scholarly journals Structural behaviour and design of cold-formed steel hollow section columns under simulated fire conditions

Author(s):  
Manuvidhya Balarupan
Fire Research ◽  
2016 ◽  
Author(s):  
Hélder D. Craveiro ◽  
João Paulo C. Rodrigues ◽  
Luís M. Laím

Cold-formed steel (CFS) profiles with a wide range of cross-section shapes are commonly used in building construction industry. Nowadays several cross-sections can be built using the available standard single sections (C, U, Σ, etc.), namely open built-up and closed built-up cross-sections. This paper reports an extensive experimental investigation on the behavior of single and built-up cold-formed steel columns at both ambient and simulated fire conditions considering the effect of restraint to thermal elongation. The buckling behavior, ultimate loads and failure modes, of different types of CFS columns at both ambient and simulated fire conditions with restraint to thermal elongation, are presented and compared. Regarding the buckling tests at ambient temperature it was observed that the use of built-up cross-sections ensures significantly higher values of buckling loads. Especially for the built-up cross-sections the failure modes were characterized by the interaction of individual buckling modes, namely flexural about the minor axis, distortional and local buckling. Regarding the fire tests, it is clear that the same levels of restraint used in the experimental investigation induce different rates in the generated restraining forces due to thermal elongation of the columns. Another conclusion that can be drawn from the results is that by increasing the level of restraint to thermal elongation the failure of the columns is controlled by the generated restraining forces, whereas for lower levels of restraint the temperature plays a more important role. Hence, higher levels of imposed restraint to thermal elongation will lead to higher values of generated restraining forces and eventually to lower values of critical temperature and time.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Kun Liu ◽  
Wei Chen ◽  
Jihong Ye ◽  
Jian Jiang ◽  
Wenwen Chen ◽  
...  

Purpose Most previous thermal-mechanical modeling of cold-formed steel (CFS) walls did not consider the failure of screwed connections under fire conditions because of the limited data of such connections at elevated temperatures. Design/methodology/approach In this study, 285 steady-state tests are conducted on CFS screwed connections with single-layer gypsum plasterboard (GPB) and Bolivian magnesium board (BMB) sheathing at ambient and elevated temperatures. The failure of these connections is described as the breaking of the loaded sheathing edge. Findings For the BMB sheathing screwed connections, hydrochloric acid gas is generated and released above 300°C, and the shear strength becomes much less than that of the GPB sheathing screwed connection above 370°C. Hence, BMB may not be suitable for use as the face-layer sheathing of CFS walls but is still recommended to replace GPB as the base-layer sheathing. The major influencing parameters on the shear strength of screwed connections are identified as the type of sheathing material and the loaded sheathing edge distance. Originality/value Based on the previous and present test results, a unified expression for the residual shear strength of screwed connections with GPB and BMB is proposed at ambient and elevated temperatures with acceptable accuracy. It can be used as the basic input parameter of the numerical simulation of the CFS structures under fire conditions.


2020 ◽  
Vol 114 ◽  
pp. 102993 ◽  
Author(s):  
Jolanta Bączkiewicz ◽  
Mikko Malaska ◽  
Sami Pajunen ◽  
Mika Alanen ◽  
Markku Heinisuo

Sign in / Sign up

Export Citation Format

Share Document