Dynamic Contour Tonometry and Goldmann Applanation Tonometry: Correlation with Intracameral Assessment of Intraocular Pressure

2011 ◽  
Vol 22 (1) ◽  
pp. 55-62 ◽  
Author(s):  
Ivano Riva ◽  
Luciano Quaranta ◽  
Andrea Russo ◽  
Andreas Katsanos ◽  
Eliana Rulli ◽  
...  

Purpose To compare intraocular pressure (IOP) measured using a dynamic contour tonometer (DCT) and a Goldmann applanation tonometer (GAT) with in vivo intracameral IOP, and establish the relationship between DCT, GAT and central corneal thickness (CCT) in patients with primary open-angle glaucoma (POAG). Materials and Methods We examined 50 eyes of 50 patients with POAG scheduled for glaucoma or cataract surgery. Immediately before surgery, CCT, GAT and DCT IOP were assessed, after which manometry of the anterior chamber was performed. A Bland-Altman plot was used to test the agreement among the 3 measurements of IOP, and univariate and multivariate regression analyses were used to evaluate the effect of CCT on DCT and GAT. Results On average, the DCT readings were 4.0±1.6 mmHg higher than the GAT readings and 2.3±2.4 mmHg higher than the manometric readings; the GAT measurements were generally a mean 1.7±1.8 mmHg lower than the manometric readings. The CCT had an almost similar influence on DCT and GAT measurements (p=0.84). Conclusions The DCT-measured IOP was significantly higher than that measured by means of GAT and anterior chamber manometry. The DCT and GAT readings were both influenced by CCT to the same extent.

Vision ◽  
2020 ◽  
Vol 4 (4) ◽  
pp. 45
Author(s):  
Marco Antonio de Castro Olyntho Junior ◽  
Lucas Bertazzi Augusto ◽  
Carolina P. B. Gracitelli ◽  
Andrew J. Tatham

Evaluate the effect of corneal thickness, densitometry and curvature on intraocular pressure (IOP) measurements obtained by Goldmann applanation tonometry (GAT), non-contact tonometry (NCT), rebound tonometry (RT), and dynamic contour tonometry (DCT). A cross-sectional prospective study involving 40 participants was performed. Corneal measurements were obtained using Pentacam (Oculus GMbH, Wetzlar, Germany), densitometry was measured at annuli of 0–2, 2–6, 6–10 and 10–12 mm. The relationship between corneal thickness (central, 4 and 6 mm), corneal astigmatism and corneal densitometry and IOP was examined. There was a significant relationship between corneal thickness (central, 4 and 6 mm) and GAT180, GAT90, RT, and NCT (P < 0.001 for all comparisons) but not for DCT. Higher corneal densitometry (6–10 mm and 10–12 mm zones) was associated with higher IOP from GAT180 and GAT90, and higher densitometry in the 6–10 mm zone correlated with higher IOP from NCT, however corneal densitometry increased with age. Accounting for age, the relationship between corneal densitometry and IOP measurements was not significant. In eyes with greater corneal astigmatism there was a greater difference between GAT90 and GAT180 measurements. IOP measurements may be affected by corneal thickness, densitometry and curvature. DCT was less affected by properties of the cornea compared to other devices.


2018 ◽  
Vol 12 (1) ◽  
pp. 314-321
Author(s):  
Cristina Sánchez-Barahona ◽  
Gema Bolívar ◽  
Dimitrios G. Mikropoulos ◽  
Anastasios G. Konstas ◽  
Miguel A. Teus

Objective: To evaluate in an in vivo rabbit model, the effect of topical timolol maleate therapy on the central corneal thickness response to acute intraocular pressure increases. Method: In this prospective and interventional controlled study, the central corneal thickness and intraocular pressure were measured in vivo in 12 rabbit eyes treated with topical timolol maleate for 1 month and in 12 controls at baseline, and after the intraocular pressure (measured by direct cannulation of the anterior chamber) was increased to 15 and 30 mmHg using a forced saline infusion into the anterior chamber. Results: There were no significant differences in the basal central corneal thickness values (control group, 373.2±12.9 µm; study group, 377.5±19.2 µm, p=0.5) or the central corneal thickness values when the intraocular pressure was increased to 15 mmHg (control group, 335.2±14.3 µm; study group, 330.0±32.1 µm, p=0.6) and to 30 mmHg (study group, 318.8±25.3 µm; control group, 329.8±21.0 µm, p=0.3). Conclusion: Rabbit corneas treated with topical timolol maleate for 1 month did not show a strain response to acute intraocular pressure increases that differed from control eyes. This is in contrast to a previous finding in which rabbit eyes treated with prostaglandin analogues had a greater decrease in central corneal thickness in response to a sudden intraocular pressure increase compared with untreated corneas.


2021 ◽  
Vol 62 (9) ◽  
pp. 1235-1242
Author(s):  
Gyeong Min Lee ◽  
Seung Joo Ha

Purpose: To compare the intraocular pressure reduction and changes in ocular pulse amplitude of travoprost 0.003% and tafluprost 0.0015%. Methods: We assessed patients who were diagnosed with open-angle glaucoma from January 2017 to July 2019 for the first time at our hospital. Forty-two eyes were assigned to the travoprost group (23 patients) and 26 eyes were assigned to the tafluprost group (14 patients). Changes in intraocular pressure were measured by Goldmann applanation tonometry (GAT), and corrected ocular pulse amplitude (cOPA) was measured using dynamic contour tonometry. Changes in these parameters were observed and compared for 1 year. Results: No significant differences were observed between the GAT measurements and the cOPA of patients treated with travoprost and tafluprost for 1 year (p = 0.512, p = 0.105). The change in initial intraocular pressure on GAT observed after 1 week was -5.32 ± 2.63 mmHg for travoprost and -3.79 ± 3.19 mmHg for tafluprost (p = 0.0457). The initial change in cOPA was +0.04 ± 0.9 mmHg in the travoprost group and -0.76 ± 0.97 mmHg in the tafluprost group (p = 0.0028). Conclusions: Travoprost and tafluprost reached the targeted intraocular pressure with no difference in the long-term effects of reduced intraocular pressure. However, travoprost was initially better at lowering intraocular pressure faster, and tafluprost had a greater effect on lowering OPA. Prostaglandin analogs can be selected individually by considering the aforementioned factors.


2019 ◽  
Vol 104 (4) ◽  
pp. 563-568 ◽  
Author(s):  
Masato Matsuura ◽  
Hiroshi Murata ◽  
Yuri Fujino ◽  
Mieko Yanagisawa ◽  
Yoshitaka Nakao ◽  
...  

AimsCorvis ST (CST) yields biomechanical corrected IOP (bIOP) which is purported to be less dependent on biomechanical properties. In our accompanied paper, it was suggested that the repeatability of bIOP is high. The purpose of the current study was to assess the relationship between intraocular pressure (IOP) measured with CST and central corneal thickness (CCT) and corneal hysteresis (CH), in comparison with IOP measured with Goldmann applanation tonometry (GAT) and the ocular response analyzer (ORA).MethodsA total of 141 eyes from 141 subjects (35 healthy eyes and 106 glaucomatous eyes) underwent IOP measurements with GAT, CST and ORA. The relationships between IOP measurements (ORA-IOPg, ORA-IOPcc, CST-bIOP and GAT IOP) and biomechanical properties (CCT, CH and corneal resistance factor (CRF)) were analysed using the linear regression analysis.ResultsIOPg, IOPcc and GAT IOP were significantly associated with CCT (p<0.001), whereas bIOP was not significantly associated with CCT (p=0.19). IOPg, bIOP and GAT IOP were significantly associated with CH (IOPg: p<0.001; bIOP: p<0.001; GAT IOP: p=0.0054), whereas IOPcc was not significantly associated with CH (p=0.18). All of IOP records were associated with CRF (p<0.001).ConclusionThe bIOP measurement from CST is independent from CCT, but dependent on CH and CRF.


2019 ◽  
Vol 104 (2) ◽  
pp. 276-281 ◽  
Author(s):  
Sang Yeop Lee ◽  
Eun Woo Kim ◽  
Wungrak Choi ◽  
Chan Keum Park ◽  
Sangah Kim ◽  
...  

AimsIn this study, we tested the hypothesis that intraocular pressure (IOP) parameters measured by dynamic contour tonometry (DCT) would be more relevant in progression of glaucoma when there is a history of laser refractive surgery (LRS) than the IOP parameters measured by Goldmann applanation tonometry (GAT) or calculated by correction formulae.MethodsNinety-eight eyes in 54 patients with open-angle glaucoma and a history of LRS were included in this retrospective study. IOP was measured by both GAT and DCT during follow-up. Baseline, mean, and peak IOP, IOP fluctuation, and IOP reduction were measured by each tonometry method. Corrected IOP parameters using central corneal thickness and mean keratometry values were also analysed. Clustered logistic regression was used to identify variables correlated with progression of glaucoma. Areas under the curve (AUCs) for correlated variables were also compared.ResultsThe mean DCT value (OR 1.36, p=0.024), peak DCT value (OR 1.19, p=0.02) and pattern SD (OR 1.10, p=0.016) were significant risk factors for progression. There was a significant difference in the predictive ability of the mean DCT and GAT values (AUC 0.63 and 0.514, respectively; p=0.01) and of the peak DCT and GAT values (0.646 and 0.503, respectively, p=0.009). The AUCs for corrected IOP did not exceed those of DCT.ConclusionsIOP measurements were more associated with progression of glaucoma when measurements were obtained by DCT than by GAT or correction formulae in eyes with a history of LRS.


2018 ◽  
Vol 102 (11) ◽  
pp. 1515-1519 ◽  
Author(s):  
Sung Uk Baek ◽  
Ahnul Ha ◽  
Young Kook Kim ◽  
Jin Wook Jeoung ◽  
Ki Ho Park

Background/aimsTo investigate the effect of eyelid manipulation on the measurement of intraocular pressure (IOP) using two different tonometries (rebound tonometry (RT) vs Goldmann applanation tonometry (GAT)).Methods103 patients with primary open-angle glaucoma were prospectively enrolled. For all of the patients, IOP measurements were performed in three different ways: (1) RT with lid manipulation (LM), (2) RT without LM and (3) GAT. The order of the three measurements was randomly selected. Additionally, the palpebral fissure height (PFH; elliptical space between upper and lower eyelids) was measured.ResultsThe mean value of IOP measured by GAT was 13.97±2.80 mm Hg, which was not significantly different from that by RT without LM (13.75±2.44 mm Hg; P=0.096), but which was significantly lower than that by RT with LM (15.21±2.91 mm Hg; P<0.001). On a Bland-Altman plot, RT with LM was overestimated relative to GAT (mean: −1.5) and RT without LM (mean: −1.2). Among the high IOPs (>20 mm Hg), interestingly, those measured by RT without LM were significantly lower than those measured by GAT (P<0.001). In the subgroup analysis of PFH, the smaller the PFH, the more exaggerated the IOP difference between GAT (P=0.014) and RT with LM (P<0.001).ConclusionRT-measured IOP was significantly exaggerated when manipulation was applied to the eyelid. This overall trend was more pronounced when PFH was small. GAT-measured IOP, meanwhile, showed a good correlation with IOP measured using RT without LM.


2019 ◽  
Vol 30 (3) ◽  
pp. 494-499 ◽  
Author(s):  
Dionysios D Pagoulatos ◽  
Zoi G Kapsala ◽  
Olga E Makri ◽  
Ilias G Georgalas ◽  
Constantinos D Georgakopoulos

Background: To compare intraocular pressure (IOP) measurements using Goldmann applanation tonometer (GAT) and air tonometer (non-contact tonometry [NT]) in vitrectomized eyes with high-viscosity silicone oil tamponade, as well as in normal eyes. Patients and Methods: In this prospective comparative study, 32 eyes with silicone oil tamponade of high viscosity (5700 CS) and 32 normal fellow eyes were included. IOP was measured by GAT and air tonometer 30 ± 12 days after vitrectomy, while measurements of central corneal thickness (CCT) were also obtained. Results: In eyes with silicone oil, IOP was 20.09 ± 4.91 mmHg and 16.75 ± 3.86 mmHg using contact tonometer and air tonometer, respectively ( p < 0.0001). In normal eyes, IOP was 16.41 ± 2.15 mmHg and 16.31 ± 2.49 mmHg using the same tonometry techniques and this difference was not statistically significant ( p = 0.598). In addition, no significant correlation was detected between IOP measurements using both techniques and age, gender, CCT, and type of lens. Conclusions: It seems that GAT overestimates IOP in eyes with high-viscosity silicone oil compared with NT, while both IOP measurement techniques in normal eyes provide similar values. Further assessment of available IOP measurement methods could possibly establish the most accurate technique for IOP estimation in vitrectomized eyes with silicone oil tamponade.


QJM ◽  
2021 ◽  
Vol 114 (Supplement_1) ◽  
Author(s):  
Fatma Gebreel Ahmed Gaber ◽  
Tamer Mohamed El- Raggal ◽  
Mohamed Gamil Metwally ◽  
Ahmed Abdelmonsef Ebeid

Abstract Background Measurement of intraocular pressure (IOP) plays a central role throughout ophthalmology. It is part of routine ophthalmologic examinations and important in the management and follow-up of patients with glaucoma. While elevated IOP remains the most important risk factor for development and progression of open angle glaucoma, at least half of the population diagnosed with open angle glaucoma is asymptomatic. Objectives The aim of our study is to compare the accuracy of intraocular pressure measurement before and after Laser in situ keratomeulsis (LASIK) surgery using three different types of Tonometers: Goldmann Applanation tonometry (GAT), Non contact tonometry (NCT) and Rebound tonometry (I care), considering the change in the central corneal thickness (CCT). Patients and Methods In this study Eighty eyes of 40 patients with mean age of 27.00±6.00 years were scheduled for LASIK..Central corneal thickness before and after surgery was obtained by Ultrasound (US) pachymetry.IOP values were measured before and after surgery using three different types of Tonometers: Goldmann Applanation tonometry, Non contact tonometry and Rebound tonometry. Results The results revealed that lower post-operative IOP measurements using all techniques. The least affected technique was Non –contact with IOP change 16%, followed by GAT with IOP change 18%, and finally Rebound with IOP change 19 %, respectively. The percentage of change in CCT between pre- and post- LASIK surgery measured with the Ultrasound pachymetry was statistically highly significant. There was a clinical significant correlation between Percentage of tissue ablation (PTA) and IOP change for GAT, NCT and rebound tonometry. Also, there was a significant correlation between Residual stromal bed (RSB) and IOP change for GAT and NCT. There was no clinical significant correlation between Ablation depth (AD) and percentage of change of IOP measurements pre and post LASIK, except for IOP measured with GAT when AD &lt; 40.00 µm. Conclusion Refractive surgery causes significant lowering of IOP as measured using Goldmann applanation tonometry, non contact tonometry and rebound tonometry. The least affected tonometry post LASIK is non contact tonometry. The reduction was correlated to the percentage of tissue ablated. The ideal method to measure IOP in post-LASIK patients would be a device that is free of corneal factors.


2020 ◽  
Vol 30 (6) ◽  
Author(s):  
Samuel Kyei ◽  
Frank Assiamah ◽  
Michael Agyemang Kwarteng ◽  
Cynthia Pakyennu Gboglu

BACKGROUND፡ The aim of this study was to determine whether Central Corneal Thickness (CCT) is associated with intraocular pressure measurement (IOP) with a Non-contact tonometer and the Goldmann applanation tonometer in glaucoma patients.MATERIALS AND METHODS: The study involved two hundred and thirty-two eyes of clinically diagnosed glaucoma patients receiving care at a referral facility. IOP measurements were obtained using both the Non-Contact Tonometer (NCT) and Goldmann Applanation Tonometer (GAT). The association between age, ethnicity, and CCT, as well as CCT on the measures of NCT and GAT, were analyzed.RESULTS: There were 64(55.2%) males and 52 (44.8%) females and their ages ranged from 18 to 85 years (mean age = 47.72; SD ±15.75 years). There was a weak positive correlation between the CCT and NCT findings in the right eye (r = 0.19, n = 116, p < 0.05) and in the left eye (r = 0.25, n = 116, p < 0.05). However, there was no correlation between CCT and GAT measurements. Age had a significant correlation with CCT while gender and ethnicity had no significant correlation.CONCLUSION: The study found a significant association between CCT and NCT. However, there was no significant association between CCT and GAT. CCT had an association with age but independent of gender and ethnicity since there was no significant relationship between these variables.