The Turing mechanism and geometric pattern

Author(s):  
John Vandermeer ◽  
Ivette Perfecto
2021 ◽  
Vol 11 (13) ◽  
pp. 5760
Author(s):  
Sung-Yong Kim ◽  
Baek-Gyu Choi ◽  
Gwang-Won Oh ◽  
Chan-Jung Kim ◽  
Young-Seok Jung ◽  
...  

For an engineering feasibility study, we studied a simple design to improve NCSS (nanocarbon composite strain sensor) sensitivity by using its geometric pattern at a macro scale. We fabricated bulk- and grid-type sensors with different filler content weights (wt.%) and different sensor lengths and investigated their sensitivity characteristics. We also proposed a unit gauge factor model of NCSS to find a correlation between sensor length and its sensitivity. NCSS sensitivity was improved proportional to its length incremental ratio and we were able to achieve better linear and consistent data from the grid type than the bulk type one. We conclude that the longer sensor length results in a larger change of resistance due to its piezoresistive unit summation and that sensor geometric pattern design is one of the important issues for axial load and deformation measurement.


2021 ◽  
Vol 3 (2) ◽  
Author(s):  
Sayat Mimar ◽  
Mariamo Mussa Juane ◽  
Jorge Mira ◽  
Juyong Park ◽  
Alberto P. Muñuzuri ◽  
...  

2017 ◽  
Vol 19 (6) ◽  
pp. 1725-1743
Author(s):  
Jaydeep Patel ◽  
Vimal Savsani ◽  
Vivek Patel ◽  
Rajesh Patel

Processes ◽  
2020 ◽  
Vol 9 (1) ◽  
pp. 44
Author(s):  
Yi Ge ◽  
Zhenbo Tong ◽  
Renjie Li ◽  
Fen Huang ◽  
Jiaqi Yu

Respimat®Soft MistTM is a newly developed spray inhaler. Different from traditional nebulizers, metered-dose inhalers, and dry powder inhalers, this new type of inhaler can produce aerosols with long duration, relatively slow speed, and a high content of fine particles. Investigating the effect of the key geometric parameters of the device on the atomization is of great significance for generic product development and inhaler optimization. In this paper, a laser high-speed camera experimental platform is built, and important parameters such as the geometric pattern and particle size distribution of the Respimat®Soft MistTM are measured. Computational fluid dynamics (CFD) and the volume of fluid method coupled with the Shear Stress Transport (SST) k-ω turbulence model are applied to simulate the key geometric parameters of the device. The effects of geometric parameters on the spray velocity distribution and geometric pattern are obtained. The angle of flow collision, the sphere size of the central divider and the length and width of the flow channel show significant impacts on the spray atomization.


2014 ◽  
Vol 28 (S1) ◽  
Author(s):  
Paula Azevedo ◽  
Andrea Batista ◽  
Antonio Baccaro ◽  
Karina Narimatsu ◽  
Pamela Modesto ◽  
...  

2013 ◽  
Vol 7 ◽  
pp. CMC.S12727 ◽  
Author(s):  
Rasaaq A. Adebayo ◽  
Olaniyi J. Bamikole ◽  
Michael O. Balogun ◽  
Anthony O. Akintomide ◽  
Victor O. Adeyeye ◽  
...  

Left ventricular (LV) hypertrophy is an important predictor of morbidity and mortality in hypertensive patients, and its geometric pattern is a useful determinant of severity and prognosis of heart disease. Studies on LV geometric pattern involving large number of Nigerian hypertensive patients are limited. We examined the LV geometric pattern in hypertensive patients seen in our echocardiographic laboratory. A two-dimensional, pulsed, continuous and color flow Doppler echocardiographic evaluation of 1020 consecutive hypertensive patients aged between 18 and 91 years was conducted over an 8-year period. LV geometric patterns were determined using the relationship between the relative wall thickness and LV mass index. Four patterns of LV geometry were found: 237 (23.2%) patients had concentric hypertrophy, 109 (10.7%) had eccentric hypertrophy, 488 (47.8%) had concentric remodeling, and 186 (18.2%) had normal geometry. Patients with concentric hypertrophy were significantly older in age, and had significantly higher systolic blood pressure (BP), diastolic BP, and pulse pressure than those with normal geometry. Systolic function index in patients with eccentric hypertrophy was significantly lower than in other geometric patterns. Doppler echocardiographic parameters showed some diastolic dysfunction in hypertensive patients with abnormal LV geometry. Concentric remodeling was the most common LV geometric pattern observed in our hypertensive patients, followed by concentric hypertrophy and eccentric hypertrophy. Patients with concentric hypertrophy were older than those with other geometric patterns. LV systolic function was significantly lower in patients with eccentric hypertrophy and some degree of diastolic dysfunction were present in patients with abnormal LV geometry.


Sign in / Sign up

Export Citation Format

Share Document