Cryptosporidium Contamination in Harvesting Areas of Bivalve Molluscs

2006 ◽  
Vol 69 (1) ◽  
pp. 185-190 ◽  
Author(s):  
HIPÓLITO GÓMEZ-COUSO ◽  
FERNANDO MÉNDEZ-HERMIDA ◽  
JOSÉ ANTONIO CASTRO-HERMIDA ◽  
ELVIRA ARES-MAZÉS

Cryptosporidium contamination was evaluated in areas in Galicia (northwestern Spain) where bivalve molluscs are harvested. Galicia is the main mussel-producing region in Europe. Data were collected on water contamination of effluents that are discharged into these areas. Cryptosporidium spp. were detected by immunofluorescence microscopy and molecular methods in 71% of the river water samples (n = 7), 64% of raw sewage samples (n = 11), 50% of effluents from wastewater treatment plants (n = 16), and 29.3% of the mussel samples (Mytilus galloprovincialis, n = 184). Cryptosporidium parvum was identified in all samples of contaminated mussels, Cryptosporidium muris was found in three samples of effluent from wastewater treatment plants, and Cryptosporidium baileyi was found in a sample of raw sewage. Further studies are needed to determine the parasitological quality of water in these shellfish harvesting and recreational areas. Cryptosporidium could be a public health risk from consumption of raw or undercooked contaminated molluscs and use of contaminated waters for recreational purposes.

2014 ◽  
Vol 69 (6) ◽  
pp. 1289-1297 ◽  
Author(s):  
I. Irizar ◽  
S. Beltrán ◽  
G. Urchegui ◽  
G. Izko ◽  
O. Fernández ◽  
...  

Although often perceived as tools for use by scientists, mathematical modelling and simulation become indispensable when control engineers have to design controllers for real-life wastewater treatment plants (WWTPs). Nonetheless, the design of effective controllers in the wastewater domain using simulations requires effects, such as the nonlinearity of actuators, the time response of sensors, plant model uncertainties, etc. to have been reproduced beforehand. Otherwise, control solutions verified by simulation can completely underperform under real conditions. This study demonstrates that, when all the above effects are included at the outset, a systematic use of simulations guarantees high quality controllers in a relatively short period of time. The above is exemplified through the Mekolalde WWTP, where a comprehensive simulation study was conducted in order to develop a control product for nitrogen removal. Since its activation in May 2011, the designed controller has been permanently working in the plant which, from this time onwards, has experienced significant improvements in the quality of water discharges combined with a lower utilization of electricity for wastewater treatment.


1996 ◽  
Vol 33 (1) ◽  
pp. 81-87
Author(s):  
L. Van Vooren ◽  
P. Willems ◽  
J. P. Ottoy ◽  
G. C. Vansteenkiste ◽  
W. Verstraete

The use of an automatic on-line titration unit for monitoring the effluent quality of wastewater plants is presented. Buffer capacity curves of different effluent types were studied and validation results are presented for both domestic and industrial full-scale wastewater treatment plants. Ammonium and ortho-phosphate monitoring of the effluent were established by using a simple titration device, connected to a data-interpretation unit. The use of this sensor as the activator of an effluent quality proportional sampler is discussed.


1993 ◽  
Vol 28 (11-12) ◽  
pp. 257-261
Author(s):  
M. Truett Garrett ◽  
Zaki Ahmad ◽  
Shelly Young

The recent requirements by U.S.E.P.A. for dechlorination and biomonitoring have increased the importance of automatic control of effluent chlorination in wastewater treatment plants. Difficulties with the Ziegler-Nichols controller tuning procedure were reported at the Kyoto Workshop, 1990. Problems are caused by the noise of incomplete mixing, a long time constant, and the disturbances of changing flow and chlorine demand. The Astrom-Hagglund relay feedback procedure provides acceptable control while data is logged to determine the controller constants. Experiences in using the procedure in existing facilities (not redesigning the mixing point) and the quality of control are presented.


Vestnik MGSU ◽  
2019 ◽  
pp. 589-602 ◽  
Author(s):  
Tran Ha Quan ◽  
Elena S. Gogina

Introduction. Vietnamese urban municipal wastewater treatment plants are mainly of aeration-type facilities. Nowadays, an aeration-type plant, the Sequencing Batch Reactor (SBR), is widely applied and possesses a number of advantages over traditional systems with suspended activated sludge. Advantages of the SBR are mainly concluded in simplicity of operation, occupied area and cost. There is a number of problems at the wastewater treatment plants; they are connected with supplying only a half of wastewater design amount for the treatment as well as with quality of the purified water that must satisfy requirements of the Vietnamese discharge standard, the Standard A. Therefore, reconstruction and modification of the SBR is the major challenger to ensure the sustained development of large Vietnamese cities and maintenance of ecological balance. Materials and methods. To enhance the efficiency of wastewater purification in the SBR, the experiments were set on reactor reconstruction and modification by two directions: (1) Technological method, i.e. applying the Biochip 25 biocarrier, and (2) Operation method, i.e. adding the anoxic phase in reactor operation cycle. Laboratory tests were conducted for each of the directions, including comparison of a typical reactor with the modified one. Results. The study resulted in obtaining an optimal amount of the BioChip biocarrier material (10 to 20 %) that increased efficiency of wastewater purification by 10 to 20 %. In addition to this, when creating an anoxic phase of the operation cycle, efficiency of nitrogen removal increased by 20 %. When the denitrification occurs under the anoxic conditions, it contributes to stabilization of ammonium nitrogen removal for daily nitrogen loading in reactor of 0.3 to 0.8 TKN kg/sludge kg. Conclusions. The suggested technology provides the quality of treated water corresponding with the Vietnamese Standard A requirements. At the present, it is planned to proceed with the experiment on the base of Vietnamese semi-industrial plant for research and appraisal of the SBR reconstruction and modification method. Acknowledgements. The authors are grateful to AKVA Control company in Samara for granted biocarrier Mutag BioChip 25 and to Associate Professor Tran Van Quang and his students, Nguyen Ngoc Phuong and Truong Quoc Dai, of Environment Protect Research Center, Danang University for support of the experiment.


2018 ◽  
Vol 51 (18) ◽  
pp. 880-885 ◽  
Author(s):  
C.E. Robles-Rodriguez ◽  
J. Bernier ◽  
V. Rocher ◽  
D. Dochain

2003 ◽  
Vol 48 (2) ◽  
pp. 373-380 ◽  
Author(s):  
G. Schumacher ◽  
I. Sekoulov

In wastewater ponds, bacteria numbers decrease considerably in the case of raised algae concentrations in the effluent. This shows that algae have a high potential for bacteria reduction in wastewater. Simultaneously, algae remove nutrients from the water for the formation of biomass. However, suspended algae also cause a high secondary pollution in the effluent of wastewater treatment plants. By using attached algae, as they are frequently observed as an algal biofilm in the effluent of wastewater treatment plants, the problem of separation of algae and water can be avoided. Furthermore, the algae can be removed simply from the water. In this study the possibilities for bacteria reduction and nutrient removal were examined with the aid of an algal biofilm. The results show that an algal biofilm process can be used for cases where small amounts of wastewater should be treated and a high quality of the effluent should be attained.


2019 ◽  
Vol 12 (1) ◽  
pp. 34-40
Author(s):  
Kristína Lépesová ◽  
Monika Krahulcová ◽  
Tomáš Mackuľak ◽  
Lucia Bírošová

Abstract Subinhibitory concentrations of antibiotics and biocides in wastewaters and sewage sludge have a great impact on the development of antibiotic resistance and its spread among bacteria. The aim of this work was to determine the occurrence of coliform bacteria and enterococci resistant to biocide triclosan in samples of sewage sludge. Subsequently, isolated strains of coliform bacteria were identified and characterized in terms of their antibiotic susceptibility and ability to form a biofilm. Occurrence of the studied bacteria was monitored in three samples of stabilized sludge from three different wastewater treatment plants (Vrakuňa, Petržalka, and Senec). The number of triclosan-resistant coliforms was the highest in the sludge sample from the wastewater treatment plant in Senec and the lowest in the sludge sample from the wastewater treatment plant in Petržalka. Triclosan-resistant Enterococcus spp. were not found in any sample of stabilized sludge. Most isolates were identified as Citrobacter freundii and Serratia spp. Triclosan-resistant isolates showed also resistance to antibiotics and the majority of them were strong biofilm producers.


2019 ◽  
Vol 7 (2) ◽  
pp. 68
Author(s):  
Wahyuni Wahyuni ◽  
Supriyono Eko Wardoyo ◽  
Ridha Arizal

The Quality of Well Water around Final Garbage Dump (FGD)  Rawa Kucing, Tangerang, IndonesiaFGD Rawa Kucing is located at Sultan Iskandar Muda Street, Kedaung Wetan, Neglasari, Tangerang, Banten, Indonesia. It serves 1000 tons of garbage per day from 13 districts in Tangerang. The volume of garbage in Kota Tangerang increases from 1,212,264 m3 in 2008 to 4,590,724 m3in 2012.Well water is the main source of water for people around the FGD RawaKucing. They use well water for bath, wash,  and toilet (BWT) and other needs. Garbage decomposition which makes pollution around FGD Rawa Kucing can accur in air, water, and soil. Waste accurs in water and soil caused by leachate. Leachate can easily  spread through rainwater runoff and it absorbs to the ground and polluting it including well water around it. Contaminated well water can decrease the quality of water physically, chemically, and microbiologically.Groundwater samples taken from residents' well water around FGD Rawa Kucing  and they were represented by three groups which have distance 100 m - 3 km from FGD. Each group consisted of three samples which were taken from well water having depths between 8-18 m. The examination of the quality of well water should be made in accordance with the Regulation of the Minister of Health of the Republic of Indonesia No.416/MENKE /PER/IX/1990 on the Conditions and Control of the Quality of Clean Water and Quality Regulation of the Minister of Health of the Republic of Indonesia No. 492/MENKES/PER/IV/ on Requirements and Quality Control of Drinking Water.The quality of well water around FGD Rawa Kucing showed that there were the decreased quality water after testing with several parameter tests. There were six examination parameters which concentrate on exceeding the required quality standards that of TDS (1600-1764 mg/L), Nitrates (10.5-37.8 mg/L), Ammonia (3.50-66.21 mg/L), Iron (1.054-7.063 mg/L), Manganese (1.085-10.130 mg/L), and Total Coliform (80-130 colonies/100 mL).Keywords : Well water, leachate, TPAS, pollution, water qualityABSTRAKTPAS Rawa Kucing berada di Jalan Sultan Iskandar Muda Kelurahan Kedaung Wetan, Kecamatan Neglasari, Kota Tangerang, Banten dan mengangkut 1000 ton sampah/hari dari 13 kecamatan.Volume sampah di Kota Tangerang terus meningkat dari tahun 2008 sebesar 1.212.264 m3 sampai pada tahun 2012 telah mencapai 4.590.724 m3. Air sumur merupakan sumber air utama bagi masyarakat sekitar TPAS, karena hampir semua kebutuhan air dipenuhi dari air sumur yaitu untuk Mandi Cuci Kakus (MCK) dan kebutuhan lainnya. Pencemaran akibat dekomposisi sampah dapat terjadi di udara, dapat pula terjadi pada air dan tanah yang disebabkan oleh adanya rembesan air lindi. Lindi tersebut mudah disebarkan melalui limpasan air hujan dan meresap mencemari air tanah termasukair sumur yang ada di sekitarnya. Air sumur yang terkontaminasi lindi berakibat terjadinya penurunan kualitas air secara fisik, kimia, dan mikrobiologi. Air tanah sampelyang diambil berasal dari sumur penduduk yang berada di sekitar TPAS Rawa Kucing diwakili oleh 3 pengelompokkan dengan jarak 100 m – 3 km dari TPAS. Setiap kelompok terdiri dari 3 sumur pompa dengan kedalaman sumur antara 8 – 18 m. Pemeriksaan kualitas air sumur dilakukan  mengacu pada Peraturan Menteri Kesehatan Republik Indonesia Nomor 416/MENKES/PER/IX/1990 tentang Syarat-syarat dan Pengawasan Kualitas Air Bersih dan Peraturan MenteriKesehatan Republik Indonesia Nomor 492/MENKES/PER/IV/2010 tentang Syarat-syaratdan Pengawasan Kualitas Air minum.  Kualitas air sumur masyarakat di sekitar TPAS Rawa Kucing mengalami penurunan setelah dilakukan pengujian terhadap beberapa parameter. Ada 6 parameter pemeriksaan yang mempunyai konsentrasi  melebihi baku mutu yang dipersyaratkan yaitu TDS (1600-1764 mg/L), Nitrat (10,5-37,8 mg/L), Amonia (3,50-66,21 mg/L), Besi (1,054-7,063 mg/L), Mangan (1,085-10,130 mg/L), dan Total Coliform (80-130 koloni/100 mL).Kata kunci : Air sumur, air lindi, TPAS, pencemaran, kualitas air


2021 ◽  
Vol 6 (1) ◽  
pp. 28-32
Author(s):  
Valeriia Lytvynenko ◽  
◽  
Alina Dychko ◽  

Wastewater contaminated with hexamethylenediamine (HMD), which is discharged into natural reservoirs, causes damage and loss of hydrobionts, worsens the quality of water which becomes unsuitable for use. For wastewater treatment from HMD, the possibility of applying bacterial cultures-destructors which use the HMD as a nutrition source is considered.


Sign in / Sign up

Export Citation Format

Share Document