scholarly journals Reinforcing Heat-cured Poly-methyl-methacrylate Resins using Fibers of Glass, Polyaramid, and Nylon: An in vitro Study

2016 ◽  
Vol 17 (11) ◽  
pp. 948-952 ◽  
Author(s):  
Gautam VS Kumar ◽  
Anupama Nigam ◽  
Ahmad Naeem ◽  
Abhishek Gaur ◽  
Kaushik Kumar Pandey ◽  
...  

ABSTRACT Introduction As civilization has progressed, there has been continued refinement of materials available for dental practice. The applications of resins have been extended to increased practical uses in numerous areas of prosthetic and restorative dentistry. Certain significant alterations in the technique of manipulation and nature of the dental product have influenced the range of application in dentistry. The present study was done to measure and compare the fracture strength of heat polymerized poly-methyl-methacrylate (PMMA) resin reinforced with fibers of glass, polyaramid, and nylon. Materials and methods The present study was conducted in vitro on 40 PMMA denture base resin specimens. Specimens were divided into four subgroups with ten specimens each and tested for transverse strength using universal testing machine. Results In group I, the transverse strength mean value was 67.82 MPa. In group II, the transverse strength mean value was 59.47 MPa. In group III, the transverse strength mean value was 66.87 MPa, while in group IV, the transverse strength mean value was 66.47 MPa. Conclusion Incorporation of 4% weight glass fibers in loose form significantly increased the transverse strength of denture base PMMA, while 4% of polyaramid fiber in random distribution significantly increased the transverse strength of denture base PMMA. How to cite this article Kumar VSG, Nigam A, Naeem A, Gaur A, Pandey KK, Deora A. Reinforcing Heat-cured Polymethyl- methacrylate Resins using Fibers of Glass, Polyaramid, and Nylon: An in vitro Study. J Contemp Dent Pract 2016; 17(11):948-952.

2012 ◽  
Vol 13 (3) ◽  
pp. 389-393
Author(s):  
Deepthi Kalahasti ◽  
Smitha Sharan ◽  
Harish Konde

ABSTRACT Aims To evaluate the effect of chemical disinfectant on the transverse strength of heat-polymerized acrylic resins subjected to mechanical and chemical polishing. Materials and methods A total of 256 rectangular specimens (65 × 10 × 3 mm) 128 per resin (Lucitone-199 and Acralyn-H) were fabricated. One side of each specimen was not polished and the other was either mechanically (n = 96) or chemically (n = 96) polished and immersed for 10, 30 and 60 minutes in 2% alkaline glutaraldehyde. Mechanically polished (n = 32) and chemically polished (n = 32) control specimens were immersed only in distilled water. The transverse strength (N/mm2) was tested for failure in a universal testing machine, at a crosshead speed of 5 mm/min. Data were statistically analyzed using 2-way ANOVA and Student t-test. Results chemical polishing resulted in significantly lower transverse strength values than mechanical polishing. Lucitone- 199 resin demonstrated the highest overall transverse strength for the materials tested. Heat-polymerized acrylic resins either mechanically or chemically polished, did not demonstrate significant changes in transverse strength during immersion in the disinfecting solution tested, regardless of time of immersion. Conclusion Lucitone-199 resin demonstrated the highest overall transverse strength for the materials tested and significantly stronger than Acralyn-H with either type of polishing following immersion in 2% alkaline glutaraldehyde. Clinical significance There is a concern that immersion in chemical solutions often used for cleansing and disinfection of prostheses may undermine the strength and structure of denture base resins. In this study it was observed that, the transverse strength of samples of Lucitone-199 was higher than that of the samples of Acralyn-H. The chances of fracture of the denture made of Lucitone-199 are less than that of dentures made of Acralyn-H. The chemically polished dentures may be more prone to fracture than mechanically polished dentures. How to cite this article Sharan S, Kavitha HR, Konde H, Kalahasti D. Effect of Chemical Disinfectant on the Transverse Strength of Heat-polymerized Acrylic Resins Subjected to Mechanical and Chemical Polishing: An in vitro Study. J Contemp Dent Pract 2012;13(3):389-393.


2019 ◽  
Vol 1 (1) ◽  
pp. 35
Author(s):  
Pramudya Aditama ◽  
Erwan Sugiatno ◽  
Sabdayana Sabdayana

Acrylic resin is the most commonly used denture base material. However, it has a shortage of being easily broken. One way to resolve this problem is by adding polyethylene (PE) or glass fibers. The purpose of this research is to compare the transversal strength of PE and glass fibers from denture plate acrylic resin repair material. The experiment involved 32 plates of heat cure acrylic with the dimensions of 65 mm x 10 mm x 2.5 mm. The speciments were prepared to create a 3 mm gap and 45° bevel. Subjects were divided into 2 groups, each group containing 16 plates. Group I was reinforced with PE fiber and Group II was reinforced with glass fiber. All plates were soaked in distillation water for one day at 37 °C. Plates were tested for transverse strength with universal testing machine and all data were analyzed with independent t-tes at 95% confidence level. Macro photo analysis was used to observed the bond failure on fiber and resin. The mean of transverse strength (MPa) denture plate acrylic resin repair material reinforced with PE fiber was (67.38 ± 4.31) MPa, while glass fiber was (93.61 ± 6.14) MPa. Independent t-tes showed that type of fiber had a significant effect (p<0.05). Thus, it is possible to conclude that addition of glass fibers in denture plate acrylic resin repair material increased the transverse strength and made it stronger than those added with PE fibers.


2017 ◽  
Vol 11 (01) ◽  
pp. 058-063 ◽  
Author(s):  
Vini Rajeev ◽  
Rajeev Arunachalam ◽  
Sanjna Nayar ◽  
P. R. Arunima ◽  
Sivadas Ganapathy ◽  
...  

ABSTRACT Objective: This in vitro study was designed to assess shear bond strength (SBS) of ormocer flowable (OF) resin as a luting agent, ormocer as an indirect veneer material with portrayal of modes of failures using scanning electron microscope (SEM). Materials and Methods: Sixty maxillary central incisors were divided into Group I, II, and III with 20 samples each based on luting cement used. They were OF, self-adhesive (SA) cement, and total etch (TE) cement. These groups were subdivided into “a” and “b” of ten each based on the type of veneering materials used. Veneer discs were fabricated using Ormocer restorative (O) and pressable ceramic (C). Specimens were thermocycled and loaded under universal testing machine for SBS. The statistical analysis was done using one-way ANOVA post hoc Tukey honest significant difference method. Results: A significant difference was observed between the Groups I and II (P < 0.05). The highest mean bond strength when using ormocer veneer was obtained with the Group Ia (19.11 ± 1.92 Mpa) and lowest by Group IIa (8.1 ± 1.04 Mpa), whereas the highest mean bond strength while using ceramic veneer was of similar range for Group Ib (18.04 ± 4.08 Mpa) and Group IIIb (18.07 ± 1.40 Mpa). SEM analysis revealed OF and TE presented mixed type of failure when compared with SA where failure mode was totally adhesive. Conclusion: OF was found equally efficient like TE. Bond strength of ormocer as a veneer was not inferior to ceramic making it one of the promising additions in the field of dentistry.


2003 ◽  
Vol 27 (1) ◽  
pp. 35-39 ◽  
Author(s):  
Silvia Pithan ◽  
Ricardo de Sousa Vieira ◽  
Marcelo Carvalho Chain

The aim of this study was to measure in vitro; the tensile bond strength of three intracanal posts used in anterior primary teeth. A total of 45 single rooted primary anterior teeth were selected for the study and the crowns sectioned leaving 1mm above the cement-enamel junction. The roots were then assigned to three groups according the type of retention used. All roots were endodonticaly treated, a 4-mm of the canal was cleansed and a base of glass ionomer cement was put at the bottom of the prepared canal. The roots were then prepared to receive intracanal posts using a # 4137 diamond bur (KG Sorensen) used in a depth of 3-mm of the length of the canal. All the prepared roots were acid etched with a 37% phosphoric acid gel for 15 seconds, rinsed, dried and the dentin adhesive Single Bond (3M) was applied. Group I received intracanal posts and cores made of composite resin (Filtek Z 250, 3M). Group II intracanal posts were made from a 0.6mm orthodontic wire bent as a Greek letter type (gamma), fixed with the Z 250 composite resin and cores were built with the same composite. Finally Group III received intracanal retention made of a fiber glass post (Fibrekor Post, Generic/Pentron) with 1.25mm diameter, fixed with Z 250 and cores were made like the other groups. The samples were submitted to tension in a universal- testing machine (Instron, model 4444). Statistical analysis (ANOVA) reveled that there were no statistically significant differences between the groups. On the basis of the results of this in vitro study it was concluded that the type of intracanal post did not interfere with the tensile strength and the most frequent type of failure was of adhesive type, corresponding to 74% of the sample.


2021 ◽  
Vol 24 (4) ◽  
Author(s):  
Ayman Sabbah ◽  
Mostafa Kamel

Objective: This study aimed to assess the fracture resistance of primary molars restored with endocrowns compared to prefabricated zirconia crowns. Methods: Twelve sound, defect-free primary second molars were selected and divided into two groups: group I included 6 molars restored with zirconia crowns, while group II included 6 teeth restored with endocrowns. For both groups access cavity was prepared for the teeth to open pulp chamber. Fracture resistance of both groups was tested using a universal testing machine. Results: Zirconia crown showed statistically significantly higher mean fracture resistance than Endocrown (P-value = 0.001, Effect size = 2.72). Conclusion: Pulpotomized primary molars restored with Zirconia crowns showed significantly higher mean fracture resistance compared to primary molars restored with endocrowns, meanwhile both restorations have shown higher mean fracture resistance than the maximum biting force in children. Keywords  Composite resins; Endocrown; Fracture strength; Zirconia crowns.


2015 ◽  
Vol 1 (1) ◽  
pp. 102
Author(s):  
Pramudya Aditama ◽  
Siti Sunarintyas ◽  
Widjijono Widjijono

Resin akrilik merupakan bahan yang sering digunakan dalam pembuatan basis gigi tiruan. Kelemahan resin akrilik adalah mudah patah. Salah satu cara untuk mengatasi masalah tersebut adalah dengan menambahkan polyethylene (PE) atau glass fiber. Tujuan dari penelitian ini untuk mengetahui pengaruh jenis dan volumetrik fiber terhadap kekuatan transversal reparasi plat resin akrilik. Penelitian ini menggunakan dua puluh lima plat resin akrilik kuring panas berukuran 65 x 10 x 2,5 mm. Subjek dipreparasi untuk membuat jarak 3 mm dan sudut bevel 45o. Subjek dibagi menjadi 5 kelompok, masingmasing kelompok terdiri dari 5 subjek. Kelompok 1 (kontrol) tanpa penambahan fiber, kelompok II dengan penambahan 3,7% v/v PE fiber, kelompok III dengan penambahan 7,4% v/v PE fiber, kelompok IV dengan penambahan 3,7% v/v E-glass fiber, dan kelompok V dengan penambahan 7,4% v/v E-glass fiber. Seluruh plat direndam dalam air destilasi selama satu hari pada suhu 37oC. Pengujian kekuatan transversal plat resin akrilik dengan menggunakan Universal Testing Machine dan data yang didapat dianalisis menggunakan ANAVA dua jalur dengan tingkat kepercayaan 95%. Rerata kekuatan transversal (MPa) reparasi plat resin akrilik yang diperkuat fiber: 3,7% v/v PE fiber (67,77±3,34); 7,4% v/v PE fiber (80,37±8,42); 3,7% v/v E-glass fiber (96,72±5,43); 7,4% v/v E-glass fiber (109,44±4,98); sedangkan reparasi plat resin yang tidak diperkuat fiber menghasilkan kekuatan transversal 56,27±4,7 MPa. Hasil analisis menggunakanANAVA dua jalur menunjukkan variabel jenis dan volumetrik fiber memberikan pengaruh signifikan (p<0,05), sedangkan interaksi antara jenis dan volumetrik fiber tidak berpengaruh signifikan (p>0,05). Uji post hoc Tukey menunjukkan perbedaan signifikan (p<0,05) untuk seluruh kelompok perlakuan. Penambahan E-glass fiber dalam reparasi plat resinakrilik mampu meningkatkan kekuatan transversal lebih tinggi dibandingkan dengan menggunakan PE fiber. Peningkatan volumetrik fiber dapat meningkatkan kekuatan transversal reparasi plat resin akrilik. Effect Of Type And Volumetric Fiber On Transverse Strength Of Acrylic Resin Plate Repair. Acrylic resin is the most common denture base material. A disadvantage of acrylic resin is that it is easily fractured. One way to resolve this problem is by adding polyethylene (PE) or glass fibers. The purpose of this research is to find out about the effect of type and volumetric fiber on transverse strength of acrylic resin plate repaired. The experiment involved twenty five plates of heat cured acrylic with the dimensions of 65 x 10 x 2.5 mm. The speciments were prepared to create a 3 mm gap and 45° bevel. The subjects were divided into 5 groups; each group consisted of 5. Group I (control) was without fiber reinforcement, group II reinforced with 3.7% v/v PE fiber, group III reinforced with 7.4% v/v PE fiber, group IV reinforced with 3.7% v/v E-glass fiber, and group V reinforced with 7.4% v/v E-glass fiber. All plates were soaked in distilled water for one day at 37° C temperature. The plates were tested for transverse strength with Universal Testing Machine and all data obtained were analyzed with two way ANOVA at 95% confidence level. The mean of transverse strength (MPa) of the acrylic resin plate repair reinforced with fiber: 3.7% v/v PE fiber was (67.77±3.34); 7.4% v/v PE fiber (80.37±8.42); 3.7% v/v E-glass fiber (96.72±5.43); 7.4% v/v E-glass fiber (109.44±4.98); while the transverse strength of the acrylic resin plate with no fiber reinforced was 56.27±4.7 MPa. Two way ANOVA analysis shows that type and volumetric fiber had significant effect (p<0.05), while the interaction between type and volumetric fiber had no significant effect (p>0.05). Tukey post hoc test shows significant difference (p<0.05) for all groups. The addition of E-glass fibers in the acrylic resin plate repaired increased the transverse strength higher than that with PE fibers. The increase in volumetric fibers might improve the transverse strength of the acrylic resin plate repaired.


2017 ◽  
Vol 1 ◽  
Author(s):  
Annisa Mayang Rusdi ◽  
Lasminda Syafiar ◽  
Astrid Yudhit

<p class="AbstractContent"><strong>Objective:</strong> The purpose of this study was to evaluate transverse strength of heat cured acrylic resin after immersed in 0,2% chlorhexidine gluconate mouthwash for 15, 30, 45, and 60 minutes.</p><p class="AbstractContent"><strong>Methods:</strong> This was an experimental laboratory study with posttest only group design. The samples were heat cured acrylic resin plate with size 65mm x 10mm x 2,5mm. Polymerization of the heat cured acrylic was done by water bath (74 °C for 2hrs followed by 100 °C for 1hr). Totally 30 samples were prepared and divided into 5 groups (n=6) which are group I as control, and others were immersed in 0, 2% chlorhexidine gluconate, group II (15 minutes), group III (30 minutes), group IV (45 minutes) and group V (60 minutes) respectively. The transverse strength was test using Torsee’s Universal Testing machine, Japan with crosshead 1/10 mm/seconds. The data was statistically analyzed using one way ANOVA (p≤0,005).</p><p class="AbstractContent"><strong>Results:</strong> Means and Standard deviation of Transverse strength were 92.382±11.786 N/mm2, 92.186±13.349 N/mm2,92.578±12.492 N/mm2, 92.382±13.939 N/mm2, and 91.989±12.285 N/mm2 for group I, II, III, IV, and V respectively. Statistic analyzed showed no significant difference among groups with p value= 1,000 (p &lt; 0, 05).</p><p class="AbstractContent"><strong>Conclusion:</strong> The immersion in 0, 2% chlorhexidine gluconate mouthwash at different period does not changed transverse strength of heat cured acrylic resin.</p>