scholarly journals Diagnostic Value of Intraoperative Frozen Section in Breast-Conserving Surgery: A Systematic Review and Meta-analysis

2021 ◽  
Vol 14 (11) ◽  
Author(s):  
Gholamali Godazandeh ◽  
Reza Alizadeh-Navaei ◽  
Amir Shamshirian ◽  
Keyvan Heydari ◽  
Leyla Shojaee

Context: According to previous studies, using the frozen section procedure during breast surgery reduces the rate of error and the need for re-surgery. We aimed at performing a comprehensive systematic review and meta-analysis to provide reliable evidence on the diagnostic value of frozen section procedures in breast-conserving surgery (BCS). Data Sources: A thorough search was performed in PubMed, Embase, Cochrane Library, and Web of Science databases for human diagnostic studies that used the frozen section in BCS. Meta-analyses were done to find the sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), and negative likelihood ratio (NLR). Study Selection: Human diagnostic studies used the frozen section in breast-conserving surgery and studies that reported the sensitivity and specificity of the frozen section in BCS or contained data that could be calculated the desired parameters were selected for this meta-analysis. Data Extraction: Assessment of studies quality was done and data was extracted from included papers. Then, the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool was used to assess the quality of included papers. Results: Thirty-five papers were entered into our study. The meta-analysis indicated the high sensitivity (83.47, 95%CI 79.61 - 87.32) and specificity (99.29, 95%CI 98.89 - 99.68) for the frozen section in BCS, which resulted in an accuracy of 93.77 (95%CI 92.45 - 95.10). We also found a significant PPV (93.26, 95%CI 91.25 - 95.27), NPV (92.17, 95%CI 90.22 - 94.11), PLR (7.99, 95%CI 6.01 - 9.96), and NLR (0.18, 95%CI 0.14 - 0.23). Conclusions: The findings showed that intraoperative frozen section analysis has high sensitivity and specificity for evaluating lumpectomy margins in patients with early-stage breast cancer and significantly reduces the need for re-operation. Accordingly, re-operation costs are not imposed on the patient and reduce the anxiety of the patients.

Author(s):  
Zahra Hadizadeh-Talasaz ◽  
Ali Taghipour ◽  
Seyede Houra Mousavi-Vahed ◽  
Robab Latifnejad Roudsari

Background: For a woman with bleeding and threatened abortion, ultrasound scan is done to confirm the viability of the fetus; however, 10-15% of the embryos are eventually aborted. Distinguishing between women with good and poor prognosis can be a helpful approach. Objective: This study aimed to review the predictive value of Pregnancy-associated Plasma Protein A (PAPP-A) in relation to the diagnosis of fetal loss. Materials and Methods: The articles published in multiple databases including Web of Science, PubMed, MEDLINE, Scopus, and Persian databases such as ISC, Magiran, and IranMedx were searched for articles published until May 2019. MeSH terms was used for searching the databases including fetal loss OR pregnancy loss OR abortion OR miscarriage with the following word using AND; Pregnancy-Associated Plasma Protein- A OR PAPP-A. Two reviewers extracted data and recorded them in a pre-defined form and assessed the quality of articles using the Newcastle-Ottawa tool. Meta-analysis was done using the Comprehensive Meta-Analysis/2.0 software and MetaDisc. Results: A total number of 16 studies were eligible for the qualitative data synthesis, out of which 8 studies were included in the meta-analysis. All studies had high and medium quality. The forest plot analysis showed a sensitivity of 57% (95% CI: 53-63%), a specificity of 83% (95% CI: 80-85%), a positive likelihood ratio of 3.52 (95% CI: 2.44- 5.07), a negative likelihood ratio of 0.54 (95% CI: 0.37-0.79), and a diagnostic odds ratio of 6.95 (95% CI: 3.58-13.50). Conclusion: PAPP-A cannot be recommended on a routine basis for predicting fetal loss and still further research with a combination of other biomarkers is required. Key words: Pregnancy-associated plasma protein-A, Fetal loss, Pregnancy, Systematic review.


Sarcoma ◽  
2020 ◽  
Vol 2020 ◽  
pp. 1-6 ◽  
Author(s):  
Marc El Beaino ◽  
Daniel C. Jupiter ◽  
Tarek Assi ◽  
Elie Rassy ◽  
Alexander J. Lazar ◽  
...  

Background. Synovial sarcoma can present morphologically in multiple forms, including biphasic and monophasic subtypes. As a result, the histological diagnosis can sometimes be challenging. Transducin-Like Enhancer 1 (TLE1) is a transcriptional corepressor that normally is involved in embryogenesis and hematopoiesis but is also expressed in certain tumors. This systematic review examines the potential role of TLE1 as a diagnostic biomarker for the synovial sarcoma. Materials and Methods. A literature review and meta-analysis were conducted using the electronic databases Pubmed, the Cochrane Library, and Google Scholar. Thirteen studies met our eligibility criteria and were selected for in-depth analysis. Results. The mean sensitivity and specificity of TLE1 in detecting synovial sarcoma were 94% (95% CI 91%–97%) and 81% (95% CI 72%–91%), respectively, when all studies were aggregated together. The mean positive predictive value (PPV) of TLE1 was 75% (95% CI 62%–87%), whereas the negative predictive value (NPV) was 96% (95% CI 93%–98%). Conclusion. TLE1 is a sensitive and specific marker for synovial sarcoma that can aid in its diagnosis. Due to its involvement in several relevant signaling pathways, TLE1 might have direct relevance to the pathophysiology of the disease.


2022 ◽  
Vol 38 (3) ◽  
Author(s):  
Liping Lu ◽  
Xuming Pan

Non-contrast MRI is used for identifying patients with hepatocellular carcinoma (HCC), especially among high-risk patients with cirrhosis or chronic viral hepatitis. The accuracy of non-contrast MRI has been investigated with varying results. We performed this meta-analysis to consolidate the evidence on the accuracy of non-contrast MRI for the detection of HCC. We conducted a systematic search in the databases of PubMed Central, SCOPUS, MEDLINE, EMBASE and Cochrane from inception till November 2020. We used the STATA software “Midas” package for meta-analysis. We included 15 studies with 3,756 patients. The pooled sensitivity and specificity of non-contrast MRI for HCC detection were 84% (95%CI, 78%-88%) and 94% (95%CI, 91%-97%). The positive likelihood ratio was 14.9 (95% CI, 9.0-24.7) and the negative one 0.17 (0.12-0.23). The overall quality of the studies was high. We found significant heterogeneity based on chi-square test results and I2 statistic > 75%. Deek’s test showed the absence of publication bias. We found that non-contrast MRI has high sensitivity and specificity as a tool for detecting HCC. Studies exploring its accuracy in different ethnic populations are required to strengthen the evidence. doi: https://doi.org/10.12669/pjms.38.3.5142 How to cite this:Lu L, Pan X. Accuracy of Non-Contrast MRI for the Detection of Hepatocellular Carcinoma: A systematic review and meta-analysis. Pak J Med Sci. 2022;38(3):---------. doi: https://doi.org/10.12669/pjms.38.3.5142 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


2020 ◽  
Author(s):  
Amir Shamshirian ◽  
Amir Reza Aref ◽  
George W. Yip ◽  
Majid Ebrahimi Warkiani ◽  
Keyvan Heydari ◽  
...  

Abstract Background:Measurement of serum human epidermal growth factor receptor-2 (HER-2/neu) levels might play an essential role as a diagnostic/screening marker for the early selection of therapeutic approaches and predict prognosis in breast cancer patients. We aimed to undertake a systematic review and meta-analysis focusing on the diagnostic/screening value of serum HER-2 levels in comparison to routine methods.Methods:We performed a systematic search via PubMed, Scopus, Cochrane-Library, and Web of Science databases for human diagnostic studies reporting the levels of serum HER-2 in breast cancer patients, which was confirmed using the histopathological examination. Meta-analyses were carried out for sensitivity, specificity, accuracy, area under the ROC curve (AUC), positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), and negative likelihood ratio (NLR).Results:Fourteen studies entered into this investigation. The meta-analysis indicated the low sensitivity for serum HER2 levels (Sensitivity: 53.05, 95%CI 40.82-65.28), but reasonable specificity of 79.27 (95%CI 73.02-85.51), accuracy of 72.06 (95%CI 67.04-77.08) and AUC of 0.79 (95%CI 0.66-0.92). We also found a significant differences for PPV (PPV: 56.18, 95%CI 44.16-68.20), NPV (NPV: 76.93, 95%CI 69.56-84.31), PLR (PLR: 2.10, 95%CI 1.69-2.50) and NLR (NLR: 0.58, 95%CI 0.44-0.71).Conclusion:Our findings revealed that although serum HER-2 levels showed low sensitivity for breast cancer diagnosis, its specificity, accuracy and AUC were reasonable. Hence, it seems that the measurement of serum HER-2 levels can play a significant role as a verification test for initial negative screening test results, especially in low-income regions due to its cost-effectiveness and ease of implementation.


Author(s):  
Sneha Sethi ◽  
Xiangqun Ju ◽  
Richard M. Logan ◽  
Paul Sambrook ◽  
Robert A. McLaughlin ◽  
...  

Background: Advances in treatment approaches for patients with oral squamous cell carcinoma (OSCC) have been unsuccessful in preventing frequent recurrences and distant metastases, leading to a poor prognosis. Early detection and prevention enable an improved 5-year survival and better prognosis. Confocal Laser Endomicroscopy (CLE) is a non-invasive imaging instrument that could enable an earlier diagnosis and possibly help in reducing unnecessary invasive surgical procedures. Objective: To present an up to date systematic review and meta-analysis assessing the diagnostic accuracy of CLE in diagnosing OSCC. Materials and Methods. PubMed, Scopus, and Web of Science databases were explored up to 30 June 2021, to collect articles concerning the diagnosis of OSCC through CLE. Screening: data extraction and appraisal was done by two reviewers. The quality of the methodology followed by the studies included in this review was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. A random effects model was used for the meta-analysis. Results: Six studies were included, leading to a total number of 361 lesions in 213 patients. The pooled sensitivity and specificity were 95% (95% CI, 92–97%; I2 = 77.5%) and 93% (95% CI, 90–95%; I2 = 68.6%); the pooled positive likelihood ratios and negative likelihood ratios were 10.85 (95% CI, 5.4–21.7; I2 = 55.9%) and 0.08 (95% CI, 0.03–0.2; I2 = 83.5%); and the pooled diagnostic odds ratio was 174.45 (95% CI, 34.51–881.69; I2 = 73.6%). Although risk of bias and heterogeneity is observed, this study validates that CLE may have a noteworthy clinical influence on the diagnosis of OSCC, through its high sensitivity and specificity. Conclusions: This review indicates an exceptionally high sensitivity and specificity of CLE for diagnosing OSCC. Whilst it is a promising diagnostic instrument, the limited number of existing studies and potential risk of bias of included studies does not allow us to draw firm conclusions. A conclusive inference can be drawn when more studies, possibly with homogeneous methodological approach, are performed.


Author(s):  
Davi de Sá Cavalcante ◽  
Paulo Goberlânio de Barros Silva ◽  
Francisco Samuel Rodrigues Carvalho ◽  
Ana Rosa Pinto Quidute ◽  
Lúcio Mitsuo Kurita ◽  
...  

Objective: To summarize the evidence on the feasibility of maxillomandibular imaging exams-related fractal dimension (FD) in screening patients with osteoporosis. Methods: This registered systematic review followed the PRISMA-DTA statement. High sensitivity search strategies were developed for six primary databases and grey literature. QUADAS-2 items evaluated the risk of bias, and the GRADE approach assessed the evidence certainty. Results: From 1,034 records initially identified through database searching, four studies were included (total sample of 747 patients [osteoporosis, 136; control group, 611]). The meta-analysis showed that the overall sensitivity and specificity of the FD were 86.17 and 72.68%, respectively. In general, all studies showed low RoB and applicability concern. The certainty of the evidence was very low to moderate. Conclusions: This systematic review showed that the jaw-related FD presented sensitivity and specificity values higher than 70%, and its sensitivity in osteoporosis screening was a better parameter than specificity.


Author(s):  
Wang Yinzhong ◽  
Tian Xiaoxue ◽  
Tian Jinhui ◽  
Yang Pengcheng ◽  
Liu Xiaoying ◽  
...  

Background: Gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) has become a widely used liver-specific contrast agent worldwide, but its value and limitations as a diagnostic technique with hepatocellular carcinoma (HCC), have not been assessed. Introduction: A review of the latest evidence available on the diagnostic value of Gd-EOB-DTPA-enhanced MRI for the evaluation of HCC is reported. Methods: A systematic, comprehensive literature search was conducted with PubMed, Scopus, EMBASE, the Web of Science, the Cochrane Library, CNKI, vip, wanfangdata and CBM from inception to June 31, 2020. The QUADAS-2 tool was used to evaluate the quality of the included studies. Pooled sensitivity (SEN), pooled specificity (SPE), pooled positive likelihood ratio (PLR), pooled negative likelihood ratio (NLR), pooled diagnostic odds ratio (dOR) and summary receiver operating characteristic (SROC) curves were calculated to assess the diagnostic value of the individual diagnostic tests. Results: A total of 47 articles were included, involving a total of 6362 nodules in 37 studies based on per-lesion studies. There were 13 per-patient studies, including a total of 1816 patients. The results of the meta-analysis showed that the per-lesion studies pooled weighted values were SEN 0.90 [95% confidence interval (CI): 0.87-0.92], SPE 0.92 (95%CI: 0.90-0.94), PLR 11.6 (95%CI: 8.8-15.2), NLR 0.11 (95%CI: 0.09-0.14) and dOR 107.0 (95%CI: 74.0-155.0). The AUC of the SROC curve was 0.96. The per-patient studies pooled weighted values were SEN 0.84 [95% confidence interval (CI): 0.78-0.89], SPE 0.92 (95%CI: 0.88-0.94), PLR 10.4 (95%CI: 7.4-14.6), NLR 0.17 (95%CI: 0.12-0.24) and dOR 61.0 (95%CI: 42.0-87.0). The AUC of the SROC curve was 0.95 and subgroup analyses were performed. Conclusions: The diagnostic value of Gd-EOB-DTPA for HCC was quantitatively evaluated in a per-lesion study and a per-patient study using a systematic review of the literature. A positive conclusion was drawn: Gd-EOB-DTPA-enhanced imaging is a valuable diagnostic technique for HCC. The size of the nodules and the selection of the imaging diagnostic criteria may affect the diagnostic sensitivity.


2012 ◽  
Vol 22 (7) ◽  
pp. 1106-1112 ◽  
Author(s):  
Li Wu ◽  
Zhi-Yuan Dai ◽  
Yong-Hong Qian ◽  
Yan Shi ◽  
Feng-Ju Liu ◽  
...  

ObjectiveHuman epididymis protein 4 (HE4), a precursor of human epididymis protein, has been recently identified as a new promising serum biomarker for ovarian carcinoma. We performed a systematic review of studies that investigated the use of HE4 in the diagnosis of ovarian cancer in patients with pelvic or gynecological masses. We also evaluated the diagnostic performance of HE4 for differentiating between patients with benign gynecological disease and those with ovarian cancer.MethodsWe searched PubMed database (1990–2011) to collect articles in English that evaluated the diagnostic value of HE4 in patients with gynecological or pelvic masses. Two reviewers independently assessed the methodological quality of each study using the quality assessment of diagnostic accuracy studies tool. The data were analyzed using Meta-Disc1.4 software. Meta-analysis of the reported sensitivity and specificity of each study and summary receiver operating characteristic (SROC) curve were performed.ResultsA total of 9 studies involving 1807 women were included. When the control group was composed of healthy women, the pooled sensitivity and specificity for HE4 in diagnosing ovarian cancer were 83% (95% confidence interval [CI], 77%–88%) and 90% (95% CI, 87%–92%), respectively. The area under the SROC curve was 0.9271. When the control group was composed of women with benign disease, the pooled sensitivity and specificity for HE4 were 74% (95% CI, 69%–78%) and 90% (95% CI, 87%–92%). The area under the SROC curve was 0.8853.ConclusionThe current analysis indicated that HE4 may be a valuable marker in the diagnosis of ovarian carcinoma. Serum HE4 detection is not only a useful preoperative test for predicting the benign or malignant nature of pelvic masses but has a potential to be used as an initial step in ovarian cancer screening strategy.


2021 ◽  
Author(s):  
Yuan Chen ◽  
Faiza Naz ◽  
Shi Fu ◽  
Mengran Shi ◽  
Haihao Li ◽  
...  

Abstract Background: In recent years, qualitative and quantitative analysis of LncRNA has been reported as a potential method for early diagnosis of bladder cancer, but the results from each research are insufficient and not completely consistent. This meta-analysis aims to evaluate the diagnostic value of LncRNA for BC.Methods: We conducted a diagnostic meta-analysis and the diagnostic significance of LncRNA in blood, urine and tumor tissues was discussed. We searched the PUBMED, EMABASE, and Cochrane Library until June 2020. The current meta-analysis was performed using Review Manager 5.2, Stata 16.0 and Meta-Disc 1.4 software. Results: A total of 18 researches involving early and/or advanced bladder cancer were finally included. The overall diagnostic accuracy was measured as follows: pooled sensitivity and specificity were 0.72 (95%CI:0.70, 0.73) and 0.76 (95%CI: 0.75, 0.78). Pooled positive likelihood ratio and negative likelihood ratio were 3.09 (95%CI: 2.66, 3.58) and 0.37 (95%CI: 0.33, 0.42). Combined diagnostic odds ratio was 9.43 (95%CI: 7.30, 12.20). A high diagnostic accuracy was demonstrated by the summary receiver operating characteristic curve, with area under the curve of 0.82 (95%CI: 0.78, 0.85). UCA1 and H19 had the best diagnostic effect, their diagnostic sensitivity and specificity were 80%, 79% and 79%, 73% respectively, the combined diagnostic odds ratio was 16.85 and 12.67 respectively.Conclusions: This meta-analysis suggests that LncRNA have great potential in the diagnosis of bladder cancer, UCA1 and H19 had the best diagnostic effect. LncRNA panel is the future development direction in the diagnosis of bladder cancer. However, larger sample researches are needed to further confirm our conclusion.


Sign in / Sign up

Export Citation Format

Share Document