Dynamic Footprint Measurement Collection Technique and Intrarater Reliability

2012 ◽  
Vol 102 (2) ◽  
pp. 130-138 ◽  
Author(s):  
Jeanna M. Fascione ◽  
Ryan T. Crews ◽  
James S. Wrobel

Background: Identifying the variability of footprint measurement collection techniques and the reliability of footprint measurements would assist with appropriate clinical foot posture appraisal. We sought to identify relationships between these measures in a healthy population. Methods: On 30 healthy participants, midgait dynamic footprint measurements were collected using an ink mat, paper pedography, and electronic pedography. The footprints were then digitized, and the following footprint indices were calculated with photo digital planimetry software: footprint index, arch index, truncated arch index, Chippaux-Smirak Index, and Staheli Index. Differences between techniques were identified with repeated-measures analysis of variance with post hoc test of Scheffe. In addition, to assess practical similarities between the different methods, intraclass correlation coefficients (ICCs) were calculated. To assess intrarater reliability, footprint indices were calculated twice on 10 randomly selected ink mat footprint measurements, and the ICC was calculated. Results: Dynamic footprint measurements collected with an ink mat significantly differed from those collected with paper pedography (ICC, 0.85–0.96) and electronic pedography (ICC, 0.29–0.79), regardless of the practical similarities noted with ICC values (P = .00). Intrarater reliability for dynamic ink mat footprint measurements was high for the footprint index, arch index, truncated arch index, Chippaux-Smirak Index, and Staheli Index (ICC, 0.74–0.99). Conclusions: Footprint measurements collected with various techniques demonstrate differences. Interchangeable use of exact values without adjustment is not advised. Intrarater reliability of a single method (ink mat) was found to be high. (J Am Podiatr Med Assoc 102(2): 130–138, 2012)

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jennifer H. Therkorn ◽  
Daniella R. Toto ◽  
Michael J. Falvo

AbstractAlternative methods have been proposed to report spirometry indices from test sessions (forced expiratory volume 1 s, FEV1; forced vital capacity, FVC). However, most use the American and European Societies’ standard (ATS/ERS) which stops sessions once a repeatability threshold is met which may not accurately represent intra-session variability. Our goal was to repeat trials beyond the repeatability threshold and evaluate alternative reporting methods. 130 adults performed spirometry across two visits. Spirometry indices were reported using the ATS/ERS standard and four alternatives. 78 participants (60%) had valid data for all methods and visits. Intra-session coefficients of variation were low (FEV1: 3.1–3.7%; FVC: 2.3–2.8%). Our four alternative methods yielded FEV1 and FVC values ≤ 0.08 L different from ATS/ERS standard, which is not clinically meaningful. Intraclass correlation coefficients were ≥ 0.97 indicating consistency across repeated measures. The smallest real differences ranged from FEV1: 0.20–0.27 L and FVC: 0.18–0.24 L indicating consistency and low measurement error. Overall, all methods for reporting FEV1 and FVC demonstrated similar measurement error, precision, and stability within- and between-visits. These results suggest that once ATS/ERS repeatability is achieved, which approach is used for reporting spirometric variables may be of low clinical significance in a healthy population.


PeerJ ◽  
2019 ◽  
Vol 7 ◽  
pp. e8028
Author(s):  
Manuel López-Nicolás ◽  
José A. García-Vidal ◽  
Francesc Medina-Mirapeix ◽  
Joaquín P. Sánchez-Onteniente ◽  
Juan D. Berná Mestre ◽  
...  

Background The aim of this study was to evaluate the effect of different ergonomic supports on the muscle activity of two trunk muscles while a group of dentists performed a common dental procedure on a phantom head, divided into three tasks. Methods A one-way repeated measures study (ANOVA) was conducted on a group of 36 dentists. The middle trapezius and lumbar erector spinae muscles were measured with and without the use of different ergonomic supports (ergonomic stool, magnification lenses and both) using a portable surface electromyography (sEMG) device. Intraclass correlation coefficients (ICCs) and the absolute standard error of measurement (SEM) were used to establish the reliability of the baseline measures without ergonomic supports. Results The sEMG showed excellent ICCs (ranging from 0.92 to 0.99) and SEM. Bonferroni post hoc tests showed differences between the three ergonomic supports (p < 0.001) in both muscles studied. The lowest muscle activity measurement occurred with the isolated used of magnification lenses. The use of the ergonomic stool increased the muscle activity of the middle trapezius and lumbar erector spinae muscles to a greater extent than the magnification lenses. The combination of the ergonomic stool and the magnification lenses produced a different effect on each muscle.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Pieter-Jan Verhelst ◽  
H. Matthews ◽  
L. Verstraete ◽  
F. Van der Cruyssen ◽  
D. Mulier ◽  
...  

AbstractAutomatic craniomaxillofacial (CMF) three dimensional (3D) dense phenotyping promises quantification of the complete CMF shape compared to the limiting use of sparse landmarks in classical phenotyping. This study assesses the accuracy and reliability of this new approach on the human mandible. Classic and automatic phenotyping techniques were applied on 30 unaltered and 20 operated human mandibles. Seven observers indicated 26 anatomical landmarks on each mandible three times. All mandibles were subjected to three rounds of automatic phenotyping using Meshmonk. The toolbox performed non-rigid surface registration of a template mandibular mesh consisting of 17,415 quasi landmarks on each target mandible and the quasi landmarks corresponding to the 26 anatomical locations of interest were identified. Repeated-measures reliability was assessed using root mean square (RMS) distances of repeated landmark indications to their centroid. Automatic phenotyping showed very low RMS distances confirming excellent repeated-measures reliability. The average Euclidean distance between manual and corresponding automatic landmarks was 1.40 mm for the unaltered and 1.76 mm for the operated sample. Centroid sizes from the automatic and manual shape configurations were highly similar with intraclass correlation coefficients (ICC) of > 0.99. Reproducibility coefficients for centroid size were < 2 mm, accounting for < 1% of the total variability of the centroid size of the mandibles in this sample. ICC’s for the multivariate set of 325 interlandmark distances were all > 0.90 indicating again high similarity between shapes quantified by classic or automatic phenotyping. Combined, these findings established high accuracy and repeated-measures reliability of the automatic approach. 3D dense CMF phenotyping of the human mandible using the Meshmonk toolbox introduces a novel improvement in quantifying CMF shape.


Author(s):  
Richard R. Suminski ◽  
Gregory M. Dominick ◽  
Matthew Saponaro

Evidence suggests that video captured with a wearable video device (WVD) may augment or supplant traditional methods for assessing park use. Unmanned aerial systems (UASs) are used to assess human activity, but research employing them for park assessments is sparse. Therefore, this study compared park user counts between a WVD and UAS. A diverse set of 33 amenities (e.g., playground) in three parks were videoed simultaneously by one researcher wearing a WVD and another operating the UAS. Assessments were done at 12 p.m. and 7 p.m. on weekends, with one park evaluated on two occasions 7 days apart. Two investigators independently reviewed videos and reached consensus on the counts of individuals at each amenity. Intraclass correlation coefficients (ICCs) were used to determine intra- and interrater reliabilities. A total of 404 (M = 4.7; SD = 9.6) and 389 (M = 4.5; SD = 9.0) individuals were counted in the UAS and WVD videos, respectively. Absolute agreement was 86% (74/86) and 100% when no individuals were using the amenity. Whether using all 86 videos or only videos having people (48 videos), ICCs indicated excellent reliability (ICC = .99; p < .001). The totals seen for the repeated measures were UAS = 146 and WVD = 136 for Day 1 and UAS = 169 and WVD = 161 for Day 2. Intrarater reliability was excellent for the UAS (ICC = .92; p < .001) and good for the WVD (ICC = .89; p < .001). Disagreement was mainly due to obstructions—people behind or under structures. This study provides support for the use of UASs for counting park users and future research examining the potential benefits of video analysis for assessing park use.


2002 ◽  
Vol 96 (5) ◽  
pp. 1129-1139 ◽  
Author(s):  
Jason Slagle ◽  
Matthew B. Weinger ◽  
My-Than T. Dinh ◽  
Vanessa V. Brumer ◽  
Kevin Williams

Background Task analysis may be useful for assessing how anesthesiologists alter their behavior in response to different clinical situations. In this study, the authors examined the intraobserver and interobserver reliability of an established task analysis methodology. Methods During 20 routine anesthetic procedures, a trained observer sat in the operating room and categorized in real-time the anesthetist's activities into 38 task categories. Two weeks later, the same observer performed task analysis from videotapes obtained intraoperatively. A different observer performed task analysis from the videotapes on two separate occasions. Data were analyzed for percent of time spent on each task category, average task duration, and number of task occurrences. Rater reliability and agreement were assessed using intraclass correlation coefficients. Results Intrarater reliability was generally good for categorization of percent time on task and task occurrence (mean intraclass correlation coefficients of 0.84-0.97). There was a comparably high concordance between real-time and video analyses. Interrater reliability was generally good for percent time and task occurrence measurements. However, the interrater reliability of the task duration metric was unsatisfactory, primarily because of the technique used to capture multitasking. Conclusions A task analysis technique used in anesthesia research for several decades showed good intrarater reliability. Off-line analysis of videotapes is a viable alternative to real-time data collection. Acceptable interrater reliability requires the use of strict task definitions, sophisticated software, and rigorous observer training. New techniques must be developed to more accurately capture multitasking. Substantial effort is required to conduct task analyses that will have sufficient reliability for purposes of research or clinical evaluation.


2006 ◽  
Vol 3 (s2) ◽  
pp. S67-S77 ◽  
Author(s):  
Michelle Ihmels ◽  
Gregory J. Welk ◽  
James J. McClain ◽  
Jodee Schaben

Background:Advances in BIA offer practical alternative approaches to assessing body composition in young adolescents and have not been studied for comparability.Methods:This study compared reliability and convergent validity of three field tests (2-site skinfold, Omron and Tanita BIA devices) on young adolescents. Reliability was determined using intraclass correlation coefficients, convergent validity was examined by computing correlations among the three estimates, differences in estimated body fat values were evaluated using repeated-measures ANOVA, and classification agreement was computed for achieving FITNESSGRAM® Healthy Fitness Zone.Results:ICC values of all three measures exceeded .97. Correlations ranged from .74 to .81 for males and .79 to .91 for females. Classification agreement values ranged from 82.8% to 92.6%.Conclusions:Results suggest general agreement among the selected methods of body composition assessments in both boys and girls with the exception that percent body fat in boys by Tanita BIA is significantly lower than skinfold estimation.


Author(s):  
Megan Sax van der Weyden ◽  
Christopher D. Black ◽  
Daniel Larson ◽  
Brian Rollberg ◽  
Jason A. Campbell

This investigation examined relationships between a Special Weapons and Tactics-specific fitness test (SORT) and an obstacle course (OC) used for qualification in fourteen male SWAT members from three local, regional police departments. The SORT included: squat, pushup, and lunge in 60 s; pullup hold; sled drag; and Yo-Yo Intermittent Recovery Test L1. The obstacle course included: 25 m sprint (repeated); window ascent; scale under a wall; 25 m serpentine run (repeated), body drag (20 m, repeated). Pearson coefficients examined SORT and OC relationships (p ≤ 0.05); intraclass correlation coefficients (ICC2,1) assessed agreement of SORT trials. Repeated measures ANOVA evaluated differences in SORT metrics across time. Coefficients of variation (COV) examined SORT scoring consistency. The YoYo test was related to all SORT assessments (r = −0.803–0.894), except sled drag. The remaining SORT metrics were related to ≥two tests. SORT COVs ranged from 0.77–13.26% for trials 1–2 but decreased between trials 2–3 (0.95–8.97%). The OC was associated with YoYo, lunges, squats and sled drag (r = −0.790, −0.730, −0.766, and 0.802, respectively). No differences (p > 0.05) existed across SORT trials for event scores. The SORT battery appears to be a valid and reliable testing measure to assess SWAT occupational specific fitness.


2020 ◽  
Vol 29 (3) ◽  
pp. 1650-1654
Author(s):  
Cara Donohue ◽  
James L. Coyle

Purpose In dysphagia research involving kinematic analyses on individual swallow parameters, randomization is used to ensure judges are not influenced by judgments made for other parameters within the same swallow or by judgments made for other swallows from the same participant. Yet, the necessity of randomizing swallows to avoid bias during kinematic analyses is largely assumed and untested. This study investigated whether randomization of the order of swallows presented to judges impacts analyses of temporal kinematic events from videofluoroscopic swallow studies. Method One hundred twenty-seven swallows were analyzed from 18 healthy adults who underwent standardized videofluoroscopic swallow studies. Swallows were first analyzed by two trained raters sequentially, analyzing all kinematic events within each swallow, and then a second time in random order, measuring one kinematic event at a time. Intrarater reliability measurements were calculated between random and sequential swallow judgments for all kinematic events using intraclass correlation coefficient and percent exact agreement within a three-frame tolerance. Results Intraclass correlation coefficients (1.00) and percent exact agreement (89%) were excellent for all kinematic events between analyses methods, indicating there were no significant differences in measurements performed in random or sequential order. Conclusions This study provides preliminary evidence that randomization may be unnecessary during temporal swallow kinematic data analyses for research, which may lead to more efficient analyses and dissemination of findings, and alignment of findings with clinical interpretations. Replication of this design with swallows from people with dysphagia would strengthen the generalizability of the results.


Biomechanics ◽  
2020 ◽  
Vol 1 (1) ◽  
pp. 1-14
Author(s):  
Callum Stratford ◽  
Thomas Dos’Santos ◽  
John J. McMahon

The purpose of this study was to identify whether ten repetitions and three trials were necessary to achieve stability in peak reactive strength index (RSI) during the 10/5 repeated jumps test (RJT). Twenty-five males, from multiple sports, performed three trials of the RJT on an in-ground force plate, with 90 seconds’ rest between trials. Intraclass correlation coefficients (ICC = 0.916–0.986) and coefficients of variation (CV ≤ 14.5%) were considered acceptable for all variables. Repeated-measures analysis of variance and Freidman’s tests revealed large and significant differences (p ≤ 0.006, η2 = 0.159–0.434, power ≥ 0.859) in ground contact time (GCT), jump height (JH), and subsequently RSI both between trials and repetitions. Pairwise comparisons revealed that repetitions 1–3 produced longer GCTs (p ≤ 0.05, d = 0.41–1.40), lower JHs (p ≤ 0.05, d = 0.31–0.56), and lower RSI values (p ≤ 0.05, d = 0.35–1.24). The shortest GCTs, greatest JHs and greater RSIs occurred between repetitions 7 and 10, with approximately 60% of peak RSIs occurring during these ranges. The sequential estimate technique revealed that seven repetitions were needed to attain stability in mean peak RSI. Non-significant (p = 0.554) and negligible differences (d ≤ 0.09) in the five best RSIs between trials were noted. One trial of the 10/5 RJT is sufficient to evaluate peak RSI in athletes and should reduce data collection time and fatigue.


Sports ◽  
2019 ◽  
Vol 7 (5) ◽  
pp. 125
Author(s):  
Adam M. Gonzalez ◽  
Gerald T. Mangine ◽  
Robert W. Spitz ◽  
Jamie J. Ghigiarelli ◽  
Katie M. Sell

To determine the agreement between the Open Barbell (OB) and Tendo weightlifting analyzer (TWA) for measuring barbell velocity, eleven men (19.4 ± 1.0 y) performed one set of 2–3 repetitions at four sub-maximal percentage loads, [i.e., 30, 50, 70, and 90% one-repetition maximum (1RM)] in the back (BS) and front squat (FS) exercises. During each repetition, peak and mean barbell velocity were recorded by OB and TWA devices, and the average of the 2–3 repetitions was used for analyses. Although the repeated measures analysis of variance revealed significantly (p ≤ 0.005) greater peak and mean velocity scores from OB across all intensities, high intraclass correlation coefficients (ICC2,K = 0.790–0.998), low standard error of measurement (SEM2,K = 0.040–0.119 m·s−1), and coefficients of variation (CV = 2–4%) suggested consistency between devices. Positive (r = 0.491–0.949) Pearson correlations between averages and differences (between devices) in peak velocity, as well as associated Bland-Altman plots, showed greater differences occurred as the velocity increased, particularly at low-moderate intensity loads. OB consistently provides greater barbell velocity scores compared to TWA, and the differences between devices were more apparent as the peak velocity increased with low-to-moderate loads. Strength coaches and athletes may find better agreement between devices if the mean velocity scores are only considered.