scholarly journals Comparison of Reverse Transcription Loop-Mediated Isothermal Amplification Method with SYBR Green Real-Time RT-PCR and Direct Fluorescent Antibody Test for Diagnosis of Rabies

2020 ◽  
Vol 73 (1) ◽  
pp. 19-25 ◽  
Author(s):  
Elahe Naji ◽  
Zohreh Fadajan ◽  
Davoud Afshar ◽  
Maryam Fazeli
2021 ◽  
Vol 12 ◽  
Author(s):  
Domenico Rizzo ◽  
Daniele Da Lio ◽  
Alessandra Panattoni ◽  
Chiara Salemi ◽  
Giovanni Cappellini ◽  
...  

Tomato brown rugose fruit virus (ToBRFV) represents an emerging viral threat to the productivity of tomato and pepper protected cultivation worldwide. This virus has got the status of quarantine organism in the European Union (EU) countries. In particular, tomato and pepper seeds will need to be free of ToBRFV before entering the EU and before coming on the market. Thus, lab tests are needed. Here, we develop and validate a one-step reverse transcription LAMP platform for the detection of ToBRFV in tomato and pepper leaves, by real-time assay [reverse transcription loop-mediated isothermal amplification (RT-LAMP)] and visual screening (visual RT-LAMP). Moreover, these methods can also be applied successfully for ToBRFV detection in tomato and pepper seeds. The diagnostic specificity and sensitivity of both RT-LAMP and visual RT-LAMP are both 100%, with a detection limit of nearly 2.25 fg/μl, showing the same sensitivity as RT-qPCR Sybr Green, but 100 times more sensitive than end-point RT-PCR diagnostic methods. In artificially contaminated seeds, the proposed LAMP assays detected ToBRFV in 100% of contaminated seed lots, for up to 0.025–0.033% contamination rates in tomato and pepper, respectively. Our results demonstrate that the proposed LAMP assays are simple, inexpensive, and sensitive enough for the detection of ToBRFV, especially in seed health testing. Hence, these methods have great potential application in the routine detection of ToBRFV, both in seeds and plants, reducing the risk of epidemics.


PeerJ ◽  
2020 ◽  
Vol 8 ◽  
pp. e9278 ◽  
Author(s):  
Yee Ling Lau ◽  
Ilyiana Ismail ◽  
Nur Izati Mustapa ◽  
Meng Yee Lai ◽  
Tuan Suhaila Tuan Soh ◽  
...  

Background Highly sensitive real-time reverse transcription polymerase chain reaction (RT-qPCR) methods have been developed for the detection of SARS-CoV-2. However, they are costly. Loop-mediated isothermal amplification (LAMP) assay has emerged as a novel alternative isothermal amplification method for the detection of nucleic acid. Methods A rapid, sensitive and specific real-time reverse transcription LAMP (RT-LAMP) assay was developed for SARS-CoV-2 detection. Results This assay detected one copy/reaction of SARS-CoV-2 RNA in 30 min. Both the clinical sensitivity and specificity of this assay were 100%. The RT-LAMP showed comparable performance with RT-qPCR. Combining simplicity and cost-effectiveness, this assay is therefore recommended for use in resource resource-limited settings.


2018 ◽  
Vol 134 (1) ◽  
pp. 57-62 ◽  
Author(s):  
Kim Appler ◽  
Scott Brunt ◽  
Jodie A. Jarvis ◽  
April D. Davis

Objectives: Each year, rabies virus infection results in the death of more than 50 000 persons worldwide. In the United States, the Centers for Disease Control and Prevention (CDC) reported 23 human rabies cases from May 1, 2008, through October 1, 2017. Although rabies testing in the United States is highly reliable, some specimens submitted to rabies laboratories do not have adequate tissues or may be substantially decomposed. In these instances, the specimen may be considered unsatisfactory for testing or produce indeterminate results using the gold standard direct fluorescent antibody test. The objective of this study was to evaluate the number of unsatisfactory samples or samples with indeterminate results that were positive for rabies virus after additional testing using real-time reverse transcriptase polymerase chain reaction (RT-PCR). Methods: In 2016, we retested all unsatisfactory specimens or specimens with indeterminate results using real-time RT-PCR. We further typed any sample that was real-time RT-PCR positive to identify the infecting rabies virus variant. Results: Of 210 retested unsatisfactory specimens or specimens with indeterminate results, 9 (4.3%) were positive for rabies. In each case, the animal was infected with a homologous rabies virus variant. Conclusion: These results confirm the recommendation by CDC and state public health laboratories that indeterminate results should be considered positive and justify the prompt treatment of exposed persons through an animal that is suspected to have rabies.


Sign in / Sign up

Export Citation Format

Share Document