This paper presents the design and validation of a neutron survey meter. The meter consists of a PRESCILA neutron probe (with good sensitivity, directional response, gamma rejection, and enhanced high-energy response to 20 MeV) and an electrometer developed at Non-Destructive Evaluation center. The homogeneity response of the PRESCILA neutron probe was investigated as a function of distances from the 241Am - 9Be source in order to obtain the appropriate distance for accurate count-rate measurements using the neutron survey meter. A system consists of the PRESCILA neutron probe and the Ludlum Model 2326 electrometer was then used for measuring neutron ambient dose equivalent rates in the range from 50 cm to 200 cm with the step of 25 cm. The relationship between the count-rates and neutron dose equivalent rates (in the distance ranged from 50 to 200 cm) were deduced to validate the proper operation of the neutron survey meter.


2021 ◽  
Vol 9 (5A) ◽  
pp. 10-18
Author(s):  
Mohd Samsudin Abdul Hamid ◽  
Norul Mas Diyana Ahmad ◽  
Kay Dora Abd Ghani ◽  
Adhilla Ainun Musir ◽  
Daliah Hassan ◽  
...  

2021 ◽  
Vol 7 (3) ◽  
pp. 25-33
Author(s):  
Duc Tuan Nguyen ◽  
Van Dien Mai ◽  
Duc Ky Bui ◽  
Vu Long Chu ◽  
Van Tien Vu ◽  
...  

For personal radiation dose monitoring, electronic personal dosimeters (EPD), also known as active personal dosimeter (APD), using silicon diode detector have the advantage capability of measuring and displaying directly the exposure results of gamma, beta and neutron radiations in real time. They are mainly considered as good complement to passive dosimeters to satisfy ALARA principle in the radiation protection. In this paper, the meansurement methods and algorithms for evaluating personal dose equivalents such as Hp(10) and Hp(0.07) from air-kerma are studied and developed in two directions: the first, named energy correction method based on incident energy determined by the ratio of two detector responses with the different filter configurations; the second new method is carried out in the way that matching the shape of a detector’s energy response curve to the kerma-to-personal dose equivalent conversion function provides an approximate means of determining the dose equivalent without the need to resolve the actual incident energies. The algorithm has also been experimentally verified at Secondary Standards Dosimetry Laboratory (SSDL) of INST by the beam of radiation defined in ISO 4037-1. The obtained results of personal dose equivalents with errors almost less than 30% in energy range from 20 keV to 1.5 MeV are partially met the EPD design requirements according to the IEC 61526 Standard. The work and results of described in this paper are important basics for design and construction of completed electronic personal dosimeter.


2021 ◽  
Vol 263 (4) ◽  
pp. 2812-2821
Author(s):  
Jared Miller ◽  
Scott D. Sommerfeldt ◽  
Jonathan D. Blotter ◽  
David C. Copley

Many methods for simulating acoustic responses of vibrating systems are only suitable for limited frequency ranges, providing either an accurate low frequency or high frequency response. A hybrid method is presented to combine a low frequency modal response and a high frequency statistical energy response to obtain a unified broadband response. The method is designed to produce an auralizable response. An experimental setup is used to validate the method. Listening tests are conducted to assess the realism of the auralizations compared to measurements. The listening tests confirm that the method is able to produce realistic auralizations, subject to a few limitations.


2021 ◽  
Vol 81 (6) ◽  
Author(s):  
Jalal Abdallah ◽  
Stylianos Angelidakis ◽  
Giorgi Arabidze ◽  
Nikolay Atanov ◽  
Johannes Bernhard ◽  
...  

AbstractThree spare modules of the ATLAS Tile Calorimeter were exposed to test beams from the Super Proton Synchrotron accelerator at CERN in 2017. The detector’s measurements of the energy response and resolution to positive pions and kaons, and protons with energies ranging from 16 to 30 GeV are reported. The results have uncertainties of a few percent. They were compared to the predictions of the Geant4-based simulation program used in ATLAS to estimate the response of the detector to proton-proton events at the Large Hadron Collider. The determinations obtained using experimental and simulated data agree within the uncertainties.