Field-based fault architecture of fold-thrust belts: an example from the Qaidam basin, northeast Tibetan Plateau

Author(s):  
Yangwen Pei

<p>Understanding the detailed fault architecture of reverse faulting is not only critical for revealing the processes involved in fold-thrust belts as well as predicting the relationship between folds and faults, the distribution of strain, and sub-seismic faulting deformation, but also important for understanding fault related compartmentalisation and fluid flow behaviour both along and/or across thrust fault zones. The Lenghu5 fold-thrust belt, provides an exceptionally well-exposed outcrop example of a reverse fault-related fold. Detailed stratigraphic logging coupled with high-resolution cross-sections provides a unique insight into the 3D geometry of a thrust fault at both basin and outcrop scale.</p><p>In this study we observed 85 - 90% of the estimated throw is accommodated on the main fault zone (i.e., the Lenghu5 thrust fault), which has sufficient throw to be imaged on a seismic profile, while 15-20% of the throw is accommodated on smaller scale folds and faults that are beyond seismic resolution. The Lenghu5 thrust fault, a seismically resolvable fault with up to ~800m of throw, exhibits a large variation of fault architecture and strain distribution along the fault zone. As meso-scale (1-100 m) structural features are normally beyond the seismic resolution, high-resolution outcrop in-situ mapping (5-10 cm resolution) was employed to study the deformation features of the Lenghu5 thrust fault zone. The excellent exposure of outcrops enables detailed investigation of its fault zone architecture. Multiple structural domains with different levels of strain were observed and are associated with the fault throw distribution across the fault. Based on previously proposed models and high-resolution outcrop mapping, an updated fault zone model was constructed to characterize the structural features and evolution of the Lenghu5 thrust fault.</p><p>The possible parameters that impact fault architecture and strain distribution, including fault throw, bed thickness, lithology and mechanical heterogeneity were evaluated. Fault throw distributions and linkages control the strain distribution across a thrust fault zone, with local folding processes contributing important elements in the Lenghu5 thrust fault especially where more incompetent beds dominate the stratigraphy. Mechanical heterogeneity, induced by different layer stacking patterns, controls the details of the fault architecture in the thrust zone. The variations in bed thicknesses and mechanical property contrasts are likely to control the initial fault dips and fault/fracture density. Large fault throws are associated with wide strain accommodation and damage zones, although the relationship between the development and width of the fault zone with the throw accumulation remains to be assessed.</p><p>By presenting the high resolution mapping of fault architecture this study provides an insight into the sub-seismic fault zone geometry and strain distributions possible in thrust faults and reviews their application to assessing fault zone behaviour.</p>

2019 ◽  
Vol 132 (1-2) ◽  
pp. 389-408 ◽  
Author(s):  
Yangwen Pei ◽  
Douglas A. Paton ◽  
Rob J. Knipe ◽  
W. Henry Lickorish ◽  
Anren Li ◽  
...  

AbstractThe fault zone architecture of a thrust fault zone is critical for understanding the strain accommodation and structural evolution in contractional systems. The fault architecture is also important for understanding fluid-flow behavior both along and/or across thrust fault zones and for evaluating potential fault-related compartmentalization. Because mesoscale (1–100 m) structural features are normally beyond seismic resolution, high-resolution outcrop in situ mapping (5–10 cm resolution) was employed to study the deformation features of a thrust fault zone located in the Qaidam Basin, northeastern Tibetan Plateau. The excellent exposure of outcrops enables the detailed investigation of the Lenghu thrust fault zone and its architecture. The Lenghu thrust fault, a seismically resolvable fault with up to ∼800 m of throw, exhibits a large variation of fault architecture and strain distribution along the fault zone. Multiple structural domains with different levels of strain were observed and are associated with the fault throw distribution across the fault. Based on previously proposed models and high-resolution outcrop mapping, an updated fault zone model was constructed to characterize the structural features and evolution of the Lenghu thrust. The possible parameters that impact fault architecture and strain distribution, including fault throw, bed thickness, lithology, and mechanical heterogeneity, were evaluated. Fault throw distributions and linkages control the strain distribution across a thrust fault zone, with local folding processes contributing important elements in Lenghu, especially where more incompetent beds dominate the stratigraphy. Mechanical heterogeneity, induced by different layer stacking patterns, controls the details of the fault architecture in the thrust zone. The variations in bed thicknesses and mechanical property contrasts are likely to control the initial fault dips and fault/fracture density. Large fault throws are associated with wide strain accommodation and damage zones, although the relationship between the development and width of the fault zone and the throw accumulation remains to be assessed. By presenting the high-resolution mapping of fault architecture, this study provides an insight into the subseismic fault zone geometry and strain distributions possible in thrust faults and reviews their application to assessments of fault zone behavior.


Author(s):  
D. F. Blake ◽  
L. F. Allard ◽  
D. R. Peacor

Echinodermata is a phylum of marine invertebrates which has been extant since Cambrian time (c.a. 500 m.y. before the present). Modern examples of echinoderms include sea urchins, sea stars, and sea lilies (crinoids). The endoskeletons of echinoderms are composed of plates or ossicles (Fig. 1) which are with few exceptions, porous, single crystals of high-magnesian calcite. Despite their single crystal nature, fracture surfaces do not exhibit the near-perfect {10.4} cleavage characteristic of inorganic calcite. This paradoxical mix of biogenic and inorganic features has prompted much recent work on echinoderm skeletal crystallography. Furthermore, fossil echinoderm hard parts comprise a volumetrically significant portion of some marine limestones sequences. The ultrastructural and microchemical characterization of modern skeletal material should lend insight into: 1). The nature of the biogenic processes involved, for example, the relationship of Mg heterogeneity to morphological and structural features in modern echinoderm material, and 2). The nature of the diagenetic changes undergone by their ancient, fossilized counterparts. In this study, high resolution TEM (HRTEM), high voltage TEM (HVTEM), and STEM microanalysis are used to characterize tha ultrastructural and microchemical composition of skeletal elements of the modern crinoid Neocrinus blakei.


Author(s):  
Robert M. Glaeser

It is well known that a large flux of electrons must pass through a specimen in order to obtain a high resolution image while a smaller particle flux is satisfactory for a low resolution image. The minimum particle flux that is required depends upon the contrast in the image and the signal-to-noise (S/N) ratio at which the data are considered acceptable. For a given S/N associated with statistical fluxtuations, the relationship between contrast and “counting statistics” is s131_eqn1, where C = contrast; r2 is the area of a picture element corresponding to the resolution, r; N is the number of electrons incident per unit area of the specimen; f is the fraction of electrons that contribute to formation of the image, relative to the total number of electrons incident upon the object.


Author(s):  
P. A. Marsh ◽  
T. Mullens ◽  
D. Price

It is possible to exceed the guaranteed resolution on most electron microscopes by careful attention to microscope parameters essential for high resolution work. While our experience is related to a Philips EM-200, we hope that some of these comments will apply to all electron microscopes.The first considerations are vibration and magnetic fields. These are usually measured at the pre-installation survey and must be within specifications. It has been our experience, however, that these factors can be greatly influenced by the new facilities and therefore must be rechecked after the installation is completed. The relationship between the resolving power of an EM-200 and the maximum tolerable low frequency interference fields in milli-Oerstedt is 10 Å - 1.9, 8 Å - 1.4, 6 Å - 0.8.


2018 ◽  
Vol 71 (0) ◽  
pp. 33-42
Author(s):  
Shigeru Ino ◽  
Shigeyuki Suda ◽  
Hidekuni Kikuchi ◽  
Shiro Ohkawa ◽  
Shintaro Abe ◽  
...  

2009 ◽  
Author(s):  
Ray W. Sliter ◽  
Peter J. Triezenberg ◽  
Patrick E. Hart ◽  
Janet T. Watt ◽  
Samuel Y. Johnson ◽  
...  

2020 ◽  
Vol 132 (5) ◽  
pp. 1358-1366
Author(s):  
Chao-Hung Kuo ◽  
Timothy M. Blakely ◽  
Jeremiah D. Wander ◽  
Devapratim Sarma ◽  
Jing Wu ◽  
...  

OBJECTIVEThe activation of the sensorimotor cortex as measured by electrocorticographic (ECoG) signals has been correlated with contralateral hand movements in humans, as precisely as the level of individual digits. However, the relationship between individual and multiple synergistic finger movements and the neural signal as detected by ECoG has not been fully explored. The authors used intraoperative high-resolution micro-ECoG (µECoG) on the sensorimotor cortex to link neural signals to finger movements across several context-specific motor tasks.METHODSThree neurosurgical patients with cortical lesions over eloquent regions participated. During awake craniotomy, a sensorimotor cortex area of hand movement was localized by high-frequency responses measured by an 8 × 8 µECoG grid of 3-mm interelectrode spacing. Patients performed a flexion movement of the thumb or index finger, or a pinch movement of both, based on a visual cue. High-gamma (HG; 70–230 Hz) filtered µECoG was used to identify dominant electrodes associated with thumb and index movement. Hand movements were recorded by a dataglove simultaneously with µECoG recording.RESULTSIn all 3 patients, the electrodes controlling thumb and index finger movements were identifiable approximately 3–6-mm apart by the HG-filtered µECoG signal. For HG power of cortical activation measured with µECoG, the thumb and index signals in the pinch movement were similar to those observed during thumb-only and index-only movement, respectively (all p > 0.05). Index finger movements, measured by the dataglove joint angles, were similar in both the index-only and pinch movements (p > 0.05). However, despite similar activation across the conditions, markedly decreased thumb movement was observed in pinch relative to independent thumb-only movement (all p < 0.05).CONCLUSIONSHG-filtered µECoG signals effectively identify dominant regions associated with thumb and index finger movement. For pinch, the µECoG signal comprises a combination of the signals from individual thumb and index movements. However, while the relationship between the index finger joint angle and HG-filtered signal remains consistent between conditions, there is not a fixed relationship for thumb movement. Although the HG-filtered µECoG signal is similar in both thumb-only and pinch conditions, the actual thumb movement is markedly smaller in the pinch condition than in the thumb-only condition. This implies a nonlinear relationship between the cortical signal and the motor output for some, but importantly not all, movement types. This analysis provides insight into the tuning of the motor cortex toward specific types of motor behaviors.


Sign in / Sign up

Export Citation Format

Share Document