scholarly journals SPACE VECTOR BASED THREE PHASE GRID CONNECTED PHOTOVOLTAIC SYSTEM

Author(s):  
T. NARASIMHA PRASAD ◽  
V. LAKSHMI DEVI

Solar energy has become a very potential new energy; Connected directly with grid-connected photovoltaic (PV) systems does not require bulk and lossy battery. Distributed generation and on-site supply of PV system reduces losses of transmission and distribution, and mitigates environment pollution. This paper establishes a Dynamic model of grid-connected PV system by Matlab/Simulink with d-and q-axis as coordinates which is synchronously rotating with the grid voltage to reflect the characteristics of the system accurately. Based on the accurate modeling system, optimum control and fault analysis are studied. The simulation and analysis verify the effectiveness of the proposed algorithm, and demonstrate that the proposed control system has good static performance.

2013 ◽  
Vol 2013 ◽  
pp. 1-9 ◽  
Author(s):  
Yongheng Yang ◽  
Frede Blaabjerg

The progressive growing of single-phase photovoltaic (PV) systems makes the Distribution System Operators (DSOs) update or revise the existing grid codes in order to guarantee the availability, quality, and reliability of the electrical system. It is expected that the future PV systems connected to the low-voltage grid will be more active with functionalities of low-voltage ride-through (LVRT) and the grid support capability, which is not the case today. In this paper, the operation principle is demonstrated for a single-phase grid-connected PV system in a low-voltage ride-through operation in order to map future challenges. The system is verified by simulations and experiments. Test results show that the proposed power control method is effective and the single-phase PV inverters connected to low-voltage networks are ready to provide grid support and ride-through voltage fault capability with a satisfactory performance based on the grid requirements for three-phase renewable energy systems.


2013 ◽  
Vol 135 (2) ◽  
Author(s):  
Peyman Naderi

Distributed generation (DG) using a parallel battery pack with photovoltaic (PV) system has been presented in this brief. Considering a two level inverter and a three phase transformer, a local load will be supplied by the DG and connected to a power grid. The DG has been connected to the high voltage network via a filter and a distribution power station. A nero-fuzzy network has been designed for the estimation of maximum power ability of PV and the connected dc/dc converter has been controlled relatively. So, the power management between the PV system and the battery pack can be confirmed. On the other hand, another controller has been designed for control of transferred power between the power network and the DG system that can control the battery pack power indirectly. Finally, a series of simulation results show the effectiveness of proposed method for some various conditions.


2013 ◽  
Vol 16 (4) ◽  
pp. 19-32
Author(s):  
Dzung Quoc Pham ◽  
Vu Truong Dan Nguyen ◽  
Khoa Dinh Le ◽  
Anh Bao Nguyen ◽  
Diep Chi Le

Single-stage topology and the maximum power point tracking (MPPT) algorithm have advantages such as simple configuration and high efficiency in grid-connected photovoltaic (PV) systems. In conventional systems, current and voltage sensors of PV system are normally used for MPPT. This paper presents a modified control algorithm for the single-stage three-phase grid-connected PV system without PV current sensor with a variable step MPP-tracker. This algorithm is not derived from complex state equations and is not dependent on any circuit parameters. It simply calculates the output power of the inverter to replace the input power of the PV systems in the MPPT algorithm. The modified algorithm is simulated by using Matlab/Simulink software and implemented in the experimental prototype. With the single-stage configuration and PV current sensorless method, the prototype is suitable for lowcost high efficient implementation in the practice.


2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Mohannad Jabbar Mnati ◽  
Dimitar V. Bozalakov ◽  
Alex Van den Bossche

Nowadays, most three-phase, “off the shelf” inverters use electrolytic capacitors at the DC bus to provide short term energy storage. However, this has a direct impact on inverter lifetime and the total cost of the photovoltaic system. This article proposes a novel control strategy called a 120° bus clamped PWM (120BCM). The 120BCM modulates the DC bus and uses a smaller DC bus capacitor value, which is typical for film capacitors. Hence, the inverter lifetime can be increased up to the operational lifetime of the photovoltaic panels. Thus, the total cost of ownership of the PV system will decrease significantly. Furthermore, the proposed 120BCM control strategy modulates only one phase current at a time by using only one leg to perform the modulation. As a result, switching losses are significantly reduced. The full system setup is designed and presented in this paper with some practical results.


Energies ◽  
2019 ◽  
Vol 12 (15) ◽  
pp. 2899 ◽  
Author(s):  
Alexis B. Rey-Boué ◽  
N. F. Guerrero-Rodríguez ◽  
Johannes Stöckl ◽  
Thomas I. Strasser

This article deals with the vector control in dq axes of a three-phase grid-connected photovoltaic system with single-stage topology and low-voltage-ride-through capability. The photovoltaic generator is built using an array of several series-parallel Suntech PV modules and is modeled as a Lookup Table (two-dimensional; 2-D). The requirements adopted when grid voltage sags occur are based in both the IEC 61400-21 European normative and the allowed amount of reactive power to be delivered according to the Spanish grid code, which avoids the disconnection of the inverter under grid faults by a limitation in the magnitude of the three-phase output inverter currents. For this, the calculation of the positive- and negative-sequences of the grid voltages is made and a conventional three-phase Phase-Locked Loop is used for the inverter-grid synchronization, allowing the control of the active and reactive powers solely with the dq components of the inverter currents. A detailed enhanced flowchart of the control algorithm with low-voltage-ride-through capability is presented and several simulations and experiments using Matlab/SIMULINK and the Controller Hardware-in-the-Loop simulation technique, respectively, are run for several types of one- and three-phase voltage sags in order to validate its behavior.


Energies ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 3152 ◽  
Author(s):  
Huadian Xu ◽  
Jianhui Su ◽  
Ning Liu ◽  
Yong Shi

Conventional photovoltaic (PV) systems interfaced by grid-connected inverters fail to support the grid and participate in frequency regulation. Furthermore, reduced system inertia as a result of the integration of conventional PV systems may lead to an increased frequency deviation of the grid for contingencies. In this paper, a grid-supporting PV system, which can provide inertia and participate in frequency regulation through virtual synchronous generator (VSG) technology and an energy storage unit, is proposed. The function of supporting the grid is implemented in a practical PV system through using the presented control scheme and topology. Compared with the conventional PV system, the grid-supporting PV system, behaving as an inertial voltage source like synchronous generators, has the capability of participating in frequency regulation and providing inertia. Moreover, the proposed PV system can mitigate autonomously the power imbalance between generation and consumption, filter the PV power, and operate without the phase-locked loop after initial synchronization. Performance analysis is conducted and the stability constraint is theoretically formulated. The novel PV system is validated on a modified CIGRE benchmark under different cases, being compared with the conventional PV system. The verifications demonstrate the grid support functions of the proposed PV system.


Author(s):  
Mohammed Bouzidi ◽  
Abdelkader Harrouz ◽  
Tadj Mohammed ◽  
Smail Mansouri

<p>The inverter is the principal part of the photovoltaic (PV) systems that assures the direct current/alternating current (DC/AC) conversion (PV array is connected directly to an inverter that converts the DC energy produced by the PV array into AC energy that is directly connected to the electric utility). In this paper, we present a simple method for detecting faults that occurred during the operation of the inverter. These types of faults or faults affect the efficiency and cost-effectiveness of the photovoltaic system, especially the inverter, which is the main component responsible for the conversion. Hence, we have shown first the faults obtained in the case of the short circuit. Second, the open circuit failure is studied. The results demonstrate the efficacy of the proposed method. Good monitoring and detection of faults in the inverter can increase the system's reliability and decrease the undesirable faults that appeared in the PV system. The system behavior is tested under variable parameters and conditions using MATLAB/Simulink.</p>


2018 ◽  
Vol 18 (1) ◽  
pp. 35 ◽  
Author(s):  
Rofiatul Izah ◽  
Subiyanto Subiyanto ◽  
Dhidik Prastiyanto

Synchronous Reference Frame Phase Locked Loop (SRF PLL) has been widely used for synchronization three-phase grid-connected photovoltaic (PV) system. On the grid fault, SRF PLL distorted by negative sequence component and grid harmonic that caused an error in estimating parameter because of ripple and oscillation. This work combined SRF PLL with Dual Second Order Generalized Integrator (DSOGI) and filter to minimize ripple and minimize oscillation in the phase estimation and frequency estimation. DSOGI was used for filtering and obtaining the 90o shifted versions from the vαβ signals. These signals (vαβ) were generated from three phase grid voltage signal using Clarke transform. The vαβ signal was the inputs to the positive-sequence calculator (PSC). The positive-sequence vαβ was transformed to the dq synchronous reference frame and became an input to SRF-PLL to create the estimation frequency. This estimation frequency from SRF PLL was filtered by the low-pass filter to decrease grid harmonic. Moreover, the output of low-pass filter was a frequency adaptive. The performance of DSOGI PLL with filter is compared with DSOGI PLL, SRF PLL, and IEEE standard 1547(TM)-2003. The improvement of DSOGI PLL with filter gave better performances than DSOGI PLL and SRF PLLbecause it minimized ripples and oscillations in the phase and frequency estimations.


2018 ◽  
Vol 225 ◽  
pp. 04004
Author(s):  
Tan Dei Han ◽  
Mohamad Rosman M. Razif ◽  
Shaharin A. Sulaiman

Solar photovoltaic (PV) systems has the potential of supplying infinite electricity from renewable energy to rural areas around Malaysia. Various preterm failures happening frequently on the system lead to its drop in efficiency and breakdown. Lack of studies on the system in Malaysia hinders the development in terms of operation and maintenance. There is no proper documentation relevant to the premature failure of the system in Malaysia. The main objective of this project is to study the nature of premature failure of stand-alone solar photovoltaic system in Malaysia in order to improve the operation and maintenance of the system. The present study would provide reference for proper planning on operation and maintenance of the PV system. The study was conducted base on expert’s input and extensive literature survey. FMEA method and ISM approach are applied to analyze the data collected. Poor cooling system have the highest risk priority number. Poor workmanship is the least depending factor for premature failure to happen thus requires most attention. Highest driving force of premature failure is poor monitoring and maintenance. More focus should be given to these premature failure during the planning for operation and maintenance due to its severity and impact.


2011 ◽  
Vol 356-360 ◽  
pp. 2393-2398
Author(s):  
Qi Qi Wei ◽  
Bei Yue Tan

photovoltaic system, optimum tilted angle, siphon principle, water treatment Abstract. Based on the recent research at home and abroad and the local meteorological data, this study aims to determine the optimum tilt angle of the solar-cell array surface and the best month on the system to achieve the optimal design of PV system. Full mechanical automatic control system is designed by using lever principle and siphon principle to realize the purpose of all-day and maintenance-free operational situation. It can replace the motor control system and at the same time,enjoys reliability, low cost, long life and energy conservation. The indoor and local river data of the experiment shows that this system has an evident effect on water decontamination. Furthermore, comparing with traditional aeration system. It has many advantages, for instance, it can save more than 20 thousand and carbon emission can be reduced by 683 ton and other aspects.