A Study of Scaling and Corrosion In Condenser Tubes Exposed to River Water

CORROSION ◽  
1961 ◽  
Vol 17 (12) ◽  
pp. 579t-588t ◽  
Author(s):  
R. A. McALLISTER ◽  
DONALD H. EASTHAM ◽  
NEIL A. DOUGHARTY ◽  
MITCHELL HOLLIER

Abstract The series of tests reported give quantitative data on the rates of fouling and corrosion in 17 to 20 ft condenser tubes under simulated operating conditions using Neches River water as the cooling medium. Alloys tested were: 90–10 Cupro-nickel, aluminum-brass, Alclad aluminum, admiralty, three stainless steels, and alloy 77. Heat-transfer coefficients and Fanning friction factors were measured three times daily for 3 to 4 months. Several mechanisms of the fouling rate function were employed to compare the results. It appears that the heat-transfer coefficient is essentially linear with time and that the rate of fouling, initially at least, is not a function of velocity, but is a function of chloride-ion concentration (or hardness). The effects of weekly caustic addition, continuous cathodic protection, and river-water velocity were examined. Other river-water variables measured included pH, chloride-ion content, and hardness. The effects of these variables are discussed qualitatively. 3.3.2, 4.6.7, 7.4.2

1992 ◽  
Vol 114 (4) ◽  
pp. 847-857 ◽  
Author(s):  
J. H. Wagner ◽  
B. V. Johnson ◽  
R. A. Graziani ◽  
F. C. Yeh

Experiments were conducted to determine the effects of buoyancy and Coriolis forces on heat transfer in turbine blade internal coolant passages. The experiments were conducted with a large-scale, multipass, heat transfer model with both radially inward and outward flow. Trip strips on the leading and trailing surfaces of the radial coolant passages were used to produce the rough walls. An analysis of the governing flow equations showed that four parameters influence the heat transfer in rotating passages: coolant-to-wall temperature ratio, Rossby number, Reynolds number, and radius-to-passage hydraulic diameter ratio. The first three of these four parameters were varied over ranges that are typical of advanced gas turbine engine operating conditions. Results were correlated and compared to previous results from stationary and rotating similar models with trip strips. The heat transfer coefficients on surfaces, where the heat transfer increased with rotation and buoyancy, varied by as much as a factor of four. Maximum values of the heat transfer coefficients with high rotation were only slightly above the highest levels obtained with the smooth wall model. The heat transfer coefficients on surfaces where the heat transfer decreased with rotation, varied by as much as a factor of three due to rotation and buoyancy. It was concluded that both Coriolis and buoyancy effects must be considered in turbine blade cooling designs with trip strips and that the effects of rotation were markedly different depending upon the flow direction.


1984 ◽  
Vol 106 (1) ◽  
pp. 55-63 ◽  
Author(s):  
P. Souza Mendes ◽  
E. M. Sparrow

A comprehensive experimental study was performed to determine entrance region and fully developed heat transfer coefficients, pressure distributions and friction factors, and patterns of fluid flow in periodically converging and diverging tubes. The investigated tubes consisted of a succession of alternately converging and diverging conical sections (i.e., modules) placed end to end. Systematic variations were made in the Reynolds number, the taper angle of the converging and diverging modules, and the module aspect ratio. Flow visualizations were performed using the oil-lampblack technique. A performance analysis comparing periodic tubes and conventional straight tubes was made using the experimentally determined heat transfer coefficients and friction factors as input. For equal mass flow rate and equal transfer surface area, there are large enhancements of the heat transfer coefficient for periodic tubes, with accompanying large pressure drops. For equal pumping power and equal transfer surface area, enhancements in the 30–60 percent range were encountered. These findings indicate that periodic converging-diverging tubes possess favorable enhancement characteristics.


1983 ◽  
Vol 105 (4) ◽  
pp. 851-861 ◽  
Author(s):  
E. M. Sparrow ◽  
W. Q. Tao

Experiments were performed in a flat rectangular duct to determine the heat transfer and pressure drop response to periodic, rod-type disturbance elements situated adjacent to one principal wall and oriented transverse to the flow direction. In a portion of the experiments, heat transfer occurred only at the rodded wall, while in the remainder, heat was transferred at both principal walls of the duct. Highly detailed axial distributions of the local heat transfer coefficient were obtained. These distributions revealed the rapid establishment of a periodic (i.e., cyclic) fully developed regime as well as recurring local maxima and minima. Cycle-average, fully developed heat transfer coefficients were evaluated and were found to be much larger than those for a smooth-walled duct. Linear pressure distributions were measured between periodically positioned stations in the fully developed region, and the corresponding friction factors were several times greater than the smooth-duct values. The heat transfer and friction data were very well correlated using parameters that take account of the effective surface roughness associated with the disturbance rods.


2001 ◽  
Vol 123 (6) ◽  
pp. 1149-1158 ◽  
Author(s):  
X. D. Chen ◽  
X. Y. Xu ◽  
S. K. Nguang ◽  
Arthur E. Bergles

A series of four-start spirally corrugated tubes has been subjected to heat transfer and hydrodynamic testing in a double-pipe heat exchanger. The study has been focused on the non-symmetric nature of the corrugation angles along the longitudinal direction. Both friction factors and heat transfer coefficients inside the tubes have been correlated against various process parameters. It can be shown that by altering the internal non-symmetric wavy shapes of the tubes, one is able to manipulate heat transfer and friction characteristics. The experimental results have been compared with some popular correlation models developed previously for both friction and heat transfer for corrugated tubes. Considerable differences between the experimental results and the predictions made using the existing correlations have been found and the probable causes have been discussed. Performance evaluation criteria are presented using the standard constant power criterion. A neural network modeling approach has been taken so that, based on the limited data, one can generate the contour showing the effect of corrugation angle on heat transfer coefficient for geometry optimization purposes.


2003 ◽  
Vol 125 (2) ◽  
pp. 274-280 ◽  
Author(s):  
H. K. Moon ◽  
T. O’Connell ◽  
R. Sharma

The heat transfer rate from a smooth wall in an internal cooling passage can be significantly enhanced by using a convex patterned surface on the opposite wall of the passage. This design is particularly effective for a design that requires the heat transfer surface to be free of any augmenting features (smooth). Heat transfer coefficients on the smooth wall in a rectangular channel, which had convexities on the opposite wall were experimentally investigated. Friction factors were also measured to assess the thermal performance. Relative clearances δ/d between the convexities and the smooth wall of 0, 0.024, and 0.055 were investigated in a Reynolds number ReHD range from 15,000 to 35,000. The heat transfer coefficients were measured in the thermally developed region using a transient thermochromic liquid crystal technique. The clearance gap between the convexities and the smooth wall adversely affected the heat transfer enhancement NuHD. The friction factors (f ), measured in the aerodynamically developed region, were largest for the cases of no clearance δ/d=0). The average heat transfer enhancement Nu¯HD was also largest for the cases of no clearance δ/d=0, as high as 3.08 times at a Reynolds number of 11,456 in relative to that Nuo of an entirely smooth channel. The normalized Nusselt numbers Nu¯HD/Nuo, as well as the normalized friction factors f/fo, for all three cases, decreased with Reynolds numbers. However, the decay rate of the friction factor ratios f/fo with Reynolds numbers was lower than that of the normalized Nusselt numbers. For all three cases investigated, the thermal performance Nu¯HD/Nuo/f/fo1/3 values were within 5% to each other. The heat transfer enhancement using a convex patterned surface was thermally more effective at a relative low Reynolds numbers (less than 20,000 for δ/d=0) than that of a smooth channel.


2013 ◽  
Vol 135 (7) ◽  
Author(s):  
Mehmed Rafet Özdemir ◽  
Ali Koşar

The pressure drop and heat transfer due to the flow of de-ionized water at high mass fluxes in microtubes of ∼ 254 μm and ∼ 685 μm inner diameters is investigated in the laminar, transition and the turbulent flow regimes. The flow is hydrodynamically fully developed and thermally developing. The experimental friction factors and heat transfer coefficients are respectively predicted to within ±20% and ±30% by existing open literature correlations. Higher single phase heat transfer coefficients were obtained with increasing mass fluxes, which is motivating to operate at high mass fluxes and under thermally developing flow conditions. The transition to turbulent flow and friction factors for both laminar and turbulent conditions were found to be in agreement with existing theory. A reasonable agreement was present between experimental results and theoretical predictions recommended for convective heat transfer in thermally developing flows.


Author(s):  
S. Acharya ◽  
Fuguo Zhou ◽  
Jonathan Lagrone ◽  
Gazi Mahmood ◽  
Ronald S. Bunker

The heat transfer and pressure drop characteristics of latticework coolant blade passages have been investigated experimentally under conditions of rotation. Stationary studies with the latticework configuration have shown potential advantages including spatially-uniform streamwise distributions of the heat transfer coefficient, greater blade strength, and enhancement levels comparable to conventional rib turbulators. In the present study, a latticework coolant passage, with orthogonal-ribs, is studied in a rotating heat transfer test-rig for a range of Reynolds numbers (Res), Rotation numbers (Ros), and density ratios. Measurements indicate that for Res≥20,000, the latticework coolant passage provides very uniform streamwise distributions of the Nusselt number (Nus) with enhancement levels (relative to smooth-channel values) in the range of 2.0 to 2.5. No significant dependence of Nus on Ros and density ratio is observed except at lower Res values (≤10,000). Nusselt numbers are highest immediately downstream of a turn indicating that bend-effects play a major role in enhancing heat transfer. Friction factors are relatively insensitive to Ros, and thermal performance factors at higher Res values appear to be comparable to those obtained with conventional rib-turbulators. The present study indicates that latticework cooling geometry can provide comparable heat transfer enhancements and thermal performance factors as conventional rib-turbulators, with potential benefits of streamwise uniformity in the heat transfer coefficients and added blade strength.


Author(s):  
Ronald S. Bunker ◽  
Sarah J. Osgood

An experimental study has been performed to investigate the convective heat transfer coefficients and friction factors present in square cooling passages with non-normal, or leaned turbulators. The standard form of turbulated channels used in virtually all turbine vanes and blades is that of nearly square turbulators, or rib rougheners, cast in an orthogonal orientation to the channel surface. While turbulators may be oriented at an angle to the bulk flow direction, the projection of the turbulator is still normal to the cast surface. Non-orthogonal lean angle presents an additional variable which may be used to improve or optimize performance, a factor hitherto not investigated. The present study has performed a series of experiments measuring both detailed heat transfer coefficient distributions and friction factors within a square channel with flow Reynolds numbers up to 400,000. Turbulator lean angles of 45, 22.5, 0, −22.5, and −45-degrees to the surface normal have been tested with a turbulator configuration of 45-degree orientation to the bulk flow, pitch-to-height ratio of 10, and height-to-hydraulic diameter ratio of 0.1. Results show up to a 20% reduction in heat transfer capability, and as much as 30% increase in friction factor. The local distributions of heat transfer are also more variable with lean angle. The conclusion is made that normal turbulators provide the best overall performance.