scholarly journals Efficient Simulation of Airborne SAR Raw Data in Case of Motion Errors

2021 ◽  
Author(s):  
Yuhua Guo ◽  
Shichao Jin

In the simulation of SAR raw data, it is well-known that the frequency-domain algorithm is more efficient than a time-domain algorithm, making it is more suitable for extended scene simulation. However, the frequency-domain algorithm is perhaps better suited for ideal linear motion and requires some degrees of approximations to take the nonlinear motion effects. This chapter presents an efficient simulation approach based on hybrid time and frequency-domain algorithms under certain assumptions. The algorithm has high efficiency and is suitable for the simulation of extended scenes, which demands highly computational resources. The computational complexity of the proposed algorithm is analyzed, followed by numerical results to demonstrate the effectiveness and efficiency of the proposed approach.

Electronics ◽  
2019 ◽  
Vol 8 (3) ◽  
pp. 336 ◽  
Author(s):  
Yulei Qian ◽  
Daiyin Zhu

Synthetic Aperture Radar (SAR) raw data missing occurs when radar is interrupted by various influences. In order to cope with this problem, a new method is proposed to focus the azimuth missing SAR raw data via segmented recovery in this paper. A reference function in time domain is designed to make the missing raw data sparser in two dimensional frequency domain. Afterwards, greedy algorithms are available to recover the missing data in two dimensional frequency domain. In addition, in order to avoid range frequency aliasing problem caused by reference function multiplication in time domain, the missing raw data is split into several parts in range direction and is recovered with a segmented recovery strategy. Then, the recovered raw data is available to be focused with traditional SAR imaging algorithms. The range migration algorithm is chosen to deal with the recovered raw data in this paper. Point target and area target simulations are carried out to validate the effectiveness of the proposed method on azimuth missing SAR raw data. Moreover, the proposed method is implemented on real SAR data in order to further provide convincing demonstration.


2006 ◽  
Vol 44 (10) ◽  
pp. 2851-2860 ◽  
Author(s):  
G. Franceschetti ◽  
A. Iodice ◽  
S. Perna ◽  
D. Riccio

2018 ◽  
Vol 12 (7-8) ◽  
pp. 76-83
Author(s):  
E. V. KARSHAKOV ◽  
J. MOILANEN

Тhe advantage of combine processing of frequency domain and time domain data provided by the EQUATOR system is discussed. The heliborne complex has a towed transmitter, and, raised above it on the same cable a towed receiver. The excitation signal contains both pulsed and harmonic components. In fact, there are two independent transmitters operate in the system: one of them is a normal pulsed domain transmitter, with a half-sinusoidal pulse and a small "cut" on the falling edge, and the other one is a classical frequency domain transmitter at several specially selected frequencies. The received signal is first processed to a direct Fourier transform with high Q-factor detection at all significant frequencies. After that, in the spectral region, operations of converting the spectra of two sounding signals to a single spectrum of an ideal transmitter are performed. Than we do an inverse Fourier transform and return to the time domain. The detection of spectral components is done at a frequency band of several Hz, the receiver has the ability to perfectly suppress all sorts of extra-band noise. The detection bandwidth is several dozen times less the frequency interval between the harmonics, it turns out thatto achieve the same measurement quality of ground response without using out-of-band suppression you need several dozen times higher moment of airborne transmitting system. The data obtained from the model of a homogeneous half-space, a two-layered model, and a model of a horizontally layered medium is considered. A time-domain data makes it easier to detect a conductor in a relative insulator at greater depths. The data in the frequency domain gives more detailed information about subsurface. These conclusions are illustrated by the example of processing the survey data of the Republic of Rwanda in 2017. The simultaneous inversion of data in frequency domain and time domain can significantly improve the quality of interpretation.


2021 ◽  
Vol 9 (7) ◽  
pp. 781
Author(s):  
Shi He ◽  
Aijun Wang

The numerical procedures for dynamic analysis of mooring lines in the time domain and frequency domain were developed in this work. The lumped mass method was used to model the mooring lines. In the time domain dynamic analysis, the modified Euler method was used to solve the motion equation of mooring lines. The dynamic analyses of mooring lines under horizontal, vertical, and combined harmonic excitations were carried out. The cases of single-component and multicomponent mooring lines under these excitations were studied, respectively. The case considering the seabed contact was also included. The program was validated by comparing with the results from commercial software, Orcaflex. For the frequency domain dynamic analysis, an improved frame invariant stochastic linearization method was applied to the nonlinear hydrodynamic drag term. The cases of single-component and multicomponent mooring lines were studied. The comparison of results shows that frequency domain results agree well with nonlinear time domain results.


2021 ◽  
Vol 11 (5) ◽  
pp. 2410
Author(s):  
Nakisa Farrokhseresht ◽  
Arjen A. van der Meer ◽  
José Rueda Torres ◽  
Mart A. M. M. van der Meijden

The grid integration of renewable energy sources interfaced through power electronic converters is undergoing a significant acceleration to meet environmental and political targets. The rapid deployment of converters brings new challenges in ensuring robustness, transient stability, among others. In order to enhance transient stability, transmission system operators established network grid code requirements for converter-based generators to support the primary control task during faults. A critical factor in terms of implementing grid codes is the control strategy of the grid-side converters. Grid-forming converters are a promising solution which could perform properly in a weak-grid condition as well as in an islanded operation. In order to ensure grid code compliance, a wide range of transient stability studies is required. Time-domain simulations are common practice for that purpose. However, performing traditional monolithic time domain simulations (single solver, single domain) on a converter-dominated power system is a very complex and computationally intensive task. In this paper, a co-simulation approach using the mosaik framework is applied on a power system with grid-forming converters. A validation workflow is proposed to verify the co-simulation framework. The results of comprehensive simulation studies show a proof of concept for the applicability of this co-simulation approach to evaluate the transient stability of a dominant grid-forming converter-based power system.


Sign in / Sign up

Export Citation Format

Share Document