Studies of the internal structure of electrical devices and the archaeological heritage by the method of neutron radiography and tomography

2021 ◽  
Vol 23 (3) ◽  
pp. 63-67
Author(s):  
M.Yu. Tashmetov ◽  
B.S. Yuldashev ◽  
S.M. Adizov ◽  
N.B. Ismatov

The paper presents the results of the study of a series of objects of electrical devices and archaeological heritage by the method of neutron radiography and tomography (VL-10 diode, spark plug, bell, ancient ring, stone). It is shown that the method of neutron radiography and tomography reliably works on samples made of various materials. Neutron radiographic and tomographic studies of the VL-10 diode gave an idea of the internal structure of the diode. Experiments with spark plugs have revealed the causes of its faulty function. According to the tomographic results of the bell, ring and stone, the heterogeneous areas in the internal volume of these objects were revealed. The results obtained are the basis for further research in the field of archaeological heritage and technical devices for special purposes.

2014 ◽  
Vol 73 ◽  
pp. 171-179 ◽  
Author(s):  
Wanzhao Li ◽  
Jan Van den Bulcke ◽  
David Mannes ◽  
Eberhard Lehmann ◽  
Imke De Windt ◽  
...  

2021 ◽  
Vol 66 (2) ◽  
pp. 254-266
Author(s):  
K. M. Podurets ◽  
S. E. Kichanov ◽  
V. P. Glazkov ◽  
E. S. Kovalenko ◽  
M. M. Murashev ◽  
...  

Author(s):  
H.W. Deckman ◽  
B.F. Flannery ◽  
J.H. Dunsmuir ◽  
K.D' Amico

We have developed a new X-ray microscope which produces complete three dimensional images of samples. The microscope operates by performing X-ray tomography with unprecedented resolution. Tomography is a non-invasive imaging technique that creates maps of the internal structure of samples from measurement of the attenuation of penetrating radiation. As conventionally practiced in medical Computed Tomography (CT), radiologists produce maps of bone and tissue structure in several planar sections that reveal features with 1mm resolution and 1% contrast. Microtomography extends the capability of CT in several ways. First, the resolution which approaches one micron, is one thousand times higher than that of the medical CT. Second, our approach acquires and analyses the data in a panoramic imaging format that directly produces three-dimensional maps in a series of contiguous stacked planes. Typical maps available today consist of three hundred planar sections each containing 512x512 pixels. Finally, and perhaps of most import scientifically, microtomography using a synchrotron X-ray source, allows us to generate maps of individual element.


Author(s):  
D. R. Liu ◽  
S. S. Shinozaki ◽  
J. S. Park ◽  
B. N. Juterbock

The electric and thermal properties of the resistor material in an automotive spark plug should be stable during its service lifetime. Containing many elements and many phases, this material has a very complex microstructure. Elemental mapping with an electron microprobe can reveal the distribution of all relevant elements throughout the sample. In this work, it is demonstrated that the charge-up effect, which would distort an electron image and, therefore, is normally to be avoided in an electron imaging work, could be used to advantage to reveal conductive and resistive zones in a sample. Its combination with elemental mapping can provide valuable insight into the underlying conductivity mechanism of the resistor.This work was performed in a CAMECA SX-50 microprobe. The spark plug used in the present report was a commercial product taken from the shelf. It was sectioned to expose the cross section of the resistor. The resistor was known not to contain the precious metal Au as checked on the carbon coated sample. The sample was then stripped of carbon coating and re-coated with Au.


Author(s):  
Leo Barish

Although most of the wool used today consists of fine, unmedullated down-type fibers, a great deal of coarse wool is used for carpets, tweeds, industrial fabrics, etc. Besides the obvious diameter difference, coarse wool fibers are often medullated.Medullation may be easily observed using bright field light microscopy. Fig. 1A shows a typical fine diameter nonmedullated wool fiber, Fig. IB illustrates a coarse fiber with a large medulla. The opacity of the medulla is due to the inability of the mounting media to penetrate to the center of the fiber leaving air pockets. Fig. 1C shows an even thicker fiber with a very large medulla and with very thin skin. This type of wool is called “Kemp”, is shed annually or more often, and corresponds to guard hair in fur-bearing animals.


2003 ◽  
Vol 34 (4) ◽  
pp. 219-226 ◽  
Author(s):  
Bart Duriez ◽  
Claudia Appel ◽  
Dirk Hutsebaut

Abstract: Recently, Duriez, Fontaine and Hutsebaut (2000) and Fontaine, Duriez, Luyten and Hutsebaut (2003) constructed the Post-Critical Belief Scale in order to measure the two religiosity dimensions along which Wulff (1991 , 1997 ) summarized the various possible approaches to religion: Exclusion vs. Inclusion of Transcendence and Literal vs. Symbolic. In the present article, the German version of this scale is presented. Results obtained in a heterogeneous German sample (N = 216) suggest that the internal structure of the German version fits the internal structure of the original Dutch version. Moreover, the observed relation between the Literal vs. Symbolic dimension and racism, which was in line with previous studies ( Duriez, in press ), supports the external validity of the German version.


2012 ◽  
Vol 28 (1) ◽  
pp. 25-31 ◽  
Author(s):  
Paula Elosua ◽  
Alicia López-Jáuregui

In this study the Eating Disorder Inventory-3 was adapted to Spanish and analyzed the internal psychometric properties of the test in a clinical sample of females with eating disorders. The results showed a high internal consistency of the scores as well as high temporal stability. The factor structure of the scale composites was analyzed using confirmatory factor analysis. The results supported the existence of a second-order structure beyond the psychological composites. The second-order factor showed high correlation with the factor related to eating disorders. Overall, the Spanish version of the EDI-3 showed good psychometric qualities in terms of internal consistency, temporal stability and internal structure.


Sign in / Sign up

Export Citation Format

Share Document