scholarly journals The detection of lumpy skin disease virus in samples of experimentally infected cattle using different diagnostic techniques

Author(s):  
E.S.M. Tuppurainen ◽  
E.H. Venter ◽  
J.A.W. Coetzer

Lumpy skin disease (LSD) is a disease of cattle, primarily in Africa and Madagascar and rarely in the Middle East. It is caused by a capripoxvirus that belongs to the family Poxviridae. The disease is of economic importance in endemic areas. Effective control of LSD requires accurate and rapid laboratory techniques to confirm a tentative clinical diagnosis. Comparative studies on different diagnostic tests used at different stages of the disease have not been done. The aim of this study was to compare several of these tests. Six seronegative bulls, between 11 and 20 months of age, were infected intravenously and kept in an insect-free facility. The course of the infection was monitored. During a 3-month period blood samples and skin biopsies were collected for virus isolation and polymerase chain reaction (PCR). Skin biopsies were also examined using transmission electron microscopy (TEM). The incubation period in infected animals varied from 4-5 days. The length of the viraemic period did not correlate with the severity of clinical disease. Viraemia was detected from 1-12 days using virus isolation and from 4-11 days using the PCR, which is longer than has previously been reported. Virus was isolated from skin biopsies until Day 39 post infection (p.i.) and PCR could demonstrate viral DNA until Day 92 p.i. Transmission electron microscopy of negatively stained skin biopsies detected LSD virus only in one of the four bulls that developed skin lesions until Day 33 p.i. The PCR was a fast and sensitive method to demonstrate viral DNA in blood and skin samples. It could detect viral nucleic acid in skin lesions 53 days longer than virus isolation. Virus isolation from blood and skin samples was sensitive and reliable, but as a single test it may be too time-consuming to use although this depends on how rapidly the diagnosis must be confirmed. In conclusion, this study showed the PCR to be superior in detecting LSD virus from blood and skin samples. However, virus isolation is still required when the infectivity of the LSD virus is to be determined. Indexed by Sabinet Online

2021 ◽  
Vol 9 (10) ◽  
pp. 2171
Author(s):  
Laetitia Aerts ◽  
Andy Haegeman ◽  
Ilse De Leeuw ◽  
Wannes Philips ◽  
Willem Van Campe ◽  
...  

Lumpy skin disease (LSD) diagnosis is primarily based on clinical surveillance complemented by PCR of lesion crusts or nodule biopsies. Since LSD can be subclinical, the sensitivity of clinical surveillance could be lower than expected. Furthermore, real-time PCR for the detection of LSD viral DNA in blood samples from subclinical animals is only intermittently positive. Therefore, this study aimed to investigate an acceptable, easily applicable and more sensitive testing method for the detection of clinical and subclinical LSD. An animal experiment was conducted to investigate ear notches and biopsies from unaffected skin taken from the neck and dorsal back as alternatives to blood samples. It was concluded that for early LSD confirmation, normal skin biopsies and ear notches are less fit for purpose, as LSDV DNA is only detectable in these samples several days after it is detectable in blood samples. On the other hand, blood samples are less advisable for the detection of subclinical animals, while ear notches and biopsies were positive for LSD viral DNA in all subclinically infected animals by 16 days post infection. In conclusion, ear notches could be used for surveillance to detect subclinical animals after removing the clinical animals from a herd, to regain trade by substantiating the freedom of disease or to support research on LSDV transmission from subclinical animals.


Author(s):  
G. G. Shaw

The morphology and composition of the fiber-matrix interface can best be studied by transmission electron microscopy and electron diffraction. For some composites satisfactory samples can be prepared by electropolishing. For others such as aluminum alloy-boron composites ion erosion is necessary.When one wishes to examine a specimen with the electron beam perpendicular to the fiber, preparation is as follows: A 1/8 in. disk is cut from the sample with a cylindrical tool by spark machining. Thin slices, 5 mils thick, containing one row of fibers, are then, spark-machined from the disk. After spark machining, the slice is carefully polished with diamond paste until the row of fibers is exposed on each side, as shown in Figure 1.In the case where examination is desired with the electron beam parallel to the fiber, preparation is as follows: Experimental composites are usually 50 mils or less in thickness so an auxiliary holder is necessary during ion milling and for easy transfer to the electron microscope. This holder is pure aluminum sheet, 3 mils thick.


Author(s):  
R. W. Anderson ◽  
D. L. Senecal

A problem was presented to observe the packing densities of deposits of sub-micron corrosion product particles. The deposits were 5-100 mils thick and had formed on the inside surfaces of 3/8 inch diameter Zircaloy-2 heat exchanger tubes. The particles were iron oxides deposited from flowing water and consequently were only weakly bonded. Particular care was required during handling to preserve the original formations of the deposits. The specimen preparation method described below allowed direct observation of cross sections of the deposit layers by transmission electron microscopy.The specimens were short sections of the tubes (about 3 inches long) that were carefully cut from the systems. The insides of the tube sections were first coated with a thin layer of a fluid epoxy resin by dipping. This coating served to impregnate the deposit layer as well as to protect the layer if subsequent handling were required.


Author(s):  
S. Fujishiro

The mechanical properties of three titanium alloys (Ti-7Mo-3Al, Ti-7Mo- 3Cu and Ti-7Mo-3Ta) were evaluated as function of: 1) Solutionizing in the beta field and aging, 2) Thermal Mechanical Processing in the beta field and aging, 3) Solutionizing in the alpha + beta field and aging. The samples were isothermally aged in the temperature range 300° to 700*C for 4 to 24 hours, followed by a water quench. Transmission electron microscopy and X-ray method were used to identify the phase formed. All three alloys solutionized at 1050°C (beta field) transformed to martensitic alpha (alpha prime) upon being water quenched. Despite this heavily strained alpha prime, which is characterized by microtwins the tensile strength of the as-quenched alloys is relatively low and the elongation is as high as 30%.


Author(s):  
Nakazo Watari ◽  
Yasuaki Hotta ◽  
Yoshio Mabuchi

It is very useful if we can observe the identical cell elements within the same sections by light microscopy (LM), transmission electron microscopy (TEM) and/or scanning electron microscopy (SEM) sequentially, because, the cell fine structure can not be indicated by LM, while the color is; on the other hand, the cell fine structure can be very easily observed by EM, although its color properties may not. However, there is one problem in that LM requires thick sections of over 1 μm, while EM needs very thin sections of under 100 nm. Recently, we have developed a new method to observe the same cell elements within the same plastic sections using both light and transmission (conventional or high-voltage) electron microscopes.In this paper, we have developed two new observation methods for the identical cell elements within the same sections, both plastic-embedded and paraffin-embedded, using light microscopy, transmission electron microscopy and/or scanning electron microscopy (Fig. 1).


Author(s):  
R.R. Russell

Transmission electron microscopy of metallic/intermetallic composite materials is most challenging since the microscopist typically has great difficulty preparing specimens with uniform electron thin areas in adjacent phases. The application of ion milling for thinning foils from such materials has been quite effective. Although composite specimens prepared by ion milling have yielded much microstructural information, this technique has some inherent drawbacks such as the possible generation of ion damage near sample surfaces.


Sign in / Sign up

Export Citation Format

Share Document