scholarly journals Evaluation of Embrace WetBond and Helioseal-F sealant retention with and without a Self-etch adhesive: A 12 month follow-up

2021 ◽  
pp. e1189-e1195
Author(s):  
G. Mathew ◽  
T. Jayakaran ◽  
H. Ramkumar ◽  
S. Dakshinamoorthy ◽  
S. Paulindraraj ◽  
...  
Keyword(s):  



2021 ◽  
pp. 1-7
Author(s):  
Jiand Malik Baloch ◽  
Muhammad Adeel Ahmed ◽  
Azeem Ul Yaqin Syed ◽  
Muhammad Zohaib Younus ◽  
Muhammad Owais Nasim ◽  
...  

BACKGROUND: Dental caries is one of the most common diseases around the world. The newly erupted permanent posterior teeth are at great risk due to the complex occlusal morphology of pits and fissures, infraocclusion and incomplete maturation of enamel. Pit and fissure sealants are the treatment of choice in such conditions. OBJECTIVES: To compare the successful outcome of pit and fissure sealants bonded with etch-and-rinse adhesive system and self-etch adhesive systems in newly erupted permanent first molars. METHODS: This randomized clinical trial was conducted at the Fatimah Jinnah Dental Hospital from June 2017 to May 2019. Children aged between 6 to 9 years who fulfilled the inclusion criteria were recruited for this study after parents’ consent. Patients were randomly divided into two groups by the lottery method. Thirty patients with 60 first molar teeth in Group A were treated with etch-and-rinse adhesive system, while the other thirty patients with 60 first molar teeth in Group B were treated with self-etch adhesive system. After adhesive placement, all children received the same fissure sealants in newly erupted maxillary and mandibular permanent first molar. Each group was clinically evaluated at 6 and 12 months follow-up visit. Modified United States Public Health Service (USPHS) criteria were used for direct clinical evaluation of successful outcomes such as sealant retention and marginal discoloration. RESULTS: Successful outcome was statistically significant in Group B compared to Group A (60% vs. 30% p= 0.020) at 12 months follow-up. Stratification analysis was performed with respect to age in which a successful outcome was not significant (p= 0.43) between groups for 6 to 7 years of age, while it was significant (p= 0.012) between groups in 8 to 9 years of age children. CONCLUSION: Self-etch adhesive system is better than etch-and-rinse adhesive system in terms of long-term sealant retention. In addition, the bonding procedure is simple with relatively short clinical application time therefore it would offer great benefit to clinicians in treating pediatric patients.



2016 ◽  
Vol 27 (3) ◽  
pp. 359-362 ◽  
Author(s):  
Rudá França Moreira ◽  
Rossana Gomes Figueiredo ◽  
Henrique Eduardo Oliveira ◽  
Ana Christina Lamosa da Fonseca ◽  
Mauro Sayão de Miranda

Abstract The aim of this paper was to describe a clinical case of immediate dental desensitization using a self-etch adhesive system in an adolescent patient diagnosed with amelogenesis imperfecta (AI). AI was associated with severe tooth sensitivity, treated by the application of a universal adhesive system for desensitization of the teeth affected by AI. Reduction of tooth sensitivity was assessed using a visual analog scale during all reevaluations. The technique was effective for reducing tooth sensitivity. It was concluded that the adhesive system for tooth desensitization had an immediate effect and maintained its effectiveness during a 12-month follow-up period.



2009 ◽  
Vol 34 (5) ◽  
pp. 516-523 ◽  
Author(s):  
A. Aykor ◽  
E. Ozel

Clinical Relevance Total-etch (Scotchbond Multi-Purpose Plus) and two-step self-etch (AdheSE) adhesive systems were successful in terms of marginal adaptation, cavosurface discoloration, secondary caries, postoperative sensitivity, satisfaction with restoration shade and gingival tissue response in a five-year follow-up.



2018 ◽  
Vol 43 (4) ◽  
pp. 362-371 ◽  
Author(s):  
AR Yazici ◽  
E Ozturk Bayazit ◽  
ZB Kutuk ◽  
G Ozgunaltay ◽  
E Ergin ◽  
...  

SUMMARY The purpose of this study was to evaluate the retention rates of a fissure sealant placed using different adhesive protocols over 24 months. Twenty-four subjects with no restorations or caries received fissure sealants (Clinpro Sealant, 3M ESPE) placed using different adhesive protocols. A total of 292 sealants were placed as follows by two previously calibrated dentists using a table of random numbers (n=73): group I, acid-etch/without adhesive; group II, with a self-etch adhesive (Adper Easy Bond, 3M ESPE); group III, with an etch-and-rinse adhesive (Adper Single Bond 2, 3M ESPE); group IV, with acid + self-etch adhesive (Adper Easy Bond). Two other calibrated examiners independently evaluated the sealants at baseline and at six-, 12-, 18-, and 24-month recalls. Each sealant was evaluated in terms of caries formation being present or absent and retention using the following criteria: 1 = total retention, 2 = partial loss, and 3 = total loss. Pearson's χ2 test was used to evaluate differences in retention rates among the sealants for each evaluation period. At the end of 24 months, total retention rates were 57.5%, 27.4%, 84.9%, and 76.7% in the acid-etch, self-etch adhesive, etch-and-rinse adhesive, and acid + self-etch adhesive groups, respectively. Although there were no statistically significant differences between the retention rates among the adhesive protocols at 6 months (p=0.684), significant differences were observed at the 12-, 18-, and 24-month evaluations. At 24 months, the lowest retention rates were observed in the self-etch group (p<0.05). No caries development was observed in any of the groups. The retention rate of sealants placed using self-etch adhesive was poor compared with the other groups.



2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Samar Hatem Abuzinadah ◽  
Abdulrahman Jafar Alhaddad

AbstractDentinal hypersensitivity (DH) is a condition that causes patient discomfort. To evaluate the clinical efficacy of Gluma, fluoride varnish and Tetric N-Bond self-etch system in relieving DH immediately and over 30 days following a single topical application. The present randomized clinical trial was conducted on 55 patients with an age range 20–49 years. 70 teeth in total were incorporated and randomly assigned to the three groups. Parameters examined were: Tactile, air blast, and cold stimuli. VAS was used to assess tactile stimulus whereas the Schiff Cold Scale for air blast and cold stimuli. DH was evaluated immediately, at two weeks and 1 month follow up. Gluma showed a statistically significant reduction in DH scores over other materials. It was concluded that Gluma have statistically significant results over other materials in relieving DH immediately and over 30 days following a single topical application.Trial Registration: Clinical Trials.gov Identifier: NCT04351412, King Abdulaziz University Protocol Record 129-09-19. Registered 17 April 2020 – Retrospectively registered. http://ClinicalTrials.gov/NCT04351412.



2011 ◽  
Vol 36 (1) ◽  
pp. 112-115 ◽  
Author(s):  
E. Ozel ◽  
M. Karapinar-Kazandag ◽  
M. Soyman ◽  
G. Bayirli

Clinical Relevance The teeth in this report were restored with a two-step self-etch adhesive system and a microhybrid resin composite. The teeth present with an excellent clinical performance and patient acceptance at the end of a six-year recall.



2015 ◽  
Vol 63 (3) ◽  
pp. 301-308
Author(s):  
Alline FRAY ◽  
Thaís Manzano PARISOTTO ◽  
Gabriela Azevedo de Vasconcelos Cunha BONINI ◽  
Regina Maura Coli SIEGL ◽  
José Carlos Pettorossi IMPARATO

Objective: The aim of this study was to evaluate the retention of glass ionomer sealant, Vitro Molar(r) (DFL) and Ketac Molar Easy Mix(r) (3 m ESPE) as pit and fissure sealants on first permanent molars, fully or partially erupted. Methods: The study sample consisted of 412 molars, among 110 children. The sealant retention was evaluated after 6 months of the application. Results: The results were collected through digital photographs and the retention results were assessed by the following System: score 0 - total retention; score 1 - sealant present in more than 50% of the pit and fissure system; score 2 - sealant present in less than 50% of the pit and fissure system; score 3 - missing sealant. Regarding the presence of the sealants in less than 50% of the occlusal surface, lower percentages were found for the two materials used as follows: score score 2 - Vitro Molar(r) (9,52% examiner 1 and 11.9% examiner 2) and score 2 - Ketac Molar Easy Mix(r)(9.52% examiner 1 and 10.71% examiner 2). Approximately 90% of the teeth sealed with Ketac Molar Easy Mix(r)or Vitro Molar(r) presented total loss (score 3). Thus, there was no statistical difference between the materials and between the examiners (p>0.05). Conclusion: Therefore it was concluded that the sealant retention in the studied population was not satisfactory for any of the materials used.



2019 ◽  
Vol 42 ◽  
Author(s):  
John P. A. Ioannidis

AbstractNeurobiology-based interventions for mental diseases and searches for useful biomarkers of treatment response have largely failed. Clinical trials should assess interventions related to environmental and social stressors, with long-term follow-up; social rather than biological endpoints; personalized outcomes; and suitable cluster, adaptive, and n-of-1 designs. Labor, education, financial, and other social/political decisions should be evaluated for their impacts on mental disease.



1999 ◽  
Vol 173 ◽  
pp. 189-192
Author(s):  
J. Tichá ◽  
M. Tichý ◽  
Z. Moravec

AbstractA long-term photographic search programme for minor planets was begun at the Kleť Observatory at the end of seventies using a 0.63-m Maksutov telescope, but with insufficient respect for long-arc follow-up astrometry. More than two thousand provisional designations were given to new Kleť discoveries. Since 1993 targeted follow-up astrometry of Kleť candidates has been performed with a 0.57-m reflector equipped with a CCD camera, and reliable orbits for many previous Kleť discoveries have been determined. The photographic programme results in more than 350 numbered minor planets credited to Kleť, one of the world's most prolific discovery sites. Nearly 50 per cent of them were numbered as a consequence of CCD follow-up observations since 1994.This brief summary describes the results of this Kleť photographic minor planet survey between 1977 and 1996. The majority of the Kleť photographic discoveries are main belt asteroids, but two Amor type asteroids and one Trojan have been found.



Sign in / Sign up

Export Citation Format

Share Document