Determination of Migration of 11 Organotin Compounds in Food Contact Materials by GCMS

2020 ◽  
Vol 984 ◽  
pp. 58-63
Author(s):  
Guang Bao Ye

The determination of the migration of 11 organotin compounds in food contact materials by GC-MS was established. The gastric acid was simulated with 0.07 mol/L hydrochloric acid solution, and the sample was soaked and extracted, and then derivatized with sodium tetraethylborate, extracted with n-hexane liquid solution, detected by GC-MS, and quantified by internal standard method. The linear range of the method is 5~600 μg/L, the correlation coefficient is greater than 0.997, and the method detection limit is 0.014 mg/kg. The recoveries of the three concentration levels ranged from 83.6% to 105.6% with a relative standard deviation of less than 11.4%. The method is simple and sensitive, and can be used for detecting the migration of organotin compounds in food contact materials.

1968 ◽  
Vol 22 (5) ◽  
pp. 434-437 ◽  
Author(s):  
E. A. Hakkila ◽  
R. G. Hurley ◽  
G. R. Waterbury

Two methods were evaluated for determining rare earths in plutonium: (1) For the lighter rare earths ( Z≦66), or low concentrations of the heavier rare earths, an adjacent rare earth was added as a carrier and also as an internal standard, the rare earths were separated from plutonium by fluoride precipitation, and the measured intensity ratios for the sample and for solutions having known concentrations were compared. The Lβ1 x-rays were measured for the lighter rare earths and the Lα1 x rays for the remaining lanthanides. (2) For the heavier rare earths ( Z>66), the Lα1 x-ray intensities were measured from a nitric acid solution of the sample and compared to intensities obtained for solutions having known concentrations. The minimum concentrations that could be measured with a relative standard deviation no greater than 4% by the separation internal standard method varied from approximately 0.5% for lanthanum to 0.01% for lutetium. The direct measurement of x-ray intensity was much less sensitive. Applicability of the methods was shown by successful analyses of plutonium alloys containing dysprosium, thulium, or lutetium.


The Analyst ◽  
2020 ◽  
Vol 145 (8) ◽  
pp. 2892-2896
Author(s):  
Xianshuang Meng ◽  
Yueguang Lv ◽  
Qing Lv ◽  
Yulin Deng ◽  
Hua Bai ◽  
...  

A methodology is presented for the determination of pyrethroid preservatives in wooden food contact materials using DART coupled with quadrupole-Orbitrap HRMS.


2016 ◽  
Vol 64 (46) ◽  
pp. 8866-8875 ◽  
Author(s):  
Marjeta Česen ◽  
Dimitra Lambropoulou ◽  
Maria Laimou-Geraniou ◽  
Tina Kosjek ◽  
Urška Blaznik ◽  
...  

2011 ◽  
Vol 29 (5) ◽  
pp. 417-421 ◽  
Author(s):  
Wei HAN ◽  
Yanjun YU ◽  
Ningtao LI ◽  
Libing WANG

Sign in / Sign up

Export Citation Format

Share Document