b scan images
Recently Published Documents


TOTAL DOCUMENTS

109
(FIVE YEARS 24)

H-INDEX

15
(FIVE YEARS 3)

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Takuhei Shoji ◽  
Hirokazu Ishii ◽  
Junji Kanno ◽  
Takanori Sasaki ◽  
Yuji Yoshikawa ◽  
...  

AbstractThe center of the fovea, termed the foveola, is the area of highest visual acuity, has the highest density of cone photoreceptors. We investigated the distance between the automatically-determined center of the foveal avascular zone (FAZ) and the manually-determined highest foveal bulge (FB) point using single swept-source optical coherence tomography angiography (OCTA) instrument. This cross-sectional study included 49 eyes of 49 individuals (34 women and 15 men; median age: 68 years) with no history of ocular disorders. The FAZ in the superficial capillary plexus was automatically determined using the Kanno–Saitama macro method, and the center of the FAZ was automatically determined using ellipse approximation. Another candidate foveal center, the highest FB point, was determined manually on the serial cross-sectional B-scan images. As a result, the foveal center was manually identified as the highest FB point on B-scan OCTA images. The center of the FAZ was more likely to be located inferior to the highest FB point (p = 0.031). In participants with a total (linear) distance of more than 50 μm between the center of the FAZ and the highest FB point, the displacement was significantly more in the horizontal direction than in the vertical direction (p = 0.017). These results can be applicable to further studies regarding the spatial relationships between the center of the FAZ and the highest FB point in various macular diseases or previously-treated eyes.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yoshiaki Chiku ◽  
Takao Hirano ◽  
Yoshiaki Takahashi ◽  
Ayako Tuchiya ◽  
Marie Nakamura ◽  
...  

AbstractPosterior vitreous detachment (PVD) is a separation between the posterior vitreous cortex and internal limiting membrane. Although PVD was historically considered an acute event, recent studies using spectral-domain optical coherence tomography (SD-OCT) revealed a gradual progression of PVD in healthy subjects. Although SD-OCT improved PVD studies, the narrow imaging angle and long examination time were problematic to allow wide angle capture. The Xephilio OCT-S1 (Canon), a swept-source OCT (SS-OCT) device, can obtain up to 23-mm of widefield B-scan images in a single acquisition. We used this widefield SS-OCT to quantitatively evaluate the PVD stage in 214 healthy subjects aged 4–89 years and determine whether PVD stages differ between the bilateral eyes of each patient. Age was significantly positively correlated with the overall PVD stage (ρ = 0.7520, P < 0.001). Interestingly, partial PVD occurred in children as young as 5 years, indicating that initial PVD onset may occur much earlier than previously reported. Furthermore, PVD stages of the bilateral eyes were highly consistent in 183 subjects (85.5%). Widefield 23-mm SS-OCT thus revealed that PVD started earlier than anticipated, and age was correlated with the symmetry of PVD stage. Widefield 23-mm SS-OCT may also be clinically useful for the evaluation of diseased eyes.


2021 ◽  
Vol 15 (9) ◽  
pp. 2766-2769
Author(s):  
Hijab Fatemah Memon ◽  
Suraiya Hirani ◽  
Jaweria Yousfani ◽  
Reema Aslam ◽  
Sehar Mushtaque ◽  
...  

Introduction: Optical Coherence Tomography (OCT), is one of the most emerging diagnostic imaging technique. It is capable of producing 3D images using optical scattering media. The fast signal acquisition quality has made it a promising tool to detect early in vivo and in vitro lesions. The aim of this study was to reproduce previous demineralization results and to detect remineralization using OCT. Methodology: Bovine enamel discs were used thoroughly in this study. The study was done using the flow cell for detecting demineralization and remineralization following 96 hours demineralization and 192 hours remineralization. A time lapse monitoring was done and the lesions were assessed visually. ImageJ software was used to process the images produced through OCT. The lesion depth and intensity was measured across the images produced which helped in assessing the difference between remineralization and demineralization. Results: OCT B-scan images result in increased backscattering light which is considered the main principle to measure lesion depth and mineral loss. Whereas, in remineralization decreased band of light appeared with reduction in porosity during mineral precipitation. The results for remineralization were diverse and could not be assessed. Conclusion: OCT is favorable technique to detect demineralization and remineralization but it still needs a lot of improvement especially regarding remineralization there are limitations which need to be improved.


Author(s):  
Zhengxing Chen ◽  
Qihang Wang ◽  
Kanghua Yang ◽  
Tianle Yu ◽  
Jidong Yao ◽  
...  

Rail defect detection is crucial to rail operations safety. Addressing the problem of high false alarm rates and missed detection rates in rail defect detection, this paper proposes a deep learning method using B-scan image recognition of rail defects with an improved YOLO (you only look once) V3 algorithm. Specifically, the developed model can automatically position a box in B-scan images and recognize EFBWs (electric flash butt welds), normal bolt holes, BHBs (bolt hole breaks), and SSCs (shells, spalling, or corrugation). First, the network structure of the YOLO V3 model is modified to enlarge the receptive field of the model, thus improving the detection accuracy of the model for small-scale objects. Second, B-scan image data are analyzed and standardized. Third, the initial training parameters of the improved YOLO V3 model are adjusted. Finally, the experiments are performed on 453 B-scan images as the test data set. Results show that the B-scan image recognition model based on the improved YOLO V3 algorithm reached high performance in its precision. Additionally, the detection accuracy and efficiency are improved compared with the original model and the final mean average precision can reach 87.41%.


Sensors ◽  
2021 ◽  
Vol 21 (14) ◽  
pp. 4670
Author(s):  
Yoonseok Kim ◽  
Gu-In Jung ◽  
Deokmin Jeon ◽  
Ruchire Eranga Wijesinghe ◽  
Daewoon Seong ◽  
...  

The aim of this study was to quantitatively assess the residual adhesive on orthodontic ceramic bracket-removed dental surface. In orthodontic process, ceramic bracket was repeated debonding physically, then the adhesive remained on the dental surface. The residual adhesive caused a lack of adhesive strength between dental and ceramic bracket. Since commonly used adhesive in orthodontics is translucent, residual adhesive is hard to be detected with conventional microscopes. Therefore, 1310 nm center wavelength swept-source OCT system based on laboratory customized image processing algorithm was used for the precise detection of residual adhesive on tooth surface. The algorithm separates residual adhesive from dental surface by comparing the height of adjacent B-scan images, while providing color-scaled images emphasizing the thickness information of residual adhesive. Finally, the acquired results were compared with microscopic and adhesive remnant index scoring gold standards, while the comparison confirmed the potential merits and the improvements of the proposed method over gold standards.


2021 ◽  
Author(s):  
Yoshiaki Chiku ◽  
Takao Hirano ◽  
Yoshiaki Takahashi ◽  
Ayako Tuchiya ◽  
Marie Nakamura ◽  
...  

Abstract Posterior vitreous detachment (PVD) is a separation between the posterior vitreous cortex and internal limiting membrane. Although PVD was historically considered an acute event, recent studies using spectral-domain optical coherence tomography (SD-OCT) revealed a gradual progression of PVD in healthy subjects. Although SD-OCT improved PVD studies, the narrow imaging angle and long examination time were problematic to allow wide angle capture. The Xephilio OCT-S1 (Canon), a swept source OCT (SS-OCT) device, can obtain up to 23-mm of widefield B-scan images in a single acquisition. We used this widefield SS-OCT to quantitatively evaluate the PVD stage in 214 healthy subjects aged 4–89 years and determine whether PVD stages differ between the bilateral eyes of each patient. Age was significantly positively correlated with overall PVD stage (ρ=0.7520, P<0.001). Interestingly, partial PVD occurred in children as young as 5 years old, indicating that initial PVD onset may occur much earlier than previously reported.Furthermore, PVD stages of the bilateral eyes were highly consistent in 183 subjects (85.5%). Widefield 23-mm SS-OCT thus revealed that PVD started earlier than anticipated, and age is correlated with the symmetry of PVD stage. Widefield 23-mm SS-OCT may also be clinically useful for the evaluation of diseased eyes.


Polymers ◽  
2021 ◽  
Vol 13 (9) ◽  
pp. 1462
Author(s):  
Abhishek Ranjan ◽  
Chengxiang Peng ◽  
Sanat Wagle ◽  
Frank Melandsø ◽  
Anowarul Habib

The piezoelectric polymer PVDF and its copolymers have a long history as transducer materials for medical and biological applications. An efficient use of these polymers can potentially both lower the production cost and offer an environment-friendly alternative for medical transducers which today is dominated by piezoelectric ceramics containing lead. The main goal of the current work has been to compare the image quality of a low-cost in-house transducers made from the copolymer P(VDF-TrFE) to a commercial PVDF transducer. Several test objects were explored with the transducers used in a scanning acoustic microscope, including a human articular cartilage sample, a coin surface, and an etched metal film with fine line structures. To evaluate the image quality, C- and B-scan images were obtained from the recorded time series, and compared in terms of resolution, SNR, point-spread function, and depth imaging capability. The investigation is believed to provide useful information about both the strengths and limitations of low-cost polymer transducers.


Author(s):  
Ahmed Allam ◽  
Christopher Sugino ◽  
Matthew Harding ◽  
D. Paul Bishop ◽  
Alper Erturk ◽  
...  

Abstract We investigate the use of phased array ultrasonic testing (PAUT) as an offsite non-destructive quality assurance technique for parts made by Selective laser melting (SLM). SLM is a popular additive manufacturing (AM) approach for fabricating high value metallic components with complex geometries. Slight variations in the laser power during fabrication might lead to internal defect development within the part, which could compromise its mechanical strength and fatigue life. PAUT is employed to detect typical internal porosity generated in Inconel 625 samples due to laser power fluctuation during SLM. The typical defect size, shape and distribution are first identified using metallography and X-ray computed tomography (XCT). B-scan images of the defect region is then generated experimentally using a 5 MHz linear UT phased array probe. Finite elements simulate wave propagation using geometries obtained from XCT images. The simulation results are compared to the experimental imaging of large defect regions and then used to generate total focusing method images of isolated clusters of 50-200 µm defects. The testing technique illustrates a successful application of PAUT for quality inspection of SLM parts.


2021 ◽  
Vol 11 (7) ◽  
pp. 3119
Author(s):  
Cristina L. Saratxaga ◽  
Jorge Bote ◽  
Juan F. Ortega-Morán ◽  
Artzai Picón ◽  
Elena Terradillos ◽  
...  

(1) Background: Clinicians demand new tools for early diagnosis and improved detection of colon lesions that are vital for patient prognosis. Optical coherence tomography (OCT) allows microscopical inspection of tissue and might serve as an optical biopsy method that could lead to in-situ diagnosis and treatment decisions; (2) Methods: A database of murine (rat) healthy, hyperplastic and neoplastic colonic samples with more than 94,000 images was acquired. A methodology that includes a data augmentation processing strategy and a deep learning model for automatic classification (benign vs. malignant) of OCT images is presented and validated over this dataset. Comparative evaluation is performed both over individual B-scan images and C-scan volumes; (3) Results: A model was trained and evaluated with the proposed methodology using six different data splits to present statistically significant results. Considering this, 0.9695 (±0.0141) sensitivity and 0.8094 (±0.1524) specificity were obtained when diagnosis was performed over B-scan images. On the other hand, 0.9821 (±0.0197) sensitivity and 0.7865 (±0.205) specificity were achieved when diagnosis was made considering all the images in the whole C-scan volume; (4) Conclusions: The proposed methodology based on deep learning showed great potential for the automatic characterization of colon polyps and future development of the optical biopsy paradigm.


Sign in / Sign up

Export Citation Format

Share Document