scholarly journals Theoretical Study of Photovoltaic Thermal Integrated Absorption Cooling System under Jordan Climate

Author(s):  
Mohammed Al-Odat

This paper presents a theoretical investigation to simulate the utilization of (PV/T) technology to drive an absorption refrigeration system that is used for air conditioning of a classroom under Jordan climate conditions. The absorption refrigeration cycle uses the hot water from the PV/T collector with an assisted electrical heater as a heat source in the generator. In addition to the capability to utilize the PV/T to supply the building by domestic hot water and electricity if no need to run the refrigeration cycle. This analysis was carried using excel program and theoretical equations for the system. It was found that (PV/T) technology is very useful for thermal applications with high efficiency. Also, absorption refrigeration cycle has a good coefficient of performance because it main ly depends on the thermal energy with low electrical energy consumption to run the pump. Moreover, this system has a short payback period, low energy consumption, low running cost, and minimum environmental impact. The results of this study show that the system needs about (84 m 2 PV/T collectors) to cover 16 tons cooling load.

2019 ◽  
Vol 23 (5 Part B) ◽  
pp. 2995-3001 ◽  
Author(s):  
Andi Balasubramanian ◽  
Venkatesan Jayaraman ◽  
Suresh Sivan ◽  
Mariappan Vairavan

In this study, performance analysis of absorption refrigeration cycle has been carried out under variable power sources namely electrical and thermal energy sources. The triple fluid vapour absorption system was used in this work. The temperatures at each point in the cycle such as generator, absorber, evaporator and condenser have been measured. The coefficient of performance of the system was calculated and then compared. The results showed that when the cycle driven by electricity, the coefficient of performance varied from 0.28-1.6 along the test time and the generator temperature changed from 66?C to 106?C. When thermal energy used to generate power, the coefficient of performance varied between 0.16 and 0.6 under the generator temperature of 98?C and 150?C. It was observed that the waste heat energy from engine exhaust can be used efficiently and can replace the conventional power source to drive the absorption refrigeration unit.


2021 ◽  
Vol 11 (5) ◽  
pp. 2442
Author(s):  
Adil Al-Falahi ◽  
Falah Alobaid ◽  
Bernd Epple

Absorption refrigeration cycle is considered a vital option for thermal cooling processes. Designing new systems is needed to meet the increasing communities’ demands of space cooling. This should be given more attention especially with the increasing conventional fossil fuel energy costs and CO2 emission. This work presents the thermo-economic analysis to compare between different solar absorption cooling system configurations. The proposed system combines a solar field, flashing tank and absorption chiller: two types of absorption cycle H2O-LiBr and NH3-H2O have been compared to each other by parabolic trough collectors and evacuated tube collectors under the same operating conditions. A case study of 200 TR total cooling load is also presented. Results reveal that parabolic trough collector combined with H2O-LiBr (PTC/H2O-LiBr) gives lower design aspects and minimum rates of hourly costs (5.2 $/h) followed by ETC/H2O-LiBr configuration (5.6 $/h). H2O-LiBr gives lower thermo-economic product cost (0.14 $/GJ) compared to the NH3-H2O (0.16 $/GJ). The absorption refrigeration cycle coefficient of performance ranged between 0.5 and 0.9.


Energies ◽  
2019 ◽  
Vol 12 (20) ◽  
pp. 3830 ◽  
Author(s):  
Villarroel-Schneider ◽  
Malmquist ◽  
Araoz ◽  
Martí-Herrero ◽  
Martin

Trigeneration or combined cooling, heat and power (CCHP) systems fueled by raw biogas can be an interesting alternative for supplying electricity and thermal services in remote rural areas where biogas can be produced without requiring sophisticated equipment. In this sense, this study considers a performance analysis of a novel small-scale CCHP system where a biogas-fired, 5 kWel externally fired microturbine (EFMT), an absorption refrigeration system (ARS) and heat exchangers are integrated for supplying electricity, refrigeration and hot water demanded by Bolivian small dairy farms. The CCHP solution presents two cases, current and nominal states, in which experimental and design data of the EFMT performance were considered, respectively. The primary energy/exergy rate was used as a performance indicator. The proposed cases show better energy performances than those of reference fossil fuel-based energy solutions (where energy services are produced separately) allowing savings in primary energy utilization of up to 31%. Furthermore, improvements in electric efficiency of the EFMT and coefficient of performance (COP) of the ARS, identified as key variables of the system, allow primary energy savings of up to 37%. However, to achieve these values in real conditions, more research and development of the technologies involved is required, especially for the EFMT.


2012 ◽  
Vol 16 (3) ◽  
pp. 131
Author(s):  
Didik Ariwibowo

Didik Ariwibowo, in this paper explain that energy audit activities conducted through several phases, namely: the initial audit, detailed audit, analysis of energy savings opportunities, and the proposed energy savings. Total energy consumed consists of electrical energy, fuel, and materials in this case is water. Electrical energy consumption data obtained from payment of electricity accounts for a year while consumption of fuel and water obtained from the payment of material procurement. From the calculation data, IKE hotels accounted for 420.867 kWh/m2.tahun, while the IKE standards for the hotel is 300 kWh/m2.tahun. Thus, IKE hotel included categorized wasteful in energy usage. The largest energy consumption on electric energy consumption. Largest electric energy consumption is on the air conditioning (AC-air conditioning) that is equal to 71.3%, and lighting and electrical equipment at 27.28%, and hot water supply system by 4.44%. Electrical energy consumption in AC looks very big. Ministry of Energy and Mineral Resources of the statutes, the profile of energy use by air conditioning at the hotel by 48.5%. With these considerations in the AC target for audit detail as the next phase of activity. The results of a detailed audit analysis to find an air conditioning system energy savings opportunities in pumping systems. Recommendations on these savings is the integration of automation on the pumping system and fan coil units (FCU). The principle of energy conservation in the pumping system is by installing variable speed drives (VSD) pump drive motor to adjust speed according to load on the FCU. Load variations FCU provide input on the VSD pumps to match. Adaptation is predicted pump can save electricity consumption up to 65.7%. Keywords: energy audit, IKE, AC


2006 ◽  
Vol 17 (3) ◽  
pp. 65-70 ◽  
Author(s):  
V Mittal ◽  
K S Kasana ◽  
N S Thakur

This paper presents modelling and simulation of a solar absorption cooling system. In this paper, the modelling of a solar-powered, single stage, absorption cooling system, using a flat plate collector and water–lithium bromide solution, is done. A computer program has been developed for the absorption system to simulate various cycle configurations with the help of various weather data for the village Bahal, District Bhiwani, Haryana, India. The effects of hot water inlet temperatures on the coefficient of performance (COP) and the surface area of the absorption cooling component are studied. The hot water inlet temperature is found to affect the surface area of some of the system components. Moreover the effect of the reference temperature which is the minimum allowable hot water inlet temperature on the fraction of total load met by non-purchased energy (FNP) and coefficient of performance (COP) is studied and it is found that high reference temperature increases the system COP and decreases the surface area of system components but lower reference temperature gives better results for FNP than high reference temperatures.


2019 ◽  
Vol 18 (2) ◽  
pp. 19
Author(s):  
L. S. Santana ◽  
J. Castro ◽  
L. M. Pereira

Vapor-compression refrigeration systems require a significant amount of electrical energy. Therefore, there is a need for finding efficient ways of operating this equipment, reducing their energy consumption. The use of heat exchangers between the suction line and the liquid line can produce a better performance of the thermodynamic cycle, as well as reduce it. The present work aims at an experimental analysis of the suction/liquid heat exchanger present in a freezer running with refrigerant fluid R-134a. Three different scenarios were used in order to evaluate the thermal performance of the refrigeration cycle. The first scenario was the conventional freezer set up to collect the required data for further comparison. Moreover, the second and third scenarios were introduced with a 20 cm and 40 cm suction/liquid heat exchanger, respectively, into the system. From the experiments, it was observed that the heat exchange does not significantly affect the coefficient of performance (COP) of the freezer. It was concluded from this work that the best scenario analyzed was the 20 cm suction/liquid heat exchanger where most of the thermodynamic properties were improved, one of them being the isentropic efficiency.


2012 ◽  
Vol 433-440 ◽  
pp. 1219-1225
Author(s):  
Jing Hong Ning ◽  
Sheng Chun Liu

This paper reports a combined space cooling, space heating, water heating and food refrigeration system (named CO2 combined system) in supermarket. This system using CO2 as the working fluid consists of a two-stage CO2 transcritical cycle used for food refrigeration, a single-stage CO2 transcritical cycle for space cooling in summer and space heating in winter. The waste heat emitted from the CO2 gas cooling in food refrigeration cycle and space cooling and space heating cycles is recovered by heat recover exchanger and is used to provide hot water for space heating and for general usage, such as the catering, the washing and the toilet facilities in the supermarket. So this CO2 combined system improves the coefficient of performance, decreases the energy consumption as well as reduces the heat pollution. Moreover, this CO2 combined system is compared with typical conventional supermarket technology, the results show that the energy consumption of CO2 combined system is reduced largely and energy efficiency is increased obviously. It can be concluded that the CO2 combined system has a good future for protecting environment and saving energy.


2016 ◽  
Vol 138 (5) ◽  
Author(s):  
Shahram Derakhshan ◽  
Alireza Yazdani

In critical situations such as floods and earthquakes, the relief forces require a refrigeration for pharmaceuticals and vaccines, which could operate without an electrical energy and the alternative energies, such as solar energy, engine exhaust gases heat, and wind energy. In this paper, a refrigeration cycle has been modeled as an adsorption refrigeration cycle with an activated carbon/methanol as adsorbent/adsorbate pair and two sources of energy—solar energy and engine exhaust gases heat. The solar cycle had a collector with area of 1 m2 and the exhaust gas cycle included a heat exchanger with 100 °C temperature difference between inlet and outlet gases. The temperature profile in adsorbent bed, evaporator, and condenser was obtained from modeling. Moreover, the pressure profile, overall heat transfer coefficient of collector and adsorbent bed, concentration, and the solar radiation were reported. Results represented the coefficient of performance (COP) of 0.55, 0.2, and 0.56 for complete system, solar adsorption refrigeration, and exhaust heat adsorption refrigeration, respectively. In addition, exhaust heat adsorption refrigeration has a value of 2.48 of specific cooling power (SCP). These results bring out a good performance of the proposed model in the climate of Iran.


2014 ◽  
Vol 1070-1072 ◽  
pp. 1679-1683
Author(s):  
Qin Ouyang ◽  
Guang Xiao Kou ◽  
Min Ouyang

According to the climate conditions of Hunan province and the design parameters related to air conditioning, the energy consumption and the related characteristics of the liquid desiccant evaporative cooling system (LDECS) are compared with primary return air conditioning system. The results show that energy consumption of LDECS can be decreased by 11.78% compared to the primary return air system. LDECS has a certain degree of energy saving potential in Hunan province, especially when waste heat is available.