The Effect of CRAMS Trauma Score on Improving The Success Rate of Emergency Treatment

2021 ◽  
1970 ◽  
Vol 1 (1) ◽  
Author(s):  
Kang Yuehua

Objective: To explore the impact of human nursing on emergency success rate and satisfaction in emergency department nursing. Methods: 146 cases of emergency patients were collected from February 2015 to July 2016 in our hospital. The patients were randomly divided into control group and experimental group (73 cases). The patients in the control group were treated by routine nursing method. The patients in the experimental group nursing intervention was performed on the basis of humanized care in the control group, and the success rate and satisfaction of the two groups were observed. Results: The success rate of emergency treatment (93.2%) in the experimental group was significantly higher than that in the control group (79.5%), the difference was statistically significant (P < 0.05).After the nursing group, the satisfaction rate 91.8%) was significantly higher than that of the control group (65.8%), which was statistically significant (P < 0.05). Conclusion: Human care in emergency department nursing can effectively improve the success rate of emergency and patient satisfaction.


2007 ◽  
Vol 177 (4S) ◽  
pp. 440-440
Author(s):  
Kathleen C. Kobashi ◽  
Fred E. Govier ◽  
Tanya M. Nazemi
Keyword(s):  

2004 ◽  
Vol 171 (4S) ◽  
pp. 7-7
Author(s):  
Hansjoerg Danuser ◽  
Eduard Dobry ◽  
Fiona C. Burkhard ◽  
Werner W. Hochreiter ◽  
Urs E. Studer

VASA ◽  
2002 ◽  
Vol 31 (1) ◽  
pp. 36-42 ◽  
Author(s):  
. Bucek ◽  
Hudak ◽  
Schnürer ◽  
Ahmadi ◽  
Wolfram ◽  
...  

Background: We investigated the long-term clinical results of percutaneous transluminal angioplasty (PTA) in patients with peripheral arterial occlusive disease (PAOD) and the influence of different parameters on the primary success rate, the rate of complications and the long-term outcome. Patients and methods: We reviewed clinical and hemodynamic follow-up data of 166 consecutive patients treated with PTA in 1987 in our department. Results: PTA improved the clinical situation in 79.4% of patients with iliac lesions and in 88.3% of patients with femoro-popliteal lesions. The clinical stage and ankle brachial index (ABI) post-interventional could be improved significantly (each P < 0,001), the same results were observed at the end of follow-up (each P < 0,001). Major complications occurred in 11 patients (6.6%). The rate of primary clinical long-term success for suprainguinal lesions was 55% and 38% after 5 and 10 years (femoro-popliteal 44% and 33%), respectively, the corresponding data for secondary clinical long-term success were 63% and 56% (60% and 55%). Older age (P = 0,017) and lower ABI pre-interventional (P = 0,019) significantly deteriorated primary clinical long-term success for suprainguinal lesions, while no factor could be identified influencing the outcome of femoro-popliteal lesions significantly. Conclusion: Besides an acceptable success rate with a low rate of severe complications, our results demonstrate favourable long-term clinical results of PTA in patients with PAOD.


VASA ◽  
2011 ◽  
Vol 40 (3) ◽  
pp. 235-240 ◽  
Author(s):  
Krnic ◽  
Sucic

Background: The aim of this study is to report our results in main stem vein closure using the bipolar radiofrequency induced thermotherapy (RFITT) system and the 1064nm Nd:Yag laser. Patients and methods: 44 incompetent main stem veins (37 great saphenous veins, one lesser saphenous vein, and 6 anterior accessory saphenous veins) in 29 patients were treated using RFITT. 53 incompetent main stem veins (45 great saphenous veins, 4 lesser saphenous veins, and 4 anterior accessory saphenous veins) in 43 patients were treated endovenously with 1064 nm Nd:Yag laser. All patients underwent postoperative duplex scanning within a month after procedure, as well as a short interview regarding postoperative discomfort. Results: In main stem veins treated with RFITT, the success rate within the first month was 86,4 % (38 out of 44 veins). Complete failure rate was 13,6 % (6 out of 44 veins). In 53 main stem veins treated by 1064 nm Nd:Yag laser, the success rate was 100 %, consisting of 98,1 % complete success (52/53 veins), and 1,9 % partial success (1/53 veins). None of the patients treated with RFITT experienced postoperative adverse effects, whereas 13/43 (30,2 %) patients treated with laser had to use oral analgesics after the treatment, and 21/43 (48,8 %) patients reported transient skin changes, such as bruising or skin redness. Conclusions: RFITT system was fairly efficient in the short term for closure of main trunk veins, whereas longer term results are still scarce. Postoperative side effects of RFITT were minimal. 1064nm Nd:Yag laser, according to short term results, proved to be very effective for main stem vein closure. Postoperative side effects related to 1064 nm Nd:Yag endovenous laser treatment proved to be minor, transient, and acceptable.


Phlebologie ◽  
2010 ◽  
Vol 39 (02) ◽  
pp. 77-81 ◽  
Author(s):  
A. G. Krasznai ◽  
E. C. M. Bollen ◽  
J. C. van der Kley ◽  
R. J. Th. J. Welten ◽  
G. M. J. M. Welten

SummaryOur aim is to describe the results of a new short stripping technique for the treatment of the incompetent great saphenous vein (GSV) using a new developed surgical device. Patients, methods: 397 patients (498 legs) were treated with the InvisiGrip® Vein Stripper, which removes the GSV through a single groin incision, endovascular cutting and antegrade stripping by inversion. We reported the surgical success rate and postprocedural complications. Results: The mean age was 51 years, 74% were women. The success rate for removal of the GSV was 95%. The 23 failures were half patient related, half device related. In 82% of the strippings, one or two attempts were needed to successfully remove the GSV, which was done by invagination in 80%. Age, gender, BMI ≥30 kg/m2 and male GSV diameter were not associated with the number of attempts. Superficial wound infection, haematoma and temporary saphenous and femoral nerve injury occurred in 6 (1.6%), 0, 3 (0.8%) and 7 (1.9%) patients, respectively. Conclusion: The InvisiGrip® is highly successful for the removal of the GSV using short inverting stripping. Furthermore, it is simple, safe, associated with good cosmetic results and no preoperative selection of patients is necessary.


Sign in / Sign up

Export Citation Format

Share Document