mi Jung Kim ◽  
...  

The development of wearable sensors is aimed at enabling continuous real-time health monitoring, which leads to timely and precise diagnosis anytime and anywhere. Unlike conventional wearable sensors that are somewhat bulky, rigid, and planar, research for next-generation wearable sensors has been focused on establishing fully-wearable systems. To attain such excellent wearability while providing accurate and reliable measurements, fabrication strategies should include (1) proper choices of materials and structural designs, (2) constructing efficient wireless power and data transmission systems, and (3) developing highly-integrated sensing systems. Herein, we discuss recent advances in wearable devices for non-invasive sensing, with focuses on materials design, nano/microfabrication, sensors, wireless technologies, and the integration of those.


Author(s):  
Patrick Magee ◽  
Mark Tooley

Blood pressure measurement occurs either non-invasively or invasively, and usually refers to systemic arterial pressure measurement, but can also refer to systemic venous or pulmonary arterial pressure measurement. In 1733 the Reverend Stephen Hales was the first person to measure the blood pressure in vivo in unanaesthetised horses by direct cannulation of the carotid and femoral arteries. In doing so he observed the pulsatile nature of flow in the circulation. In 1828 Poiseuille developed the mercury manometer, and used it to measure blood pressure in a dog. The mercury manometer has, of course, become the standard technique against which other techniques are compared. The earliest numerical information on blood pressure measurement came from direct rather than indirect measurement in 1856 by Faivre, using Poiseuille’s device. However, in the last part of the nineteenth century, non-invasive measurement techniques were developed. In 1903, Codman and Cushing introduced the concept of routine intraoperative blood pressure measurement, which at the time was a revolutionary concept. Nowadays it is a fundamental part of minimal monitoring criteria. There are several techniques of non-invasive BP (NIBP) measurement, all of which function by occluding the pulse in a limb with a proximal cuff, then detecting its onset again distally, on lowering the cuff pressure. Detection methods include palpation, auscultation, plethysmography, oscillotonometry and oscillometry. Accuracy of all non-invasive techniques depends on cuff size in relation to the limb concerned, and over which artery the cuff is placed. Such techniques of NIBP measurement are necessarily intermittent. Much discussion has taken place on the accuracy of these devices, and the accuracy of diastolic pressure measurements needs improving, and there are ideas proposed for new non-invasive devices [Tooley and Magee 2009]. In the absence of a stethoscope, this technique is simple and reliable. After inflating the cuff on the upper arm to a pressure of above that of systolic, the cuff is then deflated while palpating the brachial artery and the systolic pressure is measured with a mercury column at first detection of the pulse. A study by van Bergen [1954] showed that BP can be underestimated by this method by up to 25% at 120 mmHg.


Author(s):  
Nabraj Bhattarai ◽  
Subarna Khanal ◽  
Pushpa Raj Pudasaini ◽  
Shanna Pahl ◽  
Dulce Romero-Urbina

Citrate stabilized silver (Ag) colloidal solution were synthesized and characterized for crystallographic and surface properties by using transmission electron microscopy (TEM) and zeta potential measurement techniques. TEM investigation depicted the size of Ago ranges from 5 to 50 nm with smaller particles having single crystal structure while larger particles with structural defects (such as multiply twinned, high coalescence and Moire patterns). ?-potential measurement confirms the presence of Ag+ in nAg stock solution. The shift in ?-potential measurement by +25.1 mV in the filtered solution suggests the presence of Ag+ in Ago nanoparticles.


Sign in / Sign up

Export Citation Format

Share Document