scholarly journals Antiphospholipid Antibodies and Acquired Thrombophilia: A Biological Marker for Recurrent Miscarriage

Author(s):  
Rania Khogli ELsidig Khogli ◽  
Abdel Rahim Mahmoud Muddathir ◽  
Alaa Eltayeb Omer ◽  
Lienda Bashier Eltayeb

Background: Repeated miscarriage can cause tissue injury can lead to the formation of antibodies to the phospholipids. Recurrent miscarriage (RM) is considering the one of the most common cause of sterility. Which has received more attention in recent years as a result of an increase in the number of reproductive-aged women. Materials and Methods: Plasma samples were tested for antiphospholipid antibodies using ELISA, and platelet count using Sysmex (KX21) Heamatology analyzer and Activated Partial Thromboplastin Time using semi-automated machine (STAGO PT31039352 (for coagulation). Results: The prevalence of Anti phospholipid antibodies (APL) was 30.5% in Sudanese patients with recurrent miscarriage, the prevalence of (Anti phospholipid Antibodies-IgM and IgG) was found to be 23.6% in patients with recurrent miscarriage compared to (Anti phospholipid Antibodies-IgG) was found to be 11.1% ((P value≤0.001), low platelets count (<50×109/l) observed in 10 (13.5%), as well as prolongation of activated partial thromboplastin time (APTT) among studied group were detected among 19 (26.1%). Conclusion: Higher prevalence of antiphospolidids antibodies, and acquired thrombophilia was detected among Sudanese women with recurrent abortion; The findings are concerning because they link an increased risk of thrombosis and a hypercoagulable state lead to recurrent miscarriage in pregnant women.

2007 ◽  
Vol 47 (3) ◽  
pp. 109
Author(s):  
V. Lily Limantara ◽  
Sudaryat S. ◽  
I. B. Mudita ◽  
W. Retayasa ◽  
M. Kardana

Background Low plasma concentration of vitamin K in thenewborn accounts for serious bleeding in the neonatal period andearly infancy. The aim of prophylactic vitamin K is to preventbleeding. Oral prophylaxis is preferable to intramuscular (IM)administration because oral administration is less expensive andless traumatic.Objective To compare oral vs. intramuscular vitamin K onprothrombine time (PT) and activated partial thromboplastin time(APTT) during the first 60 days of life.Methods We randomized newborn infants to either receive oralvitamin K 2 mg at birth and repeated at 7 and 30 days of life orthe 1 mg intramuscular vitamin K. PT and APTT were monitoredat 0, 15, and 45 days of age. Independent t-test, repeatedmeasurement, and regression analysis were used for statisticalanalyses and comparison of the results.Results Fifty infants were assigned into the oral group and 50 tothe IM group. All participants completed 60 days of study. BothPT and APTT decreased after administration of oral or IM vitaminK, and the values did not differ significantly at any time pointand through the period of investigation. Using regression analysisit was shown that only vitamin K administration was correlatedwith PT and APTT with P value were 0.044 and 0.036,respectively. During 60 days of study, there was no hemorrhagicdiathesis in both groups.Conclusions Through the first 60 days of life, 3 doses of oralvitamin K maintain hemostasis by decreasing PT and APTT ininfants at values equal to those achieved by the intramuscularpreparation. Diathesis hemorrhagic event did not occur in bothgroups.


2018 ◽  
Vol 5 (2) ◽  
pp. 419
Author(s):  
Filza Shafi ◽  
Sajad Geelani ◽  
Javid Rasool ◽  
Subuh Parvez Khan ◽  
Syed Mudasir Qadri ◽  
...  

Background: Plasma cell dyscrasia (PCD) is the term used to describe the disorders characterized by neoplastic proliferation of plasma cells with the abnormal production of immunoglobulins (Ig). Patients with multiple myeloma frequently have abnormal coagulation tests. Aim of the present study were to correlate prothrombin time (PT) and Activated Partial Thromboplastin time (aPTT) with Ig concentrations in patients with newly diagnosed with PCD and to compare PT and aPTT values in untreated and treated patients diagnosed with PCDMethods: This study was conducted in the department of clinical hematology of SKIMS, a tertiary care hospital in northern India from 2015 to 2016. Patients diagnosed with PCD were advised for coagulogram (PT, aPTT) as a base line investigation. A total of 72 patients were included in the study.Results: 37% of multiple myeloma cases (newly diagnosed) and 22% of light chain disease patients presented with prolonged PT whereas none of the patients in treated cases of PCD had prolonged PT. The mean Ig concentration was significantly higher in patients with prolonged PT and aPTT compared to that of patients with normal PT and aPTT values. In IgA myeloma, the mean immunoglobulin concentration was 3643 mg/dL with a mean PT and aPTT values of 18.8s and 36.6 (p value: 0.006). The mean free light chain concentration in kappa (k) light chain myeloma was 1727 mg/L with a mean PT value of 20.5 s, mean aPTT value of 37.4 s (p-value: 0.026).Conclusions: Patients with newly diagnosed myeloma presented with prolonged PT as compared to the treated cases. Also, mean Ig concentration was significantly higher in patients with prolonged PT and aPTT compared to that of patients with normal PT and aPTT values.


1992 ◽  
Vol 67 (06) ◽  
pp. 672-678 ◽  
Author(s):  
Barbara M Alving ◽  
Charles F Barr ◽  
Lawrence E Johansen ◽  
Douglas B Tang

SummaryIn the present study, the dilute Russell viper venom time (RVVT) and the dilute phospholipid activated partial thromboplastin time (PL-APTT), which are two assays used for the verification of lupus anticoagulants (LA), were modified to increase standardization. The modified assays were then compared with respect to sensitivity and specificity in detecting LA in plasmas from 72 patients with a prolonged APTT. Modifications included utilizing a single dilution of phospholipid that was either bovine brain thromboplastin (Thrombofax) or liposomes comprised of phosphatidylcholine/phosphatidylserine, and expressing the results as a ratio of the clotting times of the mixture of patient and normal plasma/clotting time of normal plasma. In the RWT, the correlation coefficient between assay results for liposomes and Thrombofax was 0.88 and in the PL-APTT, the correlation was 0.68. A positive test for LA was defined as a ratio of ≥1.3 for the PL-APTT with liposomes and ≥1.2 for the PL-APTT with Thrombofax and the RWT with Thrombofax or liposomes. Regardless of the phospholipid source in the test system, the PL-APTT demonstrated higher sensitivity and the RWT showed greater specificity in detecting patient plasmas that contained antiphospholipid antibodies.


Blood ◽  
2019 ◽  
Vol 133 (13) ◽  
pp. 1507-1516 ◽  
Author(s):  
Alexander W. Koch ◽  
Nikolaus Schiering ◽  
Samu Melkko ◽  
Stefan Ewert ◽  
Janeen Salter ◽  
...  

Abstract A large unmet medical need exists for safer antithrombotic drugs because all currently approved anticoagulant agents interfere with hemostasis, leading to an increased risk of bleeding. Genetic and pharmacologic evidence in humans and animals suggests that reducing factor XI (FXI) levels has the potential to effectively prevent and treat thrombosis with a minimal risk of bleeding. We generated a fully human antibody (MAA868) that binds the catalytic domain of both FXI (zymogen) and activated FXI. Our structural studies show that MAA868 traps FXI and activated FXI in an inactive, zymogen-like conformation, explaining its equally high binding affinity for both forms of the enzyme. This binding mode allows the enzyme to be neutralized before entering the coagulation process, revealing a particularly attractive anticoagulant profile of the antibody. MAA868 exhibited favorable anticoagulant activity in mice with a dose-dependent protection from carotid occlusion in a ferric chloride–induced thrombosis model. MAA868 also caused robust and sustained anticoagulant activity in cynomolgus monkeys as assessed by activated partial thromboplastin time without any evidence of bleeding. Based on these preclinical findings, we conducted a first-in-human study in healthy subjects and showed that single subcutaneous doses of MAA868 were safe and well tolerated. MAA868 resulted in dose- and time-dependent robust and sustained prolongation of activated partial thromboplastin time and FXI suppression for up to 4 weeks or longer, supporting further clinical investigation as a potential once-monthly subcutaneous anticoagulant therapy.


2011 ◽  
Vol 2011 ◽  
pp. 1-5 ◽  
Author(s):  
E. Koumati ◽  
M. Palassopoulou ◽  
P. Matsouka ◽  
A. Polyzos ◽  
G. N. Dalekos ◽  
...  

We report a case of multiple autoimmunity consisting of the presence of autoimmune haemolytic anaemia (AIHA), antimitochondrial antibodies (AMAs), and antiphospholipid antibodies (APLAbs) as the presenting manifestations of an extrahepatic B-non-Hodgkin lymphoma (B-NHL) in a 63-year-old woman. The patient presented with fatigue attributed to severe AIHA. Due to increased serum IgM and -GT levels, an investigation for AMA was performed, which proved positive with anti-M2 specificity. A prolongation of activated partial thromboplastin time (aPTT) led to the determination of APLAbs (lupus anticoagulant and other APLAbs) which were also positive. Bone marrow biopsy in combination with immmunohistochemical studies established the diagnosis of lymphoplasmacytic B-NHL. Ten months later, B-NHL was in remission while AMA and APLAbs were still positive. In conclusion, we documented the coexistence of multiple autoimmune reactions together with B-NHL highlighting the possible common pathogenetic pathways of the two entities.


Blood ◽  
2013 ◽  
Vol 122 (21) ◽  
pp. 2366-2366
Author(s):  
D. Yitzchak Goldstein ◽  
Jacob Rand ◽  
Lucia R Wolgast

Abstract Background Quantification of the risk associated with positive antiphospholipid (aPL) antibodies has been problematic since previous assessments have relied on observing relatively small study populations or meta-analyses of collected larger groups. There would be a significant benefit to a tool that would permit analysis of clinical outcomes of large patient cohorts. We applied a novel analytical information system, named “Clinical Looking Glass” (CLG), which aggregates clinical, diagnostic, therapeutic and outcomes data from a single large academic health care center to address this question. Methods CLG was employed to collect all patients at a large tertiary care institution for whom antiphospholipid antibodies including lupus anticoagulant (LAC), anticardiolipin (aCL) antibodies and anti- β2-glycoproteinI (aβ2GPI) were performed. The immunoassays were grouped by isotype and values of >30U/L (>99th percentile) were considered positive. An untested control group was derived from outcomes data on all institutional Pioneer Accountable Care Organization patients, a cohort, whose coordinated care is managed by a single institution, permitted accurate and robust follow-up data. We used the CLG to track patients for a period of 583 days (maximum data available for control group) following their individual test results to identify a predefined thrombotic outcome. The outcome was defined by any encounter (inpatient, outpatient or ED), subsequent to the initial lab value date, which demonstrated a new thrombotic event. Results Using CLG we were able to evaluate 20,593 unique patients who had some form of LA testing performed. The aCL assays were performed on the greatest number of patients (18,201) followed by the LAC (11,267) with the fewest number of patients tested for aβ2GPI (7,914). A total of 5,660 patients had testing for all three. Of all 11,267 patients having LAC testing performed, 754 patients had at least one positive result. Of these 25.9% went on to develop a thrombotic event during the follow-up period compared to 15.0% of LAC negative patients (p value <0.001) and only 1.64% of the ACO control group suffering an event (p value <0.001). The relative risk associated with LAC positivity over the control group was 14.75 (95% CI 13.6-19.1). All other APL antibodies also demonstrated statistically increased risk of thrombosis over the examined cohort control (RR ranging from 6.6-11.2), but each of these to a significantly lesser degree than when compared directly to the LAC (results summarized in adjoining table and graph). Conclusions This first large study of aPL assays with prospective data from a single clinical information system confirms previous observations from smaller studies that LAC is the most significant laboratory predictor of future thrombotic events. However, in contrast to previous studies, all aPL antibodies, including IgA, demonstrated a statistically increased risk over a control population with LAC positivity having statistically greater risk than all others. Interestingly, aCL IgM was the weakest predictor of a future thrombotic event. Additionally we demonstrate the utility of clinical analytical software tools to offer very powerful ways to test prior assumptions and obtain novel results on large cohorts of patients in “real world” settings. Disclosures: No relevant conflicts of interest to declare.


1991 ◽  
Vol 37 (7) ◽  
pp. 1235-1244 ◽  
Author(s):  
Gabriëlle E Ponjee ◽  
Huib L Vader ◽  
Net J de Wild ◽  
Ger W T Janssen ◽  
Fedde van der Graaf

Abstract We evaluated the clinical usefulness of a recently developed semi-automated one-step chromogenic equivalent of activated partial thromboplastin time (APTT; Behring). This simple test is easily adaptable for automation. Generally, the results with this chromogenic one-step APTT were at least as precise as those obtained with comparative coagulometric methods. The chromogenic one-step APTT showed, both in vitro and in vivo, adequate sensitivity to congenital intrinsic factor deficiency but no sensitivity to Factor VII deficiency. Unlike a two-step coagulometric APTT (Dade), the one-step chromogenic APTT seemed sensitive to activation products of the contact system, which are present in immunoadsorbed factor-deficient plasma. The in vitro sensitivity of the chromogenic APTT to heparin was comparable with that of a coagulometric APTT, but the sensitivity to heparin in patients' samples differed slightly. The chromogenic APTT is relatively insensitive to anomalies in the fibrinogen-fibrin conversion. Finally, we observed discrepancies between the chromogenic and coagulometric APTT results for plasma of patients with disseminated intravascular coagulation. We conclude that this one-step chromogenic APTT warrants further evaluation for possible use as a routine test for the clinical laboratory.


Sign in / Sign up

Export Citation Format

Share Document