scholarly journals Bacteriological quality of drinking water from source to point of use among rural communities of Farta Woreda in North West, Ethiopia

2017 ◽  
Vol 11 (26) ◽  
pp. 1069-1074 ◽  
Author(s):  
Gedamu Kassie Genet ◽  
Haftu Hayelom Desta
2020 ◽  
Author(s):  
Shewayiref Geremew Gebremichael ◽  
Emebet Yismaw ◽  
Belete Dejen ◽  
Adeladilew Dires

AbstractBackgroundClean water is an essential element for human health, wellbeing, and prosperity. Every human being has the right to access safe drinking water. But, in now day, due to rapid population growth, illiteracy, lack of sustainable development, and climate change; it still faces a global challenge for about one billion people in the developing nation. The discontinuity of drinking water supply puts in force households either to use unsafe water storage materials or to use water from unimproved sources. This study aimed to identify the determinants of water source types, use, quality of water, and sanitation perception of physical parameters among urban households in North-West Ethiopia.MethodsA community-based cross-sectional study was conducted among households from February to March 2019. An interview-based pre-tested and structured questionnaire was used to collect the data. Data collection samples were selected randomly and proportional to each kebeles’ households. MS Excel and R Version 3.6.2 was used to enter and analyze the data; respectively. Descriptive statistics using frequencies and percentages were used to explain the sample data concerning the predictor variable. Both bivariate and multivariate logistic regressions were used to assess the association between the independent and the response variables.ResultsFour hundred eighteen (418) households have participated. Based on the study undertaken, 78.95% of households used improved and 21.05% of households used unimproved drinking water sources. Households drinking water sources are significantly associated with age of participant (x2 = 20.392, df=3), educational status (x2 = 19.358, df=4), source of income (x2 = 21.777, df=3), monthly income (x2 = 13.322, df=3), availability of additional facilities (x2 = 98.144, df=7), cleanness status (x2 =42.979, df=4), scarcity of water (x2 = 5.1388, df=1) and family size (x2 = 9.934, df=2). The logistic regression analysis also indicated as those factors are significantly determined (p 0.05) the water source types used by households. Factors such as availability of toilet facility, household member type, and sex of head of the household are not significantly associated with the drinking water sources.ConclusionThe study showed that being an older age group of the head of the household, being government employer, merchant and self-employed, being a higher income group, the presence of all facilities in the area, lived in a clean surrounding and lower family size are the determinant factors of using drinking water from improved sources. Therefore; the local, regional, and national governments and other supporting organizations shall improve the accessibility and adequacy of drinking water from improved sources through short and long time plans for the well-being of the community in the area.


2013 ◽  
Vol 7 (1) ◽  
pp. 96 ◽  
Author(s):  
F Ayoade ◽  
SO Fayemi ◽  
GG Daramola ◽  
A Osho ◽  
NE Oyejide ◽  
...  

2017 ◽  
Vol 11 ◽  
pp. 117863021773553 ◽  
Author(s):  
Joab Odhiambo Okullo ◽  
Wilkister Nyaora Moturi ◽  
George Morara Ogendi

2015 ◽  
Vol 10 (53) ◽  
pp. 4844-4849 ◽  
Author(s):  
Benmerine BENGARNIA ◽  
Miloud HADADJI ◽  
Mohammed RAMDANI ◽  
Mebrouk KIHAL

2015 ◽  
Vol 9 (08) ◽  
pp. 844-848 ◽  
Author(s):  
Sita Malhotra ◽  
Shailpreet K Sidhu ◽  
Pushpa Devi

Introduction: Safe water is a precondition for health and development and is a basic human right, yet it is still denied to hundreds of millions of people throughout the developing world. Water-related diseases caused by insufficient safe water supplies, coupled with poor sanitation and hygiene, cause 3.4 million deaths a year, mostly in children. Methodology: The present study was conducted on 1,317 drinking water samples from various water sources in Amritsar district in northern India. All the samples were analyzed to assess bacteriological quality of water for presumptive coliform count by the multiple tube test. Results: A total of 42.9% (565/1,317) samples from various sources were found to be unfit for human consumption. Of the total 565 unsatisfactory samples, 253 were from submersible pumps, 197 were from taps of piped supply (domestic/public), 79 were from hand pumps, and 36 were from various other sources A significantly high level of contamination was observed in samples collected from submersible pumps (47.6%) and water tanks (47.3%), as these sources of water are more exposed and liable to contamination. Conclusions: Despite continuous efforts by the government, civil society, and the international community, over a billion people still do not have access to improved water resources. Bacteriological assessment of all sources of drinking should be planned and conducted on regular basis to prevent waterborne dissemination of diseases.


2017 ◽  
Vol 13 (3) ◽  
Author(s):  
Suhadi Prayitno

Cases, concerns and complaints in public about refill drinking water,  low businessmen DAMIU are checked routinely product processed as well as the mandate of the Consumer Protection Act, Kepmerindag RI and Permenkes RI on monitoring refill drinking water background for the author to conduct research. Purpose to describe the bacteriological quality of refill drinking water in terms of disinfection method used in District Ngawi. This method is descriptive study and cluster sampling to 49 samples DAMIU in District Ngawi with the results of the method used, namely ultraviolet disinfection, ozonation and reverse  osmosis. The results bacteriological quality (total coliforms) of any disinfection method shows a different picture, which shows the method of disinfection reverse osmosis bacteriological quality with the percentage of 50.00%, followed by ozonation method of 46.15% and the latter by the ultraviolet method percentage value 44.12 %. The ability of any reduction in total coliform disinfection method shows a different picture, in which the reverse osmosis method of disinfection showed total coliform reduction percentage of 94.08%, followed by ozonation method of 91.46% and the latter by the ultraviolet method percentage value 86.09%. The conclusion willingness, support and cooperation of all stakeholders is needed to improve the supervision, guidance and inspection of the quality of refill drinking water in Ngawi. Key word : water, disinfection, coliform


Sign in / Sign up

Export Citation Format

Share Document