scholarly journals Effect of different ergonomic supports on muscle activity of dentists during posterior composite restoration

PeerJ ◽  
2019 ◽  
Vol 7 ◽  
pp. e8028
Author(s):  
Manuel López-Nicolás ◽  
José A. García-Vidal ◽  
Francesc Medina-Mirapeix ◽  
Joaquín P. Sánchez-Onteniente ◽  
Juan D. Berná Mestre ◽  
...  

Background The aim of this study was to evaluate the effect of different ergonomic supports on the muscle activity of two trunk muscles while a group of dentists performed a common dental procedure on a phantom head, divided into three tasks. Methods A one-way repeated measures study (ANOVA) was conducted on a group of 36 dentists. The middle trapezius and lumbar erector spinae muscles were measured with and without the use of different ergonomic supports (ergonomic stool, magnification lenses and both) using a portable surface electromyography (sEMG) device. Intraclass correlation coefficients (ICCs) and the absolute standard error of measurement (SEM) were used to establish the reliability of the baseline measures without ergonomic supports. Results The sEMG showed excellent ICCs (ranging from 0.92 to 0.99) and SEM. Bonferroni post hoc tests showed differences between the three ergonomic supports (p < 0.001) in both muscles studied. The lowest muscle activity measurement occurred with the isolated used of magnification lenses. The use of the ergonomic stool increased the muscle activity of the middle trapezius and lumbar erector spinae muscles to a greater extent than the magnification lenses. The combination of the ergonomic stool and the magnification lenses produced a different effect on each muscle.

2012 ◽  
Vol 102 (2) ◽  
pp. 130-138 ◽  
Author(s):  
Jeanna M. Fascione ◽  
Ryan T. Crews ◽  
James S. Wrobel

Background: Identifying the variability of footprint measurement collection techniques and the reliability of footprint measurements would assist with appropriate clinical foot posture appraisal. We sought to identify relationships between these measures in a healthy population. Methods: On 30 healthy participants, midgait dynamic footprint measurements were collected using an ink mat, paper pedography, and electronic pedography. The footprints were then digitized, and the following footprint indices were calculated with photo digital planimetry software: footprint index, arch index, truncated arch index, Chippaux-Smirak Index, and Staheli Index. Differences between techniques were identified with repeated-measures analysis of variance with post hoc test of Scheffe. In addition, to assess practical similarities between the different methods, intraclass correlation coefficients (ICCs) were calculated. To assess intrarater reliability, footprint indices were calculated twice on 10 randomly selected ink mat footprint measurements, and the ICC was calculated. Results: Dynamic footprint measurements collected with an ink mat significantly differed from those collected with paper pedography (ICC, 0.85–0.96) and electronic pedography (ICC, 0.29–0.79), regardless of the practical similarities noted with ICC values (P = .00). Intrarater reliability for dynamic ink mat footprint measurements was high for the footprint index, arch index, truncated arch index, Chippaux-Smirak Index, and Staheli Index (ICC, 0.74–0.99). Conclusions: Footprint measurements collected with various techniques demonstrate differences. Interchangeable use of exact values without adjustment is not advised. Intrarater reliability of a single method (ink mat) was found to be high. (J Am Podiatr Med Assoc 102(2): 130–138, 2012)


Sports ◽  
2019 ◽  
Vol 7 (5) ◽  
pp. 125
Author(s):  
Adam M. Gonzalez ◽  
Gerald T. Mangine ◽  
Robert W. Spitz ◽  
Jamie J. Ghigiarelli ◽  
Katie M. Sell

To determine the agreement between the Open Barbell (OB) and Tendo weightlifting analyzer (TWA) for measuring barbell velocity, eleven men (19.4 ± 1.0 y) performed one set of 2–3 repetitions at four sub-maximal percentage loads, [i.e., 30, 50, 70, and 90% one-repetition maximum (1RM)] in the back (BS) and front squat (FS) exercises. During each repetition, peak and mean barbell velocity were recorded by OB and TWA devices, and the average of the 2–3 repetitions was used for analyses. Although the repeated measures analysis of variance revealed significantly (p ≤ 0.005) greater peak and mean velocity scores from OB across all intensities, high intraclass correlation coefficients (ICC2,K = 0.790–0.998), low standard error of measurement (SEM2,K = 0.040–0.119 m·s−1), and coefficients of variation (CV = 2–4%) suggested consistency between devices. Positive (r = 0.491–0.949) Pearson correlations between averages and differences (between devices) in peak velocity, as well as associated Bland-Altman plots, showed greater differences occurred as the velocity increased, particularly at low-moderate intensity loads. OB consistently provides greater barbell velocity scores compared to TWA, and the differences between devices were more apparent as the peak velocity increased with low-to-moderate loads. Strength coaches and athletes may find better agreement between devices if the mean velocity scores are only considered.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Pieter-Jan Verhelst ◽  
H. Matthews ◽  
L. Verstraete ◽  
F. Van der Cruyssen ◽  
D. Mulier ◽  
...  

AbstractAutomatic craniomaxillofacial (CMF) three dimensional (3D) dense phenotyping promises quantification of the complete CMF shape compared to the limiting use of sparse landmarks in classical phenotyping. This study assesses the accuracy and reliability of this new approach on the human mandible. Classic and automatic phenotyping techniques were applied on 30 unaltered and 20 operated human mandibles. Seven observers indicated 26 anatomical landmarks on each mandible three times. All mandibles were subjected to three rounds of automatic phenotyping using Meshmonk. The toolbox performed non-rigid surface registration of a template mandibular mesh consisting of 17,415 quasi landmarks on each target mandible and the quasi landmarks corresponding to the 26 anatomical locations of interest were identified. Repeated-measures reliability was assessed using root mean square (RMS) distances of repeated landmark indications to their centroid. Automatic phenotyping showed very low RMS distances confirming excellent repeated-measures reliability. The average Euclidean distance between manual and corresponding automatic landmarks was 1.40 mm for the unaltered and 1.76 mm for the operated sample. Centroid sizes from the automatic and manual shape configurations were highly similar with intraclass correlation coefficients (ICC) of > 0.99. Reproducibility coefficients for centroid size were < 2 mm, accounting for < 1% of the total variability of the centroid size of the mandibles in this sample. ICC’s for the multivariate set of 325 interlandmark distances were all > 0.90 indicating again high similarity between shapes quantified by classic or automatic phenotyping. Combined, these findings established high accuracy and repeated-measures reliability of the automatic approach. 3D dense CMF phenotyping of the human mandible using the Meshmonk toolbox introduces a novel improvement in quantifying CMF shape.


2003 ◽  
Vol 83 (10) ◽  
pp. 899-906 ◽  
Author(s):  
Deborah Falla ◽  
Gwendolen Jull ◽  
Paul Dall'Alba ◽  
Alberto Rainoldi ◽  
Roberto Merletti

Abstract Background and Purpose. This study evaluated an electromyographic technique for the measurement of muscle activity of the deep cervical flexor (DCF) muscles. Electromyographic signals were detected from the DCF, sternocleidomastoid (SCM), and anterior scalene (AS) muscles during performance of the craniocervical flexion (CCF) test, which involves performing 5 stages of increasing craniocervical flexion range of motion—the anatomical action of the DCF muscles. Subjects. Ten volunteers without known pathology or impairment participated in this study. Methods. Root-mean-square (RMS) values were calculated for the DCF, SCM, and AS muscles during performance of the CCF test. Myoelectric signals were recorded from the DCF muscles using bipolar electrodes placed over the posterior oropharyngeal wall. Reliability estimates of normalized RMS values were obtained by evaluating intraclass correlation coefficients and the normalized standard error of the mean (SEM). Results. A linear relationship was evident between the amplitude of DCF muscle activity and the incremental stages of the CCF test (F=239.04, df=36, P&lt;.0001). Normalized SEMs in the range 6.7% to 10.3% were obtained for the normalized RMS values for the DCF muscles, providing evidence of reliability for these variables. Discussion and Conclusion. This approach for obtaining a direct measure of the DCF muscles, which differs from those previously used, may be useful for the examination of these muscles in future electromyographic applications.


Author(s):  
Richard R. Suminski ◽  
Gregory M. Dominick ◽  
Matthew Saponaro

Evidence suggests that video captured with a wearable video device (WVD) may augment or supplant traditional methods for assessing park use. Unmanned aerial systems (UASs) are used to assess human activity, but research employing them for park assessments is sparse. Therefore, this study compared park user counts between a WVD and UAS. A diverse set of 33 amenities (e.g., playground) in three parks were videoed simultaneously by one researcher wearing a WVD and another operating the UAS. Assessments were done at 12 p.m. and 7 p.m. on weekends, with one park evaluated on two occasions 7 days apart. Two investigators independently reviewed videos and reached consensus on the counts of individuals at each amenity. Intraclass correlation coefficients (ICCs) were used to determine intra- and interrater reliabilities. A total of 404 (M = 4.7; SD = 9.6) and 389 (M = 4.5; SD = 9.0) individuals were counted in the UAS and WVD videos, respectively. Absolute agreement was 86% (74/86) and 100% when no individuals were using the amenity. Whether using all 86 videos or only videos having people (48 videos), ICCs indicated excellent reliability (ICC = .99; p < .001). The totals seen for the repeated measures were UAS = 146 and WVD = 136 for Day 1 and UAS = 169 and WVD = 161 for Day 2. Intrarater reliability was excellent for the UAS (ICC = .92; p < .001) and good for the WVD (ICC = .89; p < .001). Disagreement was mainly due to obstructions—people behind or under structures. This study provides support for the use of UASs for counting park users and future research examining the potential benefits of video analysis for assessing park use.


2018 ◽  
Vol 63 (4) ◽  
pp. 453-460 ◽  
Author(s):  
Vahid Abdollah ◽  
Eric C. Parent ◽  
Michele C. Battié

Abstract Degenerated discs have shorter T2-relaxation time and lower MR signal. The location of the signal-intensity-weighted-centroid reflects the water distribution within a region-of-interest (ROI). This study compared the reliability of the location of the signal-intensity-weighted-centroid to mean signal intensity and area measurements. L4-L5 and L5-S1 discs were measured on 43 mid-sagittal T2-weighted 3T MRI images in adults with back pain. One rater analysed images twice and another once, blinded to measurements. Discs were semi-automatically segmented into a whole disc, nucleus, anterior and posterior annulus. The coordinates of the signal-intensity-weighted-centroid for all regions demonstrated excellent intraclass-correlation-coefficients for intra- (0.99–1.00) and inter-rater reliability (0.97–1.00). The standard error of measurement for the Y-coordinates of the signal-intensity-weighted-centroid for all ROIs were 0 at both levels and 0 to 2.7 mm for X-coordinates. The mean signal intensity and area for the whole disc and nucleus presented excellent intra-rater reliability with intraclass-correlation-coefficients from 0.93 to 1.00, and 0.92 to 1.00 for inter-rater reliability. The mean signal intensity and area had lower reliability for annulus ROIs, with intra-rater intraclass-correlation-coefficient from 0.5 to 0.76 and inter-rater from 0.33 to 0.58. The location of the signal-intensity-weighted-centroid is a reliable biomarker for investigating the effects of disc interventions.


2006 ◽  
Vol 3 (s2) ◽  
pp. S67-S77 ◽  
Author(s):  
Michelle Ihmels ◽  
Gregory J. Welk ◽  
James J. McClain ◽  
Jodee Schaben

Background:Advances in BIA offer practical alternative approaches to assessing body composition in young adolescents and have not been studied for comparability.Methods:This study compared reliability and convergent validity of three field tests (2-site skinfold, Omron and Tanita BIA devices) on young adolescents. Reliability was determined using intraclass correlation coefficients, convergent validity was examined by computing correlations among the three estimates, differences in estimated body fat values were evaluated using repeated-measures ANOVA, and classification agreement was computed for achieving FITNESSGRAM® Healthy Fitness Zone.Results:ICC values of all three measures exceeded .97. Correlations ranged from .74 to .81 for males and .79 to .91 for females. Classification agreement values ranged from 82.8% to 92.6%.Conclusions:Results suggest general agreement among the selected methods of body composition assessments in both boys and girls with the exception that percent body fat in boys by Tanita BIA is significantly lower than skinfold estimation.


Author(s):  
Megan Sax van der Weyden ◽  
Christopher D. Black ◽  
Daniel Larson ◽  
Brian Rollberg ◽  
Jason A. Campbell

This investigation examined relationships between a Special Weapons and Tactics-specific fitness test (SORT) and an obstacle course (OC) used for qualification in fourteen male SWAT members from three local, regional police departments. The SORT included: squat, pushup, and lunge in 60 s; pullup hold; sled drag; and Yo-Yo Intermittent Recovery Test L1. The obstacle course included: 25 m sprint (repeated); window ascent; scale under a wall; 25 m serpentine run (repeated), body drag (20 m, repeated). Pearson coefficients examined SORT and OC relationships (p ≤ 0.05); intraclass correlation coefficients (ICC2,1) assessed agreement of SORT trials. Repeated measures ANOVA evaluated differences in SORT metrics across time. Coefficients of variation (COV) examined SORT scoring consistency. The YoYo test was related to all SORT assessments (r = −0.803–0.894), except sled drag. The remaining SORT metrics were related to ≥two tests. SORT COVs ranged from 0.77–13.26% for trials 1–2 but decreased between trials 2–3 (0.95–8.97%). The OC was associated with YoYo, lunges, squats and sled drag (r = −0.790, −0.730, −0.766, and 0.802, respectively). No differences (p > 0.05) existed across SORT trials for event scores. The SORT battery appears to be a valid and reliable testing measure to assess SWAT occupational specific fitness.


Biomechanics ◽  
2020 ◽  
Vol 1 (1) ◽  
pp. 1-14
Author(s):  
Callum Stratford ◽  
Thomas Dos’Santos ◽  
John J. McMahon

The purpose of this study was to identify whether ten repetitions and three trials were necessary to achieve stability in peak reactive strength index (RSI) during the 10/5 repeated jumps test (RJT). Twenty-five males, from multiple sports, performed three trials of the RJT on an in-ground force plate, with 90 seconds’ rest between trials. Intraclass correlation coefficients (ICC = 0.916–0.986) and coefficients of variation (CV ≤ 14.5%) were considered acceptable for all variables. Repeated-measures analysis of variance and Freidman’s tests revealed large and significant differences (p ≤ 0.006, η2 = 0.159–0.434, power ≥ 0.859) in ground contact time (GCT), jump height (JH), and subsequently RSI both between trials and repetitions. Pairwise comparisons revealed that repetitions 1–3 produced longer GCTs (p ≤ 0.05, d = 0.41–1.40), lower JHs (p ≤ 0.05, d = 0.31–0.56), and lower RSI values (p ≤ 0.05, d = 0.35–1.24). The shortest GCTs, greatest JHs and greater RSIs occurred between repetitions 7 and 10, with approximately 60% of peak RSIs occurring during these ranges. The sequential estimate technique revealed that seven repetitions were needed to attain stability in mean peak RSI. Non-significant (p = 0.554) and negligible differences (d ≤ 0.09) in the five best RSIs between trials were noted. One trial of the 10/5 RJT is sufficient to evaluate peak RSI in athletes and should reduce data collection time and fatigue.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jennifer H. Therkorn ◽  
Daniella R. Toto ◽  
Michael J. Falvo

AbstractAlternative methods have been proposed to report spirometry indices from test sessions (forced expiratory volume 1 s, FEV1; forced vital capacity, FVC). However, most use the American and European Societies’ standard (ATS/ERS) which stops sessions once a repeatability threshold is met which may not accurately represent intra-session variability. Our goal was to repeat trials beyond the repeatability threshold and evaluate alternative reporting methods. 130 adults performed spirometry across two visits. Spirometry indices were reported using the ATS/ERS standard and four alternatives. 78 participants (60%) had valid data for all methods and visits. Intra-session coefficients of variation were low (FEV1: 3.1–3.7%; FVC: 2.3–2.8%). Our four alternative methods yielded FEV1 and FVC values ≤ 0.08 L different from ATS/ERS standard, which is not clinically meaningful. Intraclass correlation coefficients were ≥ 0.97 indicating consistency across repeated measures. The smallest real differences ranged from FEV1: 0.20–0.27 L and FVC: 0.18–0.24 L indicating consistency and low measurement error. Overall, all methods for reporting FEV1 and FVC demonstrated similar measurement error, precision, and stability within- and between-visits. These results suggest that once ATS/ERS repeatability is achieved, which approach is used for reporting spirometric variables may be of low clinical significance in a healthy population.