scholarly journals Long-term groundwater recharge rates across India by in situ measurements

2019 ◽  
Vol 23 (2) ◽  
pp. 711-722 ◽  
Author(s):  
Soumendra N. Bhanja ◽  
Abhijit Mukherjee ◽  
R. Rangarajan ◽  
Bridget R. Scanlon ◽  
Pragnaditya Malakar ◽  
...  

Abstract. Groundwater recharge sustains groundwater discharge, including natural discharge through springs and the base flow to surface water as well as anthropogenic discharge through pumping wells. Here, for the first time, we compute long-term (1996–2015) groundwater recharge rates using data retrieved from several groundwater-level monitoring locations across India (3.3 million km2 area), the most groundwater-stressed region globally. Spatial variations in groundwater recharge rates (basin-wide mean: 17 to 960 mm yr−1) were estimated in the 22 major river basins across India. The extensive plains of the Indus–Ganges–Brahmaputra (IGB) river basins are subjected to prevalence of comparatively higher recharge. This is mainly attributed to occurrence of coarse sediments, higher rainfall, and intensive irrigation-linked groundwater-abstraction inducing recharge by increasing available groundwater storage and return flows. Lower recharge rates (<200 mm yr−1) in most of the central and southern study areas occur in cratonic, crystalline fractured aquifers. Estimated recharge rates have been compared favorably with field-scale recharge estimates (n=52) based on tracer (tritium) injection tests. Results show that precipitation rates do not significantly influence groundwater recharge in most of the river basins across India, indicating human influence in prevailing recharge rates. The spatial variability in recharge rates could provide critical input for policymakers to develop more sustainable groundwater management in India.

2018 ◽  
Author(s):  
Soumendra N. Bhanja ◽  
Abhijit Mukherjee ◽  
Rangarajan Ramaswamy ◽  
Bridget R. Scanlon ◽  
Pragnaditya Malakar ◽  
...  

Abstract. Groundwater recharge sustains groundwater discharge, including natural discharge through springs and base flow to surface water as well as anthropogenic discharge through pumping wells. Here, for the first time, we compute long-term (1996–2015) groundwater recharge rates using data retrieved from several groundwater level monitoring locations across India (3.3 million km2 area), the most groundwater-stressed region globally. Spatial variations in groundwater recharge rates (basin-wide mean: 17 to 960 mm/yr) were estimated in the 22 major river basins across India. The extensive plains of the Indus–Ganges–Brahmaputra (IGB) river basins are subjected to prevalence of comparatively higher recharge. This is mainly attributed to occurrence of coarse sediments, higher rainfall, and intensive irrigation-linked groundwater abstraction inducing recharge by increasing available groundwater storage and return flows. Lower recharge rates (


Author(s):  
Yanhui Dong ◽  
Yueqing Xie ◽  
Jun Zhang ◽  
Andy Love ◽  
Xin Dai

Groundwater age is often used to estimate groundwater recharge through a simplified analytical approach. This estimated recharge is thought to be representative of the mean recharge between the point of entry and the sampling point. However, given the complexity in actual recharge, whether the mean recharge is reasonable is still unclear. This study examined the validity of the method to estimate long-term average groundwater recharge and the possibility of obtaining reasonable spatial recharge pattern. We first validated our model in producing reasonable age distributions using a constant flux boundary condition. We then generated different flow fields and age patterns by using various spatially-varying flux boundary conditions with different magnitudes and wavelengths. Groundwater recharge was estimated and analyzed afterwards using the method at the spatial scale. We illustrated the main findings with a field example in the end. Our results suggest that we can estimate long-term average groundwater recharge with 10% error in many parts of an aquifer. The size of these areas decreases with the increase in both the amplitude and the wavelength. The chance of obtaining a reasonable groundwater recharge is higher if an age sample is collected from the middle of an aquifer and at downstream areas. Our study also indicates that the method can also be used to estimate local groundwater recharge if age samples are collected close to the water table. However, care must be taken to determine groundwater age regardless of conditions.


2020 ◽  
Vol 163 ◽  
pp. 04001
Author(s):  
Vladimir Alexeev ◽  
Olga Makarieva ◽  
Andrey Shikhov ◽  
Nataliia Nesterova ◽  
Andrey Ostashov ◽  
...  

This study presents the results of development of the Catalogue and Atlas of giant aufeis-taryns in the North-East of Russia. The characteristics of aufeis in the North-East of Russia for the last 70 years have been generalized and systematized into the Catalogue database using data from the Cadastre of aufeis (1958) and Landsat images for the period 2013-2017 for the Yana, Indigirka, Kolyma River basins and Chukotka area. In total the territory more than 1.9 million km2 is covered by the study. The Catalogue contains the information about the location and characteristics of more than 4600 aufeis fields. The release of the Atlas of aufeis-taryns in the North-East of Russia has been announced. It reveals the history of study, origin, distribution, and specific features of aufeis and is supplemented with medium- and large-scale maps of aufeis with their seasonal and long-term dynamics.


2021 ◽  
Author(s):  
Charles West ◽  
Rafael Rosolem ◽  
Alan MacDonald ◽  
Mark Cuthbert ◽  
Thorsten Wagener

Groundwater is critical in supporting current and future reliable water supply throughout Africa. Although continental maps of groundwater storage and recharge have been developed, we currently lack a clear understanding on how the controls on groundwater recharge vary across the entire continent. Reviewing the existing literature, we synthesize information on reported groundwater recharge controls in Africa. We find that 15 out of 22 of these controls can be characterised using global datasets. We develop 11 descriptors of climatic, topographic, vegetation, soil and geologic properties using global datasets, to characterise groundwater recharge controls in Africa. These descriptors cluster Africa into 15 Recharge Landscape Units for which we expect recharge controls to be similar. Over 80% of the continents land area is organized by just nine of these units. We also find that aggregating the Units by similarity into four broader Recharge Landscapes (Desert, Dryland, Wet tropical and Wet tropical forest) provides a suitable level of landscape organisation to explain differences in ground-based long-term mean annual recharge and recharge ratio estimates. Furthermore, wetter Recharge Landscapes are more efficient in converting rainfall to recharge than drier Recharge Landscapes as well as having higher annual recharge rates. In Dryland Recharge Landscapes, we found that annual recharge rates largely varied according to mean annual precipitation, whereas recharge ratio estimates increase with increasing monthly variability in P-PET. However, we were unable to explain why ground-based estimates of recharge signatures vary across other Recharge Landscapes, in which there are fewer ground-based recharge estimates, using global datasets alone. Even in dryland regions, there is still considerable unexplained variability in the estimates of annual recharge and recharge ratio, stressing the limitations of global datasets for investigating ground-based information.


Author(s):  
Soumendra N. Bhanja ◽  
Abhijit Mukherjee ◽  
Rangarajan Ramaswamy ◽  
Bridget R. Scanlon ◽  
Pragnaditya Malakar ◽  
...  

Rheumatology ◽  
2021 ◽  
Author(s):  
Yuichi Yamasaki ◽  
Norimoto Kobayashi ◽  
Shinji Akioka ◽  
Kazuko Yamazaki ◽  
Shunichiro Takezaki ◽  
...  

Abstract Objectives This study aimed to investigate the clinical characteristics, treatment and prognosis of juvenile idiopathic inflammatory myopathies (JIIM) in Japan for each myositis-specific autoantibody (MSA) profile. Methods A multicentre, retrospective study was conducted using data of patients with JIIM at nine paediatric rheumatology centres in Japan. Patients with MSA profiles, determined by immunoprecipitation using stored serum from the active stage, were included. Results MSA were detected in 85 of 96 cases eligible for the analyses. Over 90% of the patients in this study had one of the following three MSA types: anti-melanoma differentiation-associated protein 5 (MDA5) (n = 31), anti-transcriptional intermediary factor 1 alpha and/or gamma subunits (TIF1γ) (n = 25) and anti-nuclear matrix protein 2 (NXP2) (n = 25) antibodies. Gottron papules and periungual capillary abnormalities were the most common signs of every MSA group in the initial phase. The presence of interstitial lung disease (ILD) was the highest risk factor for patients with anti-MDA5 antibodies. Most patients were administered multiple drug therapies: glucocorticoids and MTX were administered to patients with anti-TIF1γ or anti-NXP2 antibodies. Half of the patients with anti-MDA5 antibodies received more than three medications including i.v. CYC, especially patients with ILD. Patients with anti-MDA5 antibodies were more likely to achieve drug-free remission (29 vs 21%) and less likely to relapse (26 vs 44%) than others. Conclusion Anti-MDA5 antibodies are the most common MSA type in Japan, and patients with this antibody are characterized by ILD at onset, multiple medications including i.v. CYC, drug-free remission, and a lower frequency of relapse. New therapeutic strategies are required for other MSA types.


2021 ◽  
pp. 1420326X2110036
Author(s):  
Qian Xu ◽  
Chan Lu ◽  
Rachael Gakii Murithi ◽  
Lanqin Cao

A cohort case–control study was conducted in XiangYa Hospital, Changsha, China, which involved 305 patients and 399 healthy women, from June 2010 to December 2018, to evaluate the association between Chinese women’s short- and long-term exposure to industrial air pollutant, SO2 and gynaecological cancer (GC). We obtained personal and family information from the XiangYa Hospital electronic computer medical records. Using data obtained from the air quality monitoring stations in Changsha, we estimated each woman’s exposure to the industrial air pollutant, sulphur dioxide (SO2), for different time windows, including the past 1, 5, 10 and 15 years before diagnosis of the disease. A multiple logistic regression model was used to assess the association between GC and SO2 exposure. GC was significantly associated with long-term SO2 exposure, with adjusted odds ratio (95% confidence interval) = 1.56 (1.10–2.21) and 1.81 (1.07–3.06) for a per interquartile range increase in the past 10 and 15 years, respectively. Sensitivity analysis showed that different groups reacted in different ways to long-term SO2 exposure. We concluded that long-term exposure to high concentration of industrial pollutant, SO2 is associated with the development of GC. This finding has implications for the prevention and reduction of GC.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Bohan Liu ◽  
Pan Liu ◽  
Lutao Dai ◽  
Yanlin Yang ◽  
Peng Xie ◽  
...  

AbstractThe pandemic of Coronavirus Disease 2019 (COVID-19) is causing enormous loss of life globally. Prompt case identification is critical. The reference method is the real-time reverse transcription PCR (RT-PCR) assay, whose limitations may curb its prompt large-scale application. COVID-19 manifests with chest computed tomography (CT) abnormalities, some even before the onset of symptoms. We tested the hypothesis that the application of deep learning (DL) to 3D CT images could help identify COVID-19 infections. Using data from 920 COVID-19 and 1,073 non-COVID-19 pneumonia patients, we developed a modified DenseNet-264 model, COVIDNet, to classify CT images to either class. When tested on an independent set of 233 COVID-19 and 289 non-COVID-19 pneumonia patients, COVIDNet achieved an accuracy rate of 94.3% and an area under the curve of 0.98. As of March 23, 2020, the COVIDNet system had been used 11,966 times with a sensitivity of 91.12% and a specificity of 88.50% in six hospitals with PCR confirmation. Application of DL to CT images may improve both efficiency and capacity of case detection and long-term surveillance.


2020 ◽  
Vol 13 ◽  
pp. 175628642092268 ◽  
Author(s):  
Francesco Patti ◽  
Andrea Visconti ◽  
Antonio Capacchione ◽  
Sanjeev Roy ◽  
Maria Trojano ◽  
...  

Background: The CLARINET-MS study assessed the long-term effectiveness of cladribine tablets by following patients with multiple sclerosis (MS) in Italy, using data from the Italian MS Registry. Methods: Real-world data (RWD) from Italian MS patients who participated in cladribine tablets randomised clinical trials (RCTs; CLARITY, CLARITY Extension, ONWARD or ORACLE-MS) across 17 MS centres were obtained from the Italian MS Registry. RWD were collected during a set observation period, spanning from the last dose of cladribine tablets during the RCT (defined as baseline) to the last visit date in the registry, treatment switch to other disease-modifying drugs, date of last Expanded Disability Status Scale recording or date of the last relapse (whichever occurred last). Time-to-event analysis was completed using the Kaplan–Meier (KM) method. Median duration and associated 95% confidence intervals (CI) were estimated from the model. Results: Time span under observation in the Italian MS Registry was 1–137 (median 80.3) months. In the total Italian patient population ( n = 80), the KM estimates for the probability of being relapse-free at 12, 36 and 60 months after the last dose of cladribine tablets were 84.8%, 66.2% and 57.2%, respectively. The corresponding probability of being progression-free at 60 months after the last dose was 63.7%. The KM estimate for the probability of not initiating another disease-modifying treatment at 60 months after the last dose of cladribine tablets was 28.1%, and the median time-to-treatment change was 32.1 (95% CI 15.5–39.5) months. Conclusion: CLARINET-MS provides an indirect measure of the long-term effectiveness of cladribine tablets. Over half of MS patients analysed did not relapse or experience disability progression during 60 months of follow-up from the last dose, suggesting that cladribine tablets remain effective in years 3 and 4 after short courses at the beginning of years 1 and 2.


Sign in / Sign up

Export Citation Format

Share Document