Determination of Potential Genotoxic Impurity, 5-Amino-2-Chloropyridine, in Active Pharmaceutical Ingredient Using the HPLC-UV System

Author(s):  
Murat Soyseven ◽  
Rüstem Keçili ◽  
Hassan Y Aboul-Enein ◽  
Göksel Arli

Abstract A novel analytical method, based on high-performance liquid chromatography with a UV (HPLC-UV) detection system for the sensitive detection of a genotoxic impurity (GTI) 5-amino-2-chloropyridine (5A2Cl) in a model active pharmaceutical ingredient (API) tenoxicam (TNX), has been developed and validated. The HPLC-UV method was used for the determination of GTI 5A2Cl in API TNX. The compounds were separated using a mobile phase composed of water (pH 3 adjusted with orthophosphoric acid): MeOH, (50:50: v/v) on a C18 column (150 × 4.6 mm i.d., 2.7 μm) at a flow rate of 0.7 mL min−1. Detection was carried out in the 254 nm wavelength. Column temperature was maintained at 40°C during the analyses and 10 μL volume was injected into the HPLC-UV system. The method was validated in the range of 1–40 μg mL−1. The obtained calibration curves for the GTI compound was found linear with equation, y = 40766x − 1125,6 (R2 = 0.999). The developed analytical method toward the target compounds was accurate, and the achieved limit of detection and limit of quantification values for the target compound 5A2Cl were 0.015 and 0.048 μg mL−1, respectively. The recovery values were calculated and found to be between 98.80 and 100.03%. The developed RP-HPLC-UV analytical method in this research is accurate, precise, rapid, simple and appropriate for the sensitive analysis of target GTI 5A2Cl in model API TNX.

2019 ◽  
Vol 16 (1) ◽  
pp. 100-109
Author(s):  
Ibrahim Aljuffali ◽  
Fahad Almarri ◽  
A. F. M. Motiur Rahman ◽  
Fars Kaed Alanazi ◽  
Musaed Alkholief ◽  
...  

Background: The purpose of the current study was to develop a selective, precise, fast economical and advanced reverse phase ultra-high-performance liquid chromatography (UHPLC UV) method and validate it for the simultaneous estimation of cholecalciferol and its analogue 25- hydroxycholecalciferol in lipid-based self-nano emulsifying formulation (SNEDDS). Methods: The chromatographic separation was simply performed on a Dionex® UHPLC systems (Ultimate 3000, Thermo scientific) by using HSS C18 (2.1x50 mm, 1.8 µm) analytical column. The elution was carried out isocratically with the mobile phase consisting of acetonitrile and methanol in the ratio of 50:50 %v/v with a flow rate of 0.4 ml/min, followed by the UV detection at 265 nm. The injection volume was 1µl and the column temperature was maintained at 45°C. FDA regulatory guidelines were used to develop and validate the method. Results: The current developed UHPLC-UV method was found to be rapid (run time 2 min), and selective with the high resolution of cholecalciferol and 25-hydroxycholecalciferol (RT=0.530 min & 1.360 min) from different lipid matrices. The method was highly sensitive (Limit of Detection and Lower Limit of Quantification were 0.13 ppm & 0.51ppm, and 0.15 ppm & 0.54 ppm, respectively). The linearity, accuracy and precision were determined as suitable over the concentration range of 0.5-50.0 ppm for both the analytes. Conclusion: The proposed UHPLC-UV method can be used for the determination of cholecalciferol and 25-hydroxycholecalciferol in SNEDDS and marketed Vi-De 3® as pure forms (intact) with no interference of excipients or drug-related substances.


2012 ◽  
Vol 31 (1) ◽  
pp. 39 ◽  
Author(s):  
Lenče Velkoska-Markovska ◽  
Biljana Petanovska-Ilievska ◽  
Lila Vodeb

A fast, simple, precise and accurate reversed-phase high-performance liquid chromatography (RPHPLC)method with UV-DAD for simultaneous determination of desmedipham, phenmedipham and ethofumesate in the pesticide formulation “Inter OF” has been developed. The analysis was performed on a LiChrospher 60 RP-select B (25 cm × 0.4 cm, 5 μm, Merck) analytical column, with mobile phase of methanol/water (60/40, V/V), flow rate of 1 ml/min, UV-detection at 230 nm and constant column temperature at 25 ºC. The following parameters were determined for the developed method: retention factor, separation factor, limit of detection (LOD), limit of quantification (LOQ), precision of obtained results for peak area, linearity, recovery of analyte and active ingredients quantity in a pesticide formulation.


INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (10) ◽  
pp. 56-62
Author(s):  
A Anerao ◽  
◽  
V. Dighe ◽  
A Gupta ◽  
C. Patil ◽  
...  

N-Methylethanolamine is the side chain of the drug diphenhydramine hydrochloride. A sensitive high performance liquid chromatography method with pre-column derivatization was developed and validated for the determination of N-methylethanolamine impurity in diphenhydramine hydrochloride active pharmaceutical ingredient. HPLC method on column Cosmosil MS-II, C-18, 250 mm X 4.6 mm, particle size 5 μm with UV detector was used. The proposed method is specific, linear, accurate, rugged and precise. The calibration curves showed good linearity over the concentration range of 0.03 mg/g to 1.5 mg/g and the correlation coefficient was 0.999. Method had very low limit of detection (LOD) and limit of quantification (LOQ) as 0.01 mg/g and 0.03 mg/g, respectively, of the analyte. Accuracy was observed within 94.4% to 96.2%.


Author(s):  
Appasaheb Bajirao Lawande

ABSTRACT Objective:  The objective of the this work is to develop and validate a novel, simple,rapid and reliable analytical method for separation and determination of R-isomer impurity in Etodolac bulk drug material by normal-phase high-performance liquid chromatography as per International Conference on Harmonization guidelines. Methods: The Etodolac R- isomer and S-isomer were separated on a Chiralcel OD-H (150 x 4.0 mm, 5 micron) column by using Ethanol : n-Hexane:Trifluoroacetic acid (50:50:0.1 v/v.) mobile phase with equipped detector at wavelength 225 nm and 25 °C column oven temperature. The resolution between R-isomer and S-isomer were more than two recorded on chromatogram. The specified method was developed and validated for various parameters like reproducibility, limit of detection, limit of quantification, linearity and range, robustness, solution stability and mobile phase stability according to the International Conference on Harmonization (ICH) guidelines.  Results: Linearity were found for Etodolac R-isomer over the concentration range of 600–6000 ng/ml, with the linear regression (Correlation coefficient R = 0.998) and proved to be robust. Limit of detection and limit of quantification of Etodolac R-isomer was found to be 200 and 600 ng/ml. The retention time of R-isomer was considered to be 2.8 min. The percentage recovery of Etodolac R-isomer has been ranged from 97.0 to 102.0 in bulk drug material sample. The proposed analytical method has been found to be suitable, precise,reliable and accurate for the separation and quantitative determination of Etodolac R-isomer in bulk drug sample.                                                                                                                   Conclusion: A novel, speedy, accurate, precise, reliable and rugged analytical method has been developed and validated for normal phase high performance liquid chromatography to determine R-isomer impurity in Etodolac bulk drugs material as per ICH guideline. Keywords: Etodolac, HPLC, Known Impurity. Normal Phase, Validation.


Toxins ◽  
2019 ◽  
Vol 11 (2) ◽  
pp. 87 ◽  
Author(s):  
Wenbo Guo ◽  
Kai Fan ◽  
Dongxia Nie ◽  
Jiajia Meng ◽  
Qingwen Huang ◽  
...  

A simple and reliable analytical method for the simultaneous determination of alternariol (AOH), altenuene (ALT), tentoxin (TEN), altenusin (ALS), tenuazonic acid (TeA), and alternariol monomethyl ether (AME) in grapes was developed by ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS). A modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) procedure with the extraction by acetonitrile and purification by sodium chloride (0.5 g) and anhydrous magnesium sulfate (0.5 g) was established to recover the six Alternaria toxins. After validation by determining the linearity (R2 > 0.99), recovery (77.8–101.6%), sensitivity (limit of detection in the range of 0.03–0.21 μg kg−1, and limit of quantification in the range of 0.09–0.48 μg kg−1), and precision (relative standard deviation (RSD) ≤ 12.9%), the analytical method was successfully applied to reveal the contamination state of Alternaria toxins in grapes. Among 56 grape samples, 40 (incidence of 71.4%) were contaminated with Alternaria toxins. TEN was the most frequently found mycotoxin (37.5%), with a concentration range of 0.10–1.64 μg kg−1, followed by TeA (28.6%) and AOH (26.8%). ALT (10.7%), AME (3.6%), and ALS (5.4%) were also detected in some samples. To the best of our knowledge, this is the first report about the Alternaria toxins contamination in grapes in China.


Author(s):  
Kamran Ashraf ◽  
Syed Adnan Ali Shah ◽  
Mohd Mujeeb

<p><strong>Objective: </strong>A simple, sensitive, precise, and accurate stability indicating HPTLC (high-performance thin-layer chromatography) method for analysis of 10-gingerol in ginger has been developed and validated as perICH guidelines.</p><p><strong>Methods: </strong>The separation was achieved on TLC (thin layer chromatography) aluminum plates pre-coated with silica gel 60F<sub>254</sub> using n-hexane: ethyl acetate 55:45 (%, v/v) as a mobile phase. Densitometric analysis was performed at 569 nm.</p><p><strong>Results: </strong>This system was found to have a compact spot of 10-gingerol at <em>R</em><sub>F</sub> value of 0.57±0.03. For the proposed procedure, linearity (<em>r</em><sup>2</sup> = 0.998±0.02), limit of detection (18ng/spot), limit of quantification (42 ng/spot), recovery (ranging from 98.35%–100.68%), were found to be satisfactory.</p><p><strong>Conclusion: </strong>Statistical analysis reveals that the content of 10-gingerol in different geographical region varied significantly. The highest and lowest concentration of 10-gingerol in ginger was found to be present in a sample of Patna, Lucknow and Surat respectively which inferred that the variety of ginger found in Patna, Lucknow are much superior to other regions of India.</p>


INDIAN DRUGS ◽  
2020 ◽  
Vol 57 (05) ◽  
pp. 56-64
Author(s):  
Rani A Prameela ◽  
S. Madhavi ◽  
Rao B. Tirumaleswara ◽  
Sudheer Reddy CH.

A novel Ultra Performance Liquid Chromatography (UPLC) method was developed and validated for the simultaneous determination of antidiabetic drugs metformin hydrochloride and nateglinide. The method was developed using a Waters ACQUITY UPLC SB C18 (100 × 2.1 mm, 1.8 μm) column. The mobile phase consisting of 0.01 % potassium dihydrogen phosphate buffer (pH 5.8): acetonitrile (50: 50 V/V) was used throughout the analysis. The flow rate was 0.3 mL/min, the injection volume was 1.0 μL, column temperature was 30 0C, run time 3 min and detection was carried at 238 nm using a TUV detector. The retention times of metformin hydrochloride and nateglinide were found to be 1.28 1.71 min, respectively. Metformin hydrochloride and nateglinide were found to be linear over the concentration range of 125-750 and 15-90 μg/mL. The limit of detection and the limit of quantification for metformin hydrochloride were found to be 0.22 and 0.68 μg/mL, respectively, and, for nateglinide, 0.02 and 0.6 μg/mL, respectively. Developed method was validated as per ICH guidelines. The specificity of the method was confirmed by forced degradation study. The suggested method is suitable for determination of metformin hydrochloride and nateglinide in bulk and pharmaceutical dosage forms.


2017 ◽  
Vol 20 (2) ◽  
pp. 241-249 ◽  
Author(s):  
A. Jasiecka-Mikołajczyk ◽  
J.J. Jaroszewski

Abstract Tigecycline (TIG), a novel glycylcycline antibiotic, plays an important role in the management of complicated skin and intra-abdominal infections. The available data lack any description of a method for determination of TIG in avian plasma. In our study, a selective, accurate and reversed-phase high performance liquid chromatography-tandem mass spectrometry method was developed for the determination of TIG in turkey plasma. Sample preparation was based on protein precipitation and liquid-liquid extraction using 1,2-dichloroethane. Chromatographic separation of TIG and minocycline (internal standard, IS) was achieved on an Atlantis T3 column (150 mm × 3.0 mm, 3.0 μm) using gradient elution. The selected reaction monitoring transitions were performed at 293.60 m/z → 257.10 m/z for TIG and 458.00 m/z → 441.20 m/z for IS. The developed method was validated in terms of specificity, selectivity, linearity, lowest limit of quantification, limit of detection, precision, accuracy, matrix effect, carry-over effect, extraction recovery and stability. All parameters of the method submitted to validation met the acceptance criteria. The assay was linear over the concentration range of 0.01-100 μg/ml. This validated method was successfully applied to a TIG pharmacokinetic study in turkey after intravenous and oral administration at a dose of 10 mg/kg at various time-points.


2020 ◽  
Vol 11 (1) ◽  
pp. 985-992
Author(s):  
Hymavati Muppalla ◽  
Kiranmayi Peddi

The presence of pesticide residues in primary and derived agricultural products raises serious health concerns for consumers across the globe. The aim of the present study was to assess the level of pesticide residues in Okra in India. A multi-residue method for the quantification of fifty-four pesticides in okra is described in this work. The present study employed a modified quick, easy cheap, effective rugged and safe (QuEChERS) extraction procedure followed by UHPLC-MS/MS (Ultra-High-Performance Liquid Chromatography coupled to Tandem Mass Spectrometry) analysis. Validation of the method was according to the guidelines given by European Union SANCO/12571/2013. The levels of validation were 10.0, 50.0 and 100 µg kg-1. The following parameters such as linearity, the limit of detection (LOD) (nearer to 0.005 mg kg-1) and limit of quantification (LOQ) (nearer to 0.01 mg kg-1) were set to be acceptable. The trueness of the method for 54 pesticides in all Okra commodities was between 80-110% with satisfactory repeatability and within-run reproducibility except for the pesticide residues such as Thiamethoxam and Fenamidone. The measurement of uncertainty for each of the pesticide was below 50% and was estimated to be in the range of 5.37% - 10.71%, which meets the criteria established in the SANCO/12571/2013 document (European Union, 2013). This method is concluded to be applicable for the determination of pesticide residues in Okra.


2019 ◽  
Vol 32 (1) ◽  
pp. 69-72
Author(s):  
T. Naga Jhansi ◽  
D. Pavan Kumar ◽  
Nagaraju Rajana ◽  
D. Jayadeep Kumar ◽  
G. Nageswara Rao

A reverse phase chiral HPLC method was developed for the determination of (R)-2-aminobutanamide isomer content in (S)-2-amino-butanamide key starting material for levetiracetam drug substance by using a CROWNPAK CR (+) column. Perchloric acid solution (0.05 %) was used as mobile phase and the flow rate was finalized as 0.3 mL/min. UV detection wavelength was 200 nm and column temperature was set as 15 ºC. The limit of detection and limit of quantification were 0.0002 mg/mL and 0.0005 mg/mL, respectively. The linearity calibration curve of (R)-2-aminobutanamide was shown good from the range of 0.0005 mg/mL to 0.004 mg/mL. The recovery of (R)-2-aminobutanamide isomer was between the range of 93 to 106 % in presence of (S)-2-aminobutanamide. The method was validated and found to be precise, accurate and robust. The method can be used for determination of (R)-2-aminobutanamide in presence of (S)-2-aminobutanamide, which is the key intermediate for preparation of levetiracetam. This method was validated in as per ICH Q2 (R1) and USP validation of compendial methods (1225).


Sign in / Sign up

Export Citation Format

Share Document