ANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF NEW UFLC METHOD FOR DETERMINATION OF QUERCETIN IN ALCOHOLIC AND AQUEOUS EXTRACTS OF CAMELLIA SINENSIS

INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (08) ◽  
pp. 22-29
Author(s):  
T. N Kumar ◽  
◽  
B Gurupadayya ◽  
K Mruthunjaya ◽  
K. V Sairam

A precise, simple, responsive and feasible ultra-fast liquid chromatography (UFLC) method for novel analysis of quercetin in aqueous and alcoholic extracts of Camellia sinensis with internal standard has been developed. The analysis was carried out on a Phenomenax-C18 column (250 × 4.6mm, 5μm). Here, acetonitrile and orthophosporic acid of 0.1% V/V in water at a 60:40 ratio was used as the mobile phase and propyl paraben was used as the internal standard. The linearity range of quercetin was found to be between 1-25 µg/mL and retention times of quercetin and propyl paraben were found to be 3.3 and 5.6 min, respectively. In this developed method, accuracy and recovery values of quercetin were found to be good, ranging from 100 to 102% respectively. The proposed current novel analytical method was validated with respect to system suitability, linearity, limit of detection (LOD), precision and limit of quantification (LOQ), accuracy (recovery), specificity and sensitivity in respect to the ICH guidelines. This proposed method can be readily used for determination of quercetin in research institutes and quality control laboratories.

2020 ◽  
Vol 10 (6) ◽  
pp. 49-56
Author(s):  
Sneha Jagnade ◽  
Pushpendra Soni ◽  
Lavakesh Kumar Omray

The aim of present study was to investigate the development and validation of a green analytical method for the determination of aspirin and domperidone. Method Development and Validation for Estimation of Domperidone and Aspirin in bulk or formulation by using RP-HPLC. The RP-HPLC method was developed for estimation of Aspirin and Domperidone in synthetic mixture by isocratically using 10 mM KH2PO4: Acetonitrile (20:80) as mobile phase, Prontosil C-18 column (4.6 x 250 mm, 5μparticle size) column as stationary phase and chromatogram was recorded at 231 nm. Then developed method was validated by using various parameters such as, linearity, Range accuracy, precision repeatability, intermediate precision, robustness, limit of detection, limit of quantification. The proposed methods were found to be linear with correlation coefficient close to one. Precision was determined by repeatability, Intermediate precision and reproducibility of the drugs. The robustness of developed method was checked by changing in the deliberate variation in solvent. The result obtained shows the developed methods to be Cost effective, Rapid (Short retention time), Simple, Accurate (the value of SD and % RSD less than 2), Precise and can be successfully employed in the routine analysis of these drugs in bulk drug as well as in tablet dosage form. The Simplicity, Rapidly and Reproducibility of the proposed method completely fulfill the objective of this research work. Keywords: Asprin; Domperidone; HPLC; Ultra Violet; Validation


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Indhu Priya Mabbu ◽  
G. Sumathi ◽  
N. Devanna

Abstract Background The aim of the present method is to develop and validate a specific, sensitive, precise, and accurate liquid chromatography-mass spectrometry (LC-MS) method for the estimation of the phenyl vinyl sulfone in the eletriptan hydrobromide. The effective separation of the phenyl vinyl sulfone was achieved by the Symmetry C18 (50 × 4.6 mm, 3.5 μm) column and a mobile phase composition of 0.1%v/v ammonia buffer to methanol (5:95 v/v), using 0.45 ml/min flow rate and 20 μl of injection volume, with methanol used as diluent. The phenyl vinyl sulfone was monitored on atomic pressure chemical ionization mode mass spectrometer with positive polarity mode. Results The retention time of phenyl vinyl sulfone was found at 2.13 min. The limit of detection (LOD) and limit of quantification (LOQ) were observed at 1.43 ppm and 4.77 ppm concentration respectively; the linear range was found in the concentration ranges from 4.77 to 27.00 ppm with regression coefficient of 0.9990 and accuracy in the range of 97.50–102.10%. The percentage relative standard deviation (% RSD) for six replicates said to be injections were less than 10%. Conclusion The proposed method was validated successfully as per ICH guidelines. Hence, this is employed for the determination of phenyl vinyl sulfone in the eletriptan hydrobromide.


Author(s):  
Murat Soyseven ◽  
Rüstem Keçili ◽  
Hassan Y Aboul-Enein ◽  
Göksel Arli

Abstract A novel analytical method, based on high-performance liquid chromatography with a UV (HPLC-UV) detection system for the sensitive detection of a genotoxic impurity (GTI) 5-amino-2-chloropyridine (5A2Cl) in a model active pharmaceutical ingredient (API) tenoxicam (TNX), has been developed and validated. The HPLC-UV method was used for the determination of GTI 5A2Cl in API TNX. The compounds were separated using a mobile phase composed of water (pH 3 adjusted with orthophosphoric acid): MeOH, (50:50: v/v) on a C18 column (150 × 4.6 mm i.d., 2.7 μm) at a flow rate of 0.7 mL min−1. Detection was carried out in the 254 nm wavelength. Column temperature was maintained at 40°C during the analyses and 10 μL volume was injected into the HPLC-UV system. The method was validated in the range of 1–40 μg mL−1. The obtained calibration curves for the GTI compound was found linear with equation, y = 40766x − 1125,6 (R2 = 0.999). The developed analytical method toward the target compounds was accurate, and the achieved limit of detection and limit of quantification values for the target compound 5A2Cl were 0.015 and 0.048 μg mL−1, respectively. The recovery values were calculated and found to be between 98.80 and 100.03%. The developed RP-HPLC-UV analytical method in this research is accurate, precise, rapid, simple and appropriate for the sensitive analysis of target GTI 5A2Cl in model API TNX.


2017 ◽  
Vol 20 (2) ◽  
pp. 241-249 ◽  
Author(s):  
A. Jasiecka-Mikołajczyk ◽  
J.J. Jaroszewski

Abstract Tigecycline (TIG), a novel glycylcycline antibiotic, plays an important role in the management of complicated skin and intra-abdominal infections. The available data lack any description of a method for determination of TIG in avian plasma. In our study, a selective, accurate and reversed-phase high performance liquid chromatography-tandem mass spectrometry method was developed for the determination of TIG in turkey plasma. Sample preparation was based on protein precipitation and liquid-liquid extraction using 1,2-dichloroethane. Chromatographic separation of TIG and minocycline (internal standard, IS) was achieved on an Atlantis T3 column (150 mm × 3.0 mm, 3.0 μm) using gradient elution. The selected reaction monitoring transitions were performed at 293.60 m/z → 257.10 m/z for TIG and 458.00 m/z → 441.20 m/z for IS. The developed method was validated in terms of specificity, selectivity, linearity, lowest limit of quantification, limit of detection, precision, accuracy, matrix effect, carry-over effect, extraction recovery and stability. All parameters of the method submitted to validation met the acceptance criteria. The assay was linear over the concentration range of 0.01-100 μg/ml. This validated method was successfully applied to a TIG pharmacokinetic study in turkey after intravenous and oral administration at a dose of 10 mg/kg at various time-points.


Author(s):  
DAVID ALEXANDER ◽  
Abdul Rohman

Objective: The aim of this research was to validate inductively coupled plasma-atomic emission spectroscopy (ICP-AES) for quantitative analysis of cadmium (Cd), chromium (Cr), cuprum (Cu), mangan (Mn) and nickel (Ni) in milk products. Methods: The heavy metals in milk were determined using ICP-AES at optimized wavelength. The method was validated by assessing several validation parameters which included linearity and range, accuracy, precision and sensitivity expressed by the limit of detection and limit of quantification. The validated method was then used for the analysis of milks commercially available. Results: ICP-AES for determination of Cd, Cr, Cu, Mn, and Ni was linear over a certain concentration range with a coefficient correlation value of>0.997. The limit of quantification values of Cd, Cr, Cu, Mn, and Ni were 0.0047; 0.0050; 0.0066; 0.0061; and 0.0169 µg/ml, respectively. The precision of analytical method exhibited relative standard deviation (RSD) values of 3.18%; 4.17%; 3.05%; 2.93%; and 4.47% during repeatability test and 5.28%; 5.06%; 3.67%; 3.67%; and 11.17% during intermediate precision of Cd, Cr, Cu, Mn, and Ni respectively. The recoveries of these metals assessed using standard addition method were 92.25; 90.88; 102.87; 94.50; and 86.85%, respectively. Conclusion: ICP-AES offered a reliable and fast method for the determination of heavy metals in milk products. The developed method could be proposed as an official method for determination of heavy metals in milk products.


2019 ◽  
Vol 57 (9) ◽  
pp. 769-777
Author(s):  
Nagaraju Rajana ◽  
Kaviaraj M Yarbagi ◽  
K Balakumaran ◽  
M V Madhubabu ◽  
J Mosesbabu ◽  
...  

Abstract Acetamide is a potential genotoxic impurity; it should control in drug substance based on daily dosage level. It forms from base-contaminated acetonitrile and by-product of some drug substances. The available methods for acetamide in drug substance and water samples were determined by GC-MS using internal standard with critical procedures. These developed and validated methods can assist in evaluating the reaction between acetonitrile and different bases and also determine trace level acetamide in drug substances. The method development was initiated with DB-624, 30 m, 0.32 width and 1.0-μm column. The column was used to validate at the 600 ppm TTC value. Similarly, the CP-SIL 5CB, 60 m, 0.32 width, the 5-μm column was used for the remaining TTC values. The validation study was performed for all TTC limits. The % RSD for precision at 600, 60, 20, 10 and 2.5 ppm was <15%. The % recovery at all TTC level was in between the 70 and 130%. Solution stability study was performed up to the 24 h. At 2.5 ppm, the results were <15% variation from the initial value. The linearities from the 50 to 150% concerning TTC values were more than limit of 0.98 correlation coefficient. The limit of detection and limit of quantitation values were 0.4 to the 1.3 ppm, respectively, for 2.5 ppm TTC limit method.


Author(s):  
Ayya Rajendra Prasad ◽  
Jayanthi Vijaya Ratna

 Objective: The objective of this study was developed and validated a novel, specific, precise, and simple ultraviolet (UV)-spectrophotometric method for the estimation of norfloxacin present in taste masked drug-resin complex.Methods: UV-spectrophotometric determination was performed with ELICO SL 1500 UV-visible spectrophotometer using 0.1 N HCl as a medium. The spectrum of the standard solution was run from 200 to 400 nm range for the determination of absorption maximum (λ max). λ max of norfloxacin was found at 278 nm. The absorbance of standard solutions of 1, 2, 3, 4, and 5 μg/ml of drug solution was measured at an absorption maximum at 278 nm against the blank. Then, a graph was plotted by taking concentration on X-axis and absorbance on Y-axis which gave a straight line. Validation parameters such as linearity and range, selectivity and specificity, limit of detection (LOD) and limit of quantification (LOQ), accuracy, precision, and robustness were evaluated as per the International Conference on Harmonization (ICH) guidelines.Results: Linearity for the UV-spectrophotometric method was noted over a concentration range of 1–5 μg/ml with a correlation coefficient of 0.9995. The LOD and LOQ for norfloxacin were found at 0.39 μg/ml and 1.19 μg/ml, respectively. Accuracy was in between 99.00% and 99.17%. % relative standard deviation for repeatability, intraday precision, and interday precision was found to be 0.600, in between 0.291 and 0.410, and in between 0.682 and 1.439, respectively. The proposed UV spectrophotometric method is found to be robust.Conclusion: The proposed UV-spectrophotometric method was validated according to the ICH guidelines, and results and statistical parameters demonstrated that the developed method is sensitive, precise, reliable, and simple for the estimation of norfloxacin present in taste masked drug-resin complex.


2018 ◽  
Vol 15 (1) ◽  
pp. 39-44 ◽  
Author(s):  
Feng Su ◽  
Zi-qing Sun ◽  
Xian-rui Liang

Introduction: Quantitative NMR spectroscopy (qNMR) is a rapid, simple and efficient method for the assay of sulfasalazine (SSZ) in commercial tablet formulation. Materials and Methods: The qNMR method was demonstrated using maleic acid as an internal standard and DMSO-d6 as a solvent. The characteristic signals of SSZ at δ 8.36 ppm and maleic acid at δ 6.28 ppm were quantified. The reliability of the quantification method had been implemented successfully in validated experiments including specificity and selectivity, linearity, recovery, precision concentration rang, limit of detection (LOD), limit of quantification (LOQ), stability and robustness. Conclusion: The method was found to be liner (R2 = 0.9991) from 8.62 to 20.14 mg/0.6 mL DMSO-d6 in the drug concentration range. The maximum relative standard deviation (RSD) of recovery and precision were tested to be 0.59% and 0.65%, respectively. The LOD and LOQ were determined to be 0.02, 0.07 mg/mL, respectively. The RSD of stability was 0.05%. The robustness was demonstrated by changing four different parameters with the maximum difference less than 0.9%. In addition, the result of qNMR showed in good agreement with the HPLC and UV methods. Based on the experiments, the developed method was successfully applied to the determination of SSZ in commercial tablet.


2019 ◽  
Vol 31 (1) ◽  
pp. 32-39
Author(s):  
Suman Shrivastava ◽  
Pooja Deshpande ◽  
S. J. Daharwal

Development of a method is crucial for discovery, development, and analysis of medicines in the pharmaceutical formulation. Method validation could also be thought to be one in all the foremost well-known areas in analytical chemistry as is reproduced within the substantial variety of articles submitted and presented in peer review journals every year. Validation of an analytical procedure is to demonstrate that it's appropriate for its intended purpose. Results from method validation are often wont to decide the quality, reliability and consistency of analytical results. Analytical methods need to be validated or revalidated. This review describes general approach towards validation process and validation parameters to be considered during validation of an analytical method. It also refers to various regulatory requirements like WHO, USFDA, EMEA, ICH, ISO/IEC. The parameters described here are according to ICH guidelines which include accuracy, precision, specificity, limit of detection, limit of quantification, linearity range and robustness.


Bioanalysis ◽  
2021 ◽  
Author(s):  
Sıdıka Ertürk Toker ◽  
Gamze Ergin Kızılçay ◽  
Olcay Sagirli

Aim: A new HPLC method with fluorescence detection has been developed and validated for the determination of levofloxacin, one of the fluoroquinolone class antibiotics, in breast milk. Materials & methods: Chromatographic separation was carried out on a reversed phase C18 column with acetonitrile and 10 mM o-phosphoric acid (25:75,v/v) mobile phase composition. Moxifloxacin was used as internal standard and the peaks were detected by fluorescence detection. Results & conclusion: Calibration graph was found linearly within the range of 2.5–500 ng/ml. Limit of detection and limit of quantification were found to be 0.63 and 2.11 ng/ml, respectively. Mean absolute recovery was 96.18%. The developed method has been successfully applied to the determination of levofloxacin in human breast milk taken from two healthy volunteers.


Sign in / Sign up

Export Citation Format

Share Document