scholarly journals Experimental Study on the Fire Resistance Performance of Prestressed Composite Beam with Corrugated Web under Standard Fire with Loading Condition

Author(s):  
Heung-Youl Kim ◽  
Hyung-Jun Kim ◽  
Kyung-Hoon Park ◽  
Bum-Yean Cho
2014 ◽  
Vol 14 (1) ◽  
pp. 35-41
Author(s):  
Bum-Yean Cho ◽  
Heung-Youl Kim ◽  
Hyung-Jun Kim ◽  
Hyun Kang ◽  
Kang-Su Kim

2014 ◽  
Vol 15 (4) ◽  
pp. 543-555 ◽  
Author(s):  
Deok Hee Won ◽  
Woo Sun Park ◽  
In-Sung Jang ◽  
Sang-Hun Han ◽  
Taek Hee Han

2014 ◽  
Vol 937 ◽  
pp. 424-427
Author(s):  
In Kyu Kwon

Fire resistance performance of structural members has been evaluated from each singular section and standard fire curve since the beginning of fire tests. However, the need of the exact fire resistance of H-section columns applied in the steel buildings has increased. The main reason for this is there is a difference between the conditions being conducted during the fire test and that from real situation. In this paper, the structural stability of H-section column made of an ordinary strength grade structural steels, SS 400, SM 400, and SM 490 at high temperature were evaluated and compared with boundary conditions and column’s length. This was done in order to suggest a new guideline for the application of fire protective materials in steel column in which the boundary conditions and column lengths are different from that tested with hinge to hinge and 3500 mm. The findings from this study showed hinge to hinge boundary condition was more conservative. And fire resistance performance of longer columns in the case of hinge to fixed and fixed to fixed boundary condition than from 3500 mm and hinge to hinge boundary condition can sustain at high temperature without adding fire protective materials.


2017 ◽  
Vol 737 ◽  
pp. 465-470
Author(s):  
Jae Hong An ◽  
In Hwan Yeo ◽  
Ki Soo Jeon ◽  
Ki Ho In

There are a lot of concerns on safety structure performance by being buildings to be large and high-rise. In particular, damage due to the fire recently leads to a large disaster and therefore a variety of countries operate the regulation on the fire resistance performance depending on the building structure. There are differences on the fire resistance design in each country but 50% of the design load is suggested to be reasonable for the normal temperature during the fire by applying the concept of the loading ratio to the fire resistance design of structures. Since the loading ratio is the factor having a major impact on the evaluation of the fire resistance performance, it should be preferentially considered. The study on setting up the loading ratio to evaluate the fire resistance performance and safety of structures has yet to be fully furnished in South Korea. Therefore, in this paper, the loading ratio proper for the construction status in South Korea is to be taken into account and then the ratio is to be proposed on the single reinforcement beam.


2014 ◽  
Vol 905 ◽  
pp. 268-272
Author(s):  
In Hwan Yeo ◽  
Bum Yean Cho ◽  
Jae Hong An ◽  
Byung Youl Min

Since the column members in buildings deal with both vertical and horizontal loads, appropriated amount of load should be estimated in order to evaluate the fire resistance performance of the columns under loaded condition. However, according to the ISO 834, the international standard for the evaluation of structural members, the fire resistance performance evaluation of column members is only based on the displacement and displacement rate under loaded condition in a standard fire. The purpose of this study is to suggest appropriate axial load ratios for the evaluation of fire resistance performance. The test conducted in this study produced appropriate axial load ratios for different slenderness ratios. They are expected to contribute to more accurate estimation of fire resistance performance and more efficient and cost-effective structural design.


2012 ◽  
Vol 193-194 ◽  
pp. 539-543
Author(s):  
Zhao Peng Ni ◽  
Pei Fang Qiu

Abstract : A series of standard fire-resistance tests were carried out to study the fire performance, failure modes and fire-resistance ratings of glulam beams. The test results showed that these glulam beams performed well during the tests, and the fire-resistance rating requirements can be achieved as expected. The study has provided necessary knowledge and experimental data for the determination of fire-resistance performance of glulam beams in the fire code of China.