valve actuation
Recently Published Documents


TOTAL DOCUMENTS

243
(FIVE YEARS 36)

H-INDEX

22
(FIVE YEARS 3)

Energies ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 438
Author(s):  
Linghai Han ◽  
Jiaquan Duan ◽  
Dingchao Qian ◽  
Yanfeng Gong ◽  
Yaodong Wang ◽  
...  

The thermal efficiency of an efficient gasoline engine is only about 40% and it will produce a large number of harmful products. Curbing harmful emissions and enhancing thermal efficiency have always been the goals pursued and emission regulations are also being tightened gradually. As one of the main consumers of fossil fuels, automobile engines must further reduce fuel consumption and emissions to comply with the concept of low-carbon development, which will also help them compete with electric vehicles. Homogeneous charge compression ignition (HCCI) combustion combined with variable valve actuation (VVA) technology is one of the important ways to improve engine emissions and economy. HCCI combustion based on VVA can only be realized at small and medium loads. The actual application on the entire vehicle needs to be combined with spark ignition (SI) combustion to achieve full working condition coverage. Therefore, HCCI combustion needs fast valve response characteristics; however, the valve lift and timing of the existing VVA mechanisms are mostly controlled separately, resulting in poor valve response. In order to solve this problem, the cam driven hydraulic variable valve actuation (CDH-VVA) mechanism was designed. The valve lift and timing can be adjusted at the same time and the switching of valve lift and timing can be completed in 1~2 cycles. A set of combustion mode switching data is selected to show the response characteristics of the CDH-VVA mechanism. When switching from spark ignition (SI) to HCCI, it switches to HCCI combustion after only one combustion cycle and it switches to stable HCCI combustion after two combustion cycles, which proves the fast response characteristics of the CDH-VVA mechanism. At the same time, the CDH-VVA mechanism can form the intake port exhaust gas recirculation (EGR), as one type of internal EGR. This paper studies the HCCI combustion characteristics of the CDH-VVA mechanism in order to optimize it in the future and enable it to realize more forms of HCCI combustion. At 1000 rpm, if the maximum lift of the exhaust valve (MLEV) is higher than 5.0 mm or lower than 1.5 mm, HCCI combustion cannot operate stably, the range of excess air coefficient (λ) is largest when the MLEV is 4.5 mm, ranging from 1.0~1.5. Then, as the MLEV decreases, the range of λ becomes smaller. When the MLEV drops to 1.5 mm, the range of λ shortens to 1.0~1.3. The maximum value of the MLEV remains the same at the three engine speeds (1000 rpm, 1200 rpm and 1400 rpm), which is 5.0 mm. The minimum value of the MLEV gradually climbs as the engine speed increase, 1000 rpm: 1.5 mm, 1200 rpm: 2.0 mm, 1400 rpm: 3.0 mm. With the increase of engine speed, the range of indicated mean effective pressure (IMEP) gradually declines, 3.53~6.31 bar (1000 rpm), 4.11~6.75 bar (1200 rpm), 5.02~6.09 bar (1400 rpm), which proves that the HCCI combustion loads of the intake port EGR are high and cannot be extended to low loads. The cyclic variation of HCCI combustion basically climbs with the decrease of the MLEV and slightly jumps with the increase of the engine speed. At 1000 rpm, when the MLEV is 5.0 mm, the cyclic variation range is 0.94%~1.5%. As the MLEV drops to 1.5 mm, the cyclic variation range rises to 3.5%~4.5%. Taking the maximum value of the MLEV as an example, the cyclic variation range of 1000 rpm is 0.94%~1.5%, 1200 rpm becomes 1.5%~2.3% and 1400 rpm rises to 2.0%~2.5%.


Author(s):  
Tobias Vonderbank ◽  
Pierre Marc Laßl Chavez ◽  
Katharina Schmitz

Extensive actuation forces and strokes are required for the actuation of large sized valves normally implemented in high power hydraulic systems. A hydraulically piloted operation is, for now, the most suitable solution and state of the art. However, there are some applications where electromechanical valve actuation systems are at advantage against common pilot operation systems. In this contribution it is analyzed in which cases the application of electro-mechanical actuators can be of advantage and why displacement-controlled systems may be one of these applications. A novel electromechanical valve actuation system for large sized 4/3-way directional control valves for the use in displacement-controlled systems is presented. This new actuation system is characterized by a hydraulic relief of the centering springs. Therefore, the springs are only active in safety-critical conditions, such as a power outage. Since the actuator is not working against the spring force during every displacement, the necessary actuation force is reduced drastically. Thus, common electromechanical actuators can be used. In case of a power outage, the spring relief is deactivated causing the stored energy to center the spool in its neutral position. The performance of the novel actuation system is examined through measurements conducted on a manufactured demonstrator for valves of nominal size 25 with a flow rate of up to 600 l/min.


2021 ◽  
Author(s):  
Srinibas Tripathy ◽  
Mithun Babu M. ◽  
Kanupriya M. ◽  
Mayank Mittal

Abstract Improving internal combustion engine performance is a significant concern over the past few decades for engine researchers and automobile manufacturers. One of the promising methods for improving the engine performance is variable valve actuation system with camless technology. In the camless system, the conventional spring-operated valve actuation mechanism is removed, and an actuator is used to independently control the valve events (lift, timing, and duration). Among different camless systems, electromagnetic variable valve actuation (EMVA) becomes more viable because of its faster valve operation. However, the major challenge is to control the valve seating velocity (velocity at which valve comes to rest during seating on the cylinder head) due to the absence of the cam mechanism. A sophisticated control system must be developed to achieve an acceptable valve seating velocity. In this study, a proportional-integral-derivative (PID) controller was used to control the EMVA system. A machine learning tool, i.e., genetic algorithm, and an iterative method, i.e., Ziegler-Nichols, were used to optimize the PID controller’s gain values. The valve lift profiles obtained using the Ziegler-Nichols method and the genetic algorithm were compared. It was found that the developed algorithm for the EMVA system can achieve faster rise time compared to the experimental results [25] utilized inverse square method. A parametric investigation was performed to verify the robustness of the PID controller with a change in temperature. It is concluded that the temperature rise may increase the resistance and inductance, but the controller with the updated gain values can control the EMVA system without affecting the performance parameter. The simulation was performed for both forward and backward strokes to investigate the valve seating velocity. It was found that the controller can achieve an acceptable valve seating velocity. Hence, the machine learning tool helps in optimizing the PID controller’s gain values to achieve faster valve operation with an acceptable valve seating velocity.


Actuators ◽  
2021 ◽  
Vol 10 (6) ◽  
pp. 133
Author(s):  
Tobias Vonderbank ◽  
Katharina Schmitz

Increasing performance in modern hydraulics is achieved by a close investigation of possible enhancements of its components. Prior research has pointed out that electromechanical actuators can form suitable alternatives to hydraulically piloted control systems. Since the requirements at these actuation systems depend on the operating conditions of the system, each actuator can be optimized to the respective hydraulic system. Considering that many different conceptual designs are suitable, the phase of conceptual design plays a decisive role during the design process. Therefore, this paper focuses on the process of developing new conceptual designs for electromechanical valve actuation systems using the method of function structures. Aiming to identify special design features, which need to be considered during the design process of electromechanical actuation systems, an exemplary actuator was designed based on the derived function structure. To highlight the potential of function structures for the development of new electromechanical valve actuation systems, two principal concepts, which allow the reduction of the necessary forces, have been developed by extending the function structure. These concepts have been experimentally investigated to identify their advantages and disadvantages.


Mechatronics ◽  
2021 ◽  
Vol 73 ◽  
pp. 102479
Author(s):  
Junjie Pan ◽  
Amir Khajepour ◽  
Yangtao Li ◽  
Jing Yang ◽  
Weiqiang Liu

Sign in / Sign up

Export Citation Format

Share Document