scholarly journals Transverse Strength of Heat Cured Acrylic Resin After Immersed in 0, 2% Chlorhexidine Gluconate Mouthwash (In Vitro)

2017 ◽  
Vol 1 ◽  
Author(s):  
Annisa Mayang Rusdi ◽  
Lasminda Syafiar ◽  
Astrid Yudhit

<p class="AbstractContent"><strong>Objective:</strong> The purpose of this study was to evaluate transverse strength of heat cured acrylic resin after immersed in 0,2% chlorhexidine gluconate mouthwash for 15, 30, 45, and 60 minutes.</p><p class="AbstractContent"><strong>Methods:</strong> This was an experimental laboratory study with posttest only group design. The samples were heat cured acrylic resin plate with size 65mm x 10mm x 2,5mm. Polymerization of the heat cured acrylic was done by water bath (74 °C for 2hrs followed by 100 °C for 1hr). Totally 30 samples were prepared and divided into 5 groups (n=6) which are group I as control, and others were immersed in 0, 2% chlorhexidine gluconate, group II (15 minutes), group III (30 minutes), group IV (45 minutes) and group V (60 minutes) respectively. The transverse strength was test using Torsee’s Universal Testing machine, Japan with crosshead 1/10 mm/seconds. The data was statistically analyzed using one way ANOVA (p≤0,005).</p><p class="AbstractContent"><strong>Results:</strong> Means and Standard deviation of Transverse strength were 92.382±11.786 N/mm2, 92.186±13.349 N/mm2,92.578±12.492 N/mm2, 92.382±13.939 N/mm2, and 91.989±12.285 N/mm2 for group I, II, III, IV, and V respectively. Statistic analyzed showed no significant difference among groups with p value= 1,000 (p &lt; 0, 05).</p><p class="AbstractContent"><strong>Conclusion:</strong> The immersion in 0, 2% chlorhexidine gluconate mouthwash at different period does not changed transverse strength of heat cured acrylic resin.</p>

2015 ◽  
Vol 1 (1) ◽  
pp. 102
Author(s):  
Pramudya Aditama ◽  
Siti Sunarintyas ◽  
Widjijono Widjijono

Resin akrilik merupakan bahan yang sering digunakan dalam pembuatan basis gigi tiruan. Kelemahan resin akrilik adalah mudah patah. Salah satu cara untuk mengatasi masalah tersebut adalah dengan menambahkan polyethylene (PE) atau glass fiber. Tujuan dari penelitian ini untuk mengetahui pengaruh jenis dan volumetrik fiber terhadap kekuatan transversal reparasi plat resin akrilik. Penelitian ini menggunakan dua puluh lima plat resin akrilik kuring panas berukuran 65 x 10 x 2,5 mm. Subjek dipreparasi untuk membuat jarak 3 mm dan sudut bevel 45o. Subjek dibagi menjadi 5 kelompok, masingmasing kelompok terdiri dari 5 subjek. Kelompok 1 (kontrol) tanpa penambahan fiber, kelompok II dengan penambahan 3,7% v/v PE fiber, kelompok III dengan penambahan 7,4% v/v PE fiber, kelompok IV dengan penambahan 3,7% v/v E-glass fiber, dan kelompok V dengan penambahan 7,4% v/v E-glass fiber. Seluruh plat direndam dalam air destilasi selama satu hari pada suhu 37oC. Pengujian kekuatan transversal plat resin akrilik dengan menggunakan Universal Testing Machine dan data yang didapat dianalisis menggunakan ANAVA dua jalur dengan tingkat kepercayaan 95%. Rerata kekuatan transversal (MPa) reparasi plat resin akrilik yang diperkuat fiber: 3,7% v/v PE fiber (67,77±3,34); 7,4% v/v PE fiber (80,37±8,42); 3,7% v/v E-glass fiber (96,72±5,43); 7,4% v/v E-glass fiber (109,44±4,98); sedangkan reparasi plat resin yang tidak diperkuat fiber menghasilkan kekuatan transversal 56,27±4,7 MPa. Hasil analisis menggunakanANAVA dua jalur menunjukkan variabel jenis dan volumetrik fiber memberikan pengaruh signifikan (p<0,05), sedangkan interaksi antara jenis dan volumetrik fiber tidak berpengaruh signifikan (p>0,05). Uji post hoc Tukey menunjukkan perbedaan signifikan (p<0,05) untuk seluruh kelompok perlakuan. Penambahan E-glass fiber dalam reparasi plat resinakrilik mampu meningkatkan kekuatan transversal lebih tinggi dibandingkan dengan menggunakan PE fiber. Peningkatan volumetrik fiber dapat meningkatkan kekuatan transversal reparasi plat resin akrilik. Effect Of Type And Volumetric Fiber On Transverse Strength Of Acrylic Resin Plate Repair. Acrylic resin is the most common denture base material. A disadvantage of acrylic resin is that it is easily fractured. One way to resolve this problem is by adding polyethylene (PE) or glass fibers. The purpose of this research is to find out about the effect of type and volumetric fiber on transverse strength of acrylic resin plate repaired. The experiment involved twenty five plates of heat cured acrylic with the dimensions of 65 x 10 x 2.5 mm. The speciments were prepared to create a 3 mm gap and 45° bevel. The subjects were divided into 5 groups; each group consisted of 5. Group I (control) was without fiber reinforcement, group II reinforced with 3.7% v/v PE fiber, group III reinforced with 7.4% v/v PE fiber, group IV reinforced with 3.7% v/v E-glass fiber, and group V reinforced with 7.4% v/v E-glass fiber. All plates were soaked in distilled water for one day at 37° C temperature. The plates were tested for transverse strength with Universal Testing Machine and all data obtained were analyzed with two way ANOVA at 95% confidence level. The mean of transverse strength (MPa) of the acrylic resin plate repair reinforced with fiber: 3.7% v/v PE fiber was (67.77±3.34); 7.4% v/v PE fiber (80.37±8.42); 3.7% v/v E-glass fiber (96.72±5.43); 7.4% v/v E-glass fiber (109.44±4.98); while the transverse strength of the acrylic resin plate with no fiber reinforced was 56.27±4.7 MPa. Two way ANOVA analysis shows that type and volumetric fiber had significant effect (p<0.05), while the interaction between type and volumetric fiber had no significant effect (p>0.05). Tukey post hoc test shows significant difference (p<0.05) for all groups. The addition of E-glass fibers in the acrylic resin plate repaired increased the transverse strength higher than that with PE fibers. The increase in volumetric fibers might improve the transverse strength of the acrylic resin plate repaired.


2017 ◽  
Vol 1 (1) ◽  
pp. 20-25
Author(s):  
Pooja Kabra

ABSTRACT Aim The purpose of this study was to evaluate the fracture strength of roots instrumented with the self-adjusting file (SAF; ReDent-Nova, Ra'anana, Israel) and the Reciproc reciprocating file and that were and were not obturated using the warm vertical lateral compaction technique. Materials and methods In total, 75 mandibular premolar teeth were sectioned at or below the cementoenamel junction to obtain roots 13 mm in length. The roots were balanced with respect to buccolingual and mesiodistal diameters and weight. They were distributed into four experimental groups and one control group (n = 15): No instrumentation (group I), instrumentation with SAF files but no obturation (group II), instrumentation with SAF files and obturated with warm vertical lateral compaction (group III), instrumentation with Reciproc File but no obturation (group IV), and instrumentation with Reciproc File and obturated with warm vertical lateral compaction (group V). AH Plus sealer (Dentsply DeTrey, Konstanz, Germany) was used along with gutta-percha points. One week later, a vertical load was applied to the specimen's canal until fracture occurred. Data were statistically analyzed using one-way analysis of variance (p = 0.05). Results The mean fracture load was 312.83 N for group I, 297.35 N for group II, 359.15 N for group III, 231.51 N for group IV, and 275.81 N for group V. Conclusion The fracture resistances exhibited a statistically significant difference between all the groups. Teeth instrumented by SAF exhibited a better fracture resistance. How to cite this article Tyagi S, Choudhary E, Kabra P, Chauhan R. An in vitro comparative Evaluation of Fracture Strength of Roots Instrumentated with Self-adjusting File and Reciproc Reciprocating File, with and without Obturation. Int J Clin Dent Res 2017;1(1):20-25.


2015 ◽  
Vol 09 (02) ◽  
pp. 224-227 ◽  
Author(s):  
Shenbagakuttalam Anand ◽  
Ambrose Vedamanickam Rajesh Ebenezar ◽  
Nirupa Anand ◽  
Kothandaraman Rajkumar ◽  
Sekar Mahalaxmi ◽  
...  

ABSTRACT Objectives: To comparatively assess the micro shear bond strength (MSBS) of dentin bonded surface pre-treated zirconia ceramics. Materials and Methods: Zirconia blocks were sectioned into 50 cubical blocks. The blocks were further categorized into five groups (n = 10 each). Group I: No treatment was performed on zirconia samples; Group II: The zirconia samples were sand-blasted; Group III: Group II + etched with 9.8% of hydrofluoric (HF) acid for 60 s; Group IV: The sandblasted zirconia samples were selectively infiltrated with low fusing porcelain; and Group V: Group IV + etched using 9.8% HF acid gel. The zirconia specimens were then bonded to dentin samples, and the samples were tested for MSBS evaluation using universal testing machine. Results: The MSBS of all the four experimental groups shows greater value than group I. Among the experimental groups, group V and group IV do not show any statistical significant difference, whereas the mean MSBS of groups IV and V were statistically greater than group III and group II. However, groups I, II, and III do not show any statistical significant difference in mean MSBS values between them. Conclusion: Selective infiltration etching of zirconia ceramics provides the highest bond strength with resin cement.


2021 ◽  
Vol 10 (40) ◽  
pp. 33-37
Author(s):  
Joyce de Figueiredo Meira Barbosa ◽  
Lara Pepita de Souza Oliveira ◽  
Marcelo Nascimento Bruce ◽  
Jonas Alves Oliveira ◽  
Ligia Regina Mota Vasconcelos ◽  
...  

Acrylic denture teeth may suffer fracture or wear requiring the need for repair. This study aimed to evaluate the shear bond strength between acrylic resin artificial teeth restored with composite resin (with two different surface treatments) and acrylic resin (AR), simulating repair with these materials. Thirty artificial incisors were included by the palatal side in a circular microwave-polymerized AR base and polished on their buccal side with 120 and 320 grit sandpaper in a metallographic polisher and, then, divided into three groups: (I) restoration with self-cured AR; (II) conventional restoration with Z-100 composite resin with application of acid etching and Single Bond-3M adhesive; and (III) restoration with Z-100 composite resin with submersion for 30 seconds in acetone and application of Single Bond-3M adhesive. Shear bond strength tests were performed in a Universal Testing Machine (Instron). The results were submitted to ANOVA and Tukey (p<0.05) tests, in which Group I (33.26MPa ±10.76) and Group III (22.24MPa ±13.13) showed no statistically significant difference, but both were superior to Group II (10.31MPa ±5.62), which showed a lower value of shear bond strength. It can be concluded that composite resin restoration with acetone pretreatment can be a viable alternative for repair.


2009 ◽  
Vol 20 (3) ◽  
pp. 211-214 ◽  
Author(s):  
Michele Regina Nadalin ◽  
Danyel Elias da Cruz Perez ◽  
Luiz Pascoal Vansan ◽  
Cristina Paschoala ◽  
Manoel Damião Souza-Neto ◽  
...  

This study evaluated in vitro the capacity of debris removal from the apical third of flattened root canals, using different final irrigation protocols. Thirty human mandibular central incisors with a mesiodistal flattened root were prepared using rotary instrumentation by Endo-Flare 25.12 and Hero 642 30.06, 35.02, 40.02 files, irrigated with 2 mL of 1% NaOCl after each file. The specimens were randomly distributed into 5 groups according to the final irrigation of root canals: Group I: 10 mL of distilled water (control), Group II: 10 mL of 1% NaOCl for 8 min, Group III: 2 mL of 1% NaOCl for 2 min (repeated 4 times), Group IV: 10 mL of 2.5% NaOCl for 8 min, and Group V: 10 mL of 2.5% NaOCl for 2 min (repeated 4 times). The apical thirds of the specimens were subjected to histological processing and 6-μm cross-sections were obtained and stained with hematoxylin-eosin. The specimens were examined under optical microscopy at ×40 magnification and the images were subjected to morphometric analysis using the Scion image-analysis software. The total area of root canal and the area with debris were measured in square millimeters. Analysis of variance showed no statistically significant difference (p>0.05) among the groups GI (2.39 ± 3.59), GII (2.91 ± 2.21), GIII (0.73 ± 1.36), GIV (0.95 ± 0.84) and GV (0.51 ± 0.22). In conclusion, the final irrigation protocols evaluated in this study using the Luer syringe presented similar performance in the removal of debris from the apical third of flattened root canals.


2013 ◽  
Vol 18 (2) ◽  
pp. 95-100 ◽  
Author(s):  
Marcus Vinicius Neiva Nunes do Rego ◽  
Roanselli Marllon Lima dos Santos ◽  
Leanne Matias Portela Leal ◽  
Carlos Gustavo Silva Braga

OBJECTIVE: The purpose of this study was to evaluate, in vitro, the bond strength of brackets bonded to premolars previously subjected to bleaching with a 35% hydrogen peroxide. METHODS: Twenty one healthy premolars were selected and randomly divided into three groups (n = 7). Group I (G1) included teeth that were not submitted to bleaching. The enamel surfaces of Groups II (G2) and III (G3) were submitted to a bleaching process with 35% hydrogen peroxide (Whiteness HP Maxx). On Group II (G2), after bleaching, the teeth were stored for 24 hours in distilled water at 98.6 ºF, and then, premolar metallic brackets were bonded using Transbond XT (3M) resin. Group III (G3) was submitted to the same procedure seven days after bleaching. After bonding, all teeth were stored in distilled water at 98.6 ºF for 24 hours. All groups were submitted to a traction test using an EMIC DL2000 universal testing machine at a speed of 0.5 mm/min. RESULTS AND CONCLUSION: The bracket resistance to debonding was compared between the groups by the Kruskal-Wallis nonparametric test (p < 0.05) and it was verified that the bleaching agent significantly reduced bracket adhesion when bonded 24 hours after bleaching. However, seven days after bleaching, there was no significant difference on the resistance to debonding among groups G1 (19,52 kgf) and G3 (18,44 kgf), meaning that it is necessary to wait longer after bleaching to bond brackets.


2020 ◽  
Vol 8 (2) ◽  
pp. 38
Author(s):  
Nisha Acharya ◽  
Md Riasat Hasan ◽  
Dashrath Kafle ◽  
Anil Chakradhar ◽  
Takashi Saito

Objective: Endodontic treatment should be both conservative and effective. Endodontic instruments with a greater taper are used for coronal flaring, for proper debridement with efficient irrigation. However, increased taper of an instrument can remove a larger amount of pericervical dentin, compromising the strength of the tooth. The aim of this study was to determine the effect of hand files, ProTaper Universal, ProTaper Next, and V Taper rotary instrument systems on the fracture resistance of teeth. Materials and Methods: In total, 60 extracted human maxillary first premolars were divided into four groups—Group I (Hand Files; HF), Group II (ProTaper Universal; PT), group III (ProTaper Next; PTN) and Group IV (V Taper; VT) (N = 15). Each group was instrumented with the respective instrument system, irrigated, obturated, restored, and mounted in cold cure acrylic. A universal load-testing machine (Shimadzu, Japan) was used to apply a vertical compressive load. The maximum force was recorded in Newton. Analysis of variance (ANOVA) and Independent t-tests were applied to compare the maximum mean force required to fracture the tooth. Results: There was a statistically significant difference in fracture resistance between Group I (HF) and Group II (PT) and between Group II (PT) and Group IV (VT) (p < 0.001). Similarly, a significant difference was observed between Group II (PT) and Group III (PTN) (p < 0.01). Furthermore, a significant difference was observed between Group I (HF) and Group III (PTN), and between Group III (PTN) and Group IV (VT) (p < 0.05), too. However, there was no statistically significant difference between Group I (HF) and group IV (VT) (p > 0.05). Conclusion: Rotary files with more taper seem to remove more pericervical dentin than traditional manual and rotary files with less taper, thus altering the strength of the tooth.


2017 ◽  
Vol 2 (1) ◽  
pp. 40
Author(s):  
Pramudya Aditama ◽  
Erwan Sugiatno ◽  
Muhamad Rifqi Tri Nuryanto

The effect of e-glass fiber volumetric on transverse strength of an acrylic resin denture plate repair. Acrylic resin is the most commonly material for the denture base. A disadvantage of acrylic resin is that it is easily to be cracked. One of the ways to resolve this problem is by adding the E-glass fibers. The purpose of this research was to find out the effect of volumetric E-glass fiber on transverse strength of an acrylic resin denture plate repair. The experiment involved thirty plates of heat cured acrylic with the dimensions of 65 × 10 × 2.5 mm. The specimens were prepared to create a 3-mm gap and 45° bevel. Subjects were divided in to 3 groups, each of which contained 10. Group I (control) was with no fiber reinforcement, group II was reinforced with 3.7vol % E-glass fiber, and group III was reinforced with 7.4 volume % E-glass fiber. All plates were soaked in distillation water for one day at 37 °C. Plates were tested for transverse strength with Universal Testing Machine and all data obtained was analyzed with one way anova at 95% confidence level (α= 0.05). The significant difference was found between the transversal force of acrylic resin plat enforced with fiber and other group without being reinforced with fibers (p<0.05). Group reinforced with 7.4 vol % E-glass fibers showed a significant difference (higher) than the group reinforced with 3.7 volume % fibers. The addition of E-glass fibers in an acrylic resin plate repair material increased the transverse strength. The increase in volumetric fibers might improve the transverse strength of an acrylic resin plate repair material.ABSTRAKResin akrilik merupakan bahan yang sering digunakan dalam pembuatan basis gigi tiruan. Kekurangan dari bahan resin akrilik adalah mudah patah. Salah satu cara yang dapat digunakan untuk mengatasi masalah tersebut adalah dengan menambahkan E-glass fiber. Tujuan untuk mengetahui pengaruh volumetrik E-glass fiber terhadap kekuatan transversal reparasi plat gigi tiruan resin akrilik. Penelitian ini menggunakan tiga puluh plat resin akrilik kuring panas dengan ukuran 65 × 10 × 2,5 mm. Spesimen dipreparasi untuk membentuk jarak 3 mm dan sudut bevel 45°. Subjek kemudian dibagi menjadi 3 kelompok, setiap kelompok terdiri dari 10 plat. Kelompok I (kontrol) tanpa diberikan penguat fiber, kelompok II diperkuat dengan 3,7 vol % E-glass  ber, dan kelompok III diperkuat dengan 7,4 vol % E-glass fiber. Seluruh plat kemudian direndam dalam air destilasi selama satu hari pada suhu 37 °C. Plat resin akrilik kemudian diuji menggunakan Universal Testing Machine untuk mengetahui kekuatan transversal dan data yang didapatkan dianalisis menggunakan Anova satu jalur dengan tingkat kepercayaan 95% (α=0,05). Hasil menunjukkan terdapat perbedaan signifikan antara kekuatan transversal plat resin akrilik yang diperkuat dengan fiber dengan kelompok tanpa diperkuat fiber (p < 0,05). Kelompok yang diperkuat dengan 7,4 vol % E-glass fiber menunjukkan perbedaan signi kan (lebih tinggi) dibandingkan kelompok yang diperkuat dengan 3,7 vol % fiber. Kesimpulan bahwa peningkatan volume dari E-glass fiber dapat meningkatkan kekuatan transversal reparasi plat gigi tiruan resin akrilik.


2015 ◽  
Vol 16 (5) ◽  
pp. 372-375 ◽  
Author(s):  
Adelson Mota de Aguiar ◽  
Arilton Mota de Aguiar ◽  
Célia Regina Maio Pinzan-Vercelino ◽  
Fausto Silva Bramante

ABSTRACT Aim This study sought to compare the fracture resistance of three trademarked orthodontic mini-implants in the transmucosal profile region. Thirty-six mini-implants of three different brands, separated into groups I, II and III, were tested. Each group consisted of 12 mini-implants of 6 mm in length. The mean diameter and length of the transmucosal profile of the mini-implants were 1.90 and 2.0 mm in group I, 1.77 and 1.0 mm in group II and 1.50 and 1.0 mm in group III, respectively. The tests were performed on a universal testing machine in compression mode, with a 2,000 kgf load, a speed of 4.0 mm per minute and a chisel-shaped active tip, which acted crosssectionally on the transmucosal profile. Single-criterion analysis of variance was used to compare the three brands. A significance level of 5% and test power of 80% were adopted. The mean fracture resistance achieved by the mini-implants was 172.03 ± 25.59 N for group I, 162.35 ± 30.81 N for group II and 139.69 ± 42.99 N for group III. There was no statistically significant difference in mean fracture resistance among the tested mini-implant brands. Conclusion The transmucosal profile diameter does not seem to be a deciding factor in the choice of mini-implants to minimize the risk of fractures. Clinical significance Although being an in vitro study it is possible to believe that this new brand has a very satisfactory resistance to fracture and enables its use with great efficiency. How to cite this article de Aguiar AM, Bramante FS, de Aguiar AM, Pinzan-Vercelino CRM. Evaluation of Fracture Resistance of Orthodontic Mini-implants in the Transmucosal Profile Region. J Contemp Dent Pract 2015;16(5):372-375.


2005 ◽  
Vol 13 (2) ◽  
pp. 141-146 ◽  
Author(s):  
Murilo Pereira de Melo ◽  
Accácio Lins do Valle ◽  
Jefferson Ricardo Pereira ◽  
Wellington Cardoso Bonachela ◽  
Luiz Fernando Pegoraro ◽  
...  

OBJECTIVES: The aim of this study was to evaluate the influence of remaining coronal tooth structure on endodontically treated teeth restored with prefabricated posts and two different composites for core build-up: dual-cured resin (Enforce Core) and light-cured resin (Z-250). METHODS: Fourty freshly extracted canines were endodontically treated and divided into four groups: Group I - teeth with 3mm remaining coronal structure, restored with Enforce Core; Group II - teeth with 3mm remaining coronal structure, restored with Z-250; Group III - teeth with no remaining coronal structure, restored with Enforce; Group IV - teeth with no remaining coronal structure, restored with Z-250. After restoration, the teeth were embedded in acrylic resin and the fracture resistance was measured on a universal testing machine at 45 degrees to the long axis of the tooth until failure. RESULTS: Data were analyzed by two-way analysis of variance, which showed significant differences between groups (p=0.00). The Tukey test did not show significant differences between specimens with and without remaining coronal structure. Conversely, significant difference was observed between groups with different core build-up. The highest values of fracture resistance were found in the group restored with light-cured resin. SIGNIFICANCE: The remaining coronal tooth structure did not influence the resistance of endodontically treated teeth; however, the change of core build-up was able to modify this resistence.


Sign in / Sign up

Export Citation Format

Share Document