scholarly journals Reliability of resting metabolic rate between and within day measurements using the Vyntus CPX system and comparison against predictive formulas

2021 ◽  
pp. 026010602110573
Author(s):  
J. Iraki ◽  
G. Paulsen ◽  
I. Garthe ◽  
G. Slater ◽  
J.L. Areta

Background: To detect longitudinal changes of resting metabolic rate (RMR) resulting from the effects of energetic stress, reliable RMR measurements are crucial. The Vyntus CPX is a new automated indirect calorimetry system for which RMR reliability has not been determined. Additionally, its agreement with common predictive RMR formulas is unknown. Aim: To determine the within and between-day reliability of RMR measurements using the Vyntus CPX system and its agreement with predictive RMR formulas. Methods: Young (31  ±  7 years) healthy participants (n = 26, 12 females, 14 males) completed three measurements of RMR, two consecutive measures on the same day, one the day before/after, all under standardised conditions. Reliability was assessed with pairwise comparisons of between-day at the same time (BDST), within day consecutive measurements (WDCM) and between-day different time (BDDT), for parameters of reliability (mean change (MC), intraclass correlation (ICC) and typical error of measurement (TEM)). Measured RMR values (kcal/day) were compared against predictive values of 4 common formulas. Results: Parameters of reliability (mean, (95% confidence interval)) were: -BDST: MC, 0.2(-2.3—2.7)% (p = 0.67); ICC, 0.92(0.84—0.97); TEM, 4.5(3.5—6.2)%. -WDCM: MC, −2.5(-6.2—1.3)% (p = 0.21); ICC, 0.88(0.74—0.88); TEM, 7.0(5.4—9.8)%. -BDDT: MC, −1.5(-4.8—1.9)% (p = 0.57); ICC, 0.90(0.76—0.95); TEM, 6.1(4.8—8.5)%. RMRratios (measured/predicted) were: 1.04  ±  0.14 (Nelson, p = 0.13), 1.03  ±  0.10 (Mifflin, p = 0.21), 0.98  ±  0.09 (Harris-benedict, p = 0.30), 0.95  ±  0.11 (Cunningham1980, p = 0.01), 1.00  ±  0.12 (Cunningham1991, p = 0.90) and 0.96  ±  0.13 (DXA, p = 0.03). Conclusions: The Vyntus CPX is reliable and measured RMR values agreed with four predictive formulas but are lower than Cunningham1980 and DXA RMR estimates for this population.

Author(s):  
Hichem Chtara ◽  
Yassine Negra ◽  
Helmi Chaabene ◽  
Moktar Chtara ◽  
John Cronin ◽  
...  

The aim of this study was to validate a new test of change of direction (COD) for fencer athletes and to establish its relationship with selected measures of physical fitness. Thirty-nine fencer athletes participated to this study (age: 20.8 ± 3.0 years). They performed the new specific fencing COD test (SFCODT) on two separate occasions to establish its reliability. In addition, assessment of COD, jumping ability (i.e., squat jump, countermovement jump, five jump test), sprint time (e.g., 5-m, 10-m and 20-m), isokinetic concentric and eccentric quadriceps, and hamstring force tests were assessed. To establish SFCODT’s construct validity, two subgroups were identified based on their international and national fencing results: High- vs. low-ranked fencer athletes. Reliability, validity, and sensitivity of the SFCODT were established from the intraclass correlation coefficient (ICC), typical error of measurement (TEM), smallest worthwhile change (SWC), and receiving operator characteristic (ROC) analysis. The ICC of SFCODT was excellent at >0.95, and the TEM was < 5%. Based on the usefulness analysis, the ability to detect small performance changes can be rated as “good” in fencer athletes (SWC > TEM). SFCODT was very largely associated with the COD test and moderate to very large associated with jumping ability, sprint time, and isokinetic strength. High-ranked fencer athletes were better than low-ranked fencer athletes on SFCODT (p < 0.01). The area under the ROC curve was 0.76. In conclusion, the SFCODT is a highly reliable, valid, and sensitive test. Therefore, the SFCODT could be used by practitioners to evaluate specific CODS performance in fencer athletes.


2021 ◽  
Vol 6 (2) ◽  
pp. 41
Author(s):  
Senda Sammoud ◽  
Raja Bouguezzi ◽  
Yassine Negra ◽  
Helmi Chaabene

Background: This study aimed to examine the reliability and sensitivity of a change of direction deficit (CoDD) and to establish its relationship with linear sprint speed. Methods: In total, 89 prepubertal male soccer players participated in this study (age = 11.7 ± 1.2 years, maturity offset = −2.4 ± 1.0). Participants performed the 505 CoD speed test and the 20 m linear sprint speed test with a split interval at 5 m and 10 m. The CoDD was calculated as the mean 505 CoD time—the mean 10 to 20 m time interval. To evaluate the reliability of CoDD, the 505 CoD speed test, and 20 m linear sprint speed were performed twice, one week apart. The sensitivity of CoDD was identified by comparing the values of the typical error of measurement (TEM) and smallest worthwhile change (SWC). Results: Results of the reliability analysis indicated an intraclass correlation coefficient (ICC3.1) < 0.50 (0.47) and a TEM expressed as the coefficient of variation > 5% (10.55%). The sensitivity analysis showed that the ability of the CoDD measure to detect small performance changes is “marginal” (TEM (0.12) > SWC0.2 (0.04)). However, good absolute and relative reliability were observed for the 505 CoD speed test (ICC3.1 = 0.75; TEM < 5%). Alike CoDD, the ability of the 505 CoD speed test to detect small performance changes was rated as “marginal” (TEM (0.07 s) > SWC0.2 (0.04 s)). The CoDD revealed a large association with the 505 CoD speed test (r = 0.71). However, non-significant associations were detected between the CoDD and 5 m, 10 m, and 20 m linear sprint speed intervals (r = 0.10 to 0.16, all p > 0.05). Likewise, non-significant correlations between the 505 CoD speed test and 5 m, 10 m, and 20 m linear sprint speed intervals were observed (r = 0.14 to 0.20, all p > 0.05). Conclusions: The CoDD displayed poor reliability and limited ability to detect small changes in performance in prepubertal male soccer players. Due to its limited practical utility, practitioners are advised not to consider CoDD scores during the assessment of prepubertal male soccer players.


2016 ◽  
Vol 26 (5) ◽  
pp. 454-463 ◽  
Author(s):  
Amy L. Woods ◽  
Laura A. Garvican-Lewis ◽  
Anthony J. Rice ◽  
Kevin G. Thompson

The aim of the current study was to determine if a single ParvoMedics TrueOne 2400 metabolic cart provides valid and reliable measurement of RMR in comparison with the criterion Douglas Bag method (DB). Ten endurance-trained participants completed duplicate RMR measurements on 2 consecutive days using the ParvoMedics system in exercise mode, with the same expirate analyzed using DB. Typical error (TE) in mean RMR between the systems was 578.9 kJ or 7.5% (p = .01). In comparison with DB, the ParvoMedics system over-estimated RMR by 946.7 ± 818.6 kJ. The bias between systems resulted from ParvoMedics VE(STPD) values. A regression equation was developed to correct the bias, which reduced the difference to -83.3 ± 631.9 kJ. TE for the corrected ParvoMedics data were 446.8 kJ or 7.2% (p = .70). On Day 1, intraday reliability in mean RMR for DB was 286.8 kJ or 4.3%, (p = .54) and for ParvoMedicsuncorrected, 359.3 kJ or 4.4%, (p = .35), with closer agreement observed on Day 2. Interday reliability for DB was 455.3 kJ or 6.6% (p = .61) and for ParvoMedicsuncorrected, 390.2 kJ or 6.3% (p = .54). Similar intraday and interday TE was observed between ParvoMedicsuncorrected and ParvoMedicscorrected data. The ParvoMedics TrueOne 2400 provided valid and reliable RMR values compared with DB when the VE(STPD) error was corrected. This will enable widespread monitoring of RMR using the ParvoMedics system in a range of field-based settings when DB is not available.


2006 ◽  
Vol 1 (2) ◽  
pp. 95-107 ◽  
Author(s):  
Tim J. Gabbett ◽  
Boris Georgieff

Purpose:To develop a skill assessment for junior volleyball players and to evaluate the reliability, validity, and sensitivity of the test for detecting training-induced improvements in skill.Methods:Thirty junior volleyball players (mean ± SD age, 15.5 ± 1.0 years) participated in this study. Subjects performed tests of spiking, setting, serving, and passing skills on 2 separate occasions to determine test–retest reliability of accuracy. Two expert coaches evaluated the players’ technique and reevaluated it 1 month after the initial evaluation to determine the intratester reliability for technique measurements. A third expert coach determined the intertester reliability for technique measurements. The validity of the test to discriminate players of different playing abilities was evaluated by testing junior national, state, and novice volleyball players. Finally, each player participated in an 8-week skill-based training program.Results:Accuracy measurements and intratester and intertester ratings of players’ technique proved to be highly reproducible (intraclass correlation coefficient, r, .85 to .98, range of typical error of measurement 0.2% to 10.0%). A progressive improvement in skill was observed with increases in playing level, while training-induced improvements were present in all skill tasks.Conclusions:These results demonstrate that skill-based testing offers a reliable method of quantifying development and progress in junior volleyball players. In addition, the skill-testing battery was useful in successfully discriminating playing ability among junior volleyball players of varying levels, and it was sensitive to changes in skill with training. These fi ndings demonstrate that skill-based testing is useful for monitoring the development of junior volleyball players.


2015 ◽  
Vol 10 (2) ◽  
pp. 160-165 ◽  
Author(s):  
Anne Delextrat ◽  
Bernard Grosgeorge ◽  
Francois Bieuzen

Purpose:To investigate the reliability and determinants of performance in a new test of planned agility in elite junior basketball players.Methods:Seventeen female (15.1 ± 0.4 y, 176.9 ± 11.2 cm, 65.7 ± 10.9 kg) and 42 male (14.9 ± 0.4 y, 193.7 ± 8.1 cm, 79.0 ± 12.0 kg) elite junior basketball players performed 5 fitness tests presented in a random order, including a 20-m sprint, a planned-agility test, a triple bilateral horizontal countermovement jump, and 2 triple unilateral horizontal countermovement jumps (with each leg separately). The novelty of the planned-agility test is that it included both offensive and defensive movements. The determinants of planned agility were assessed by a stepwise-regression analysis, and the reliability of the new test was evaluated by the intraclass correlation coefficient and the typical error of measurement.Results:The main results show good reliability of the new test of planned agility. In addition, the determinants of planned-agility performance were different between genders, with sprint performance explaining 74.8% of the variance for girls, while unilateral jump performance and body mass were the most important for boys, accounting for 24.0% and 8.9% of the variance, respectively, in planned agility.Conclusions:These results highlight a gender effect on the determinants of planned-agility performance in young elite basketball players and suggest that straight-line sprint and unilateral horizontal tests must be implemented to test elite junior players.


2018 ◽  
Vol 28 (5) ◽  
pp. 464-467 ◽  
Author(s):  
Julia L. Bone ◽  
Louise M. Burke

Low energy availability can place athletes at increased risk of injury and illness and can be detected by a lower metabolic rate. The lowest metabolic rate is captured at the bedside, after an overnight fast and termed inpatient resting energy expenditure (REE). Measurements done in a laboratory with a shorter overnight fast are termed outpatient REE. Although important to know what the lowest energy expenditure, a bedside measure and/or 12-hr fast is not always practical or logistically possible particularly when you take into account an athlete’s training schedule. The aim of this investigation was to compare a bedside measure of resting metabolism with a laboratory measure in athletes following an 8-hr fast. Thirty-two athletes (24 females and eight males) underwent measures of resting metabolism using indirect calorimetry once at their bedside (inpatient) and once in a simulated laboratory setting (outpatient). Paired t test was used to compare the mean ± SD differences between the two protocols. Inpatient REE was 7,302 ± 1,272 kJ/day and outpatient REE was 7,216 ± 1,116 kJ/day (p = .448). Thirteen participants repeated the outpatient protocol and 17 repeated the inpatient protocol to assess the day-to-day variation. Reliability was assessed using the intraclass correlation coefficient and typical error. The inpatient-protocol variability was 96% with a typical error of 336.2 kJ/day. For the outpatient protocol, the intraclass correlation coefficient and typical error were 87% and 477.6 kJ/day, respectively. Results indicate no difference in REE when measured under inpatient and outpatient conditions; however, the inpatient protocol has greater reliability.


2018 ◽  
Vol 28 (3) ◽  
pp. 238-245 ◽  
Author(s):  
Lindsay B. Baker ◽  
Kelly A. Barnes ◽  
Bridget C. Sopeña ◽  
Ryan P. Nuccio ◽  
Adam J. Reimel ◽  
...  

The purpose of this study was to determine the effect of storage temperature on sodium ([Na+]), potassium ([K+]), and chloride ([Cl−]) concentrations of sweat samples analyzed 7 days after collection. Using the absorbent patch technique, 845 sweat samples were collected from 39 subjects (32 ± 7 years, 72.9 ± 10.5 kg) during exercise. On the same day as collection (PRESTORAGE), 609 samples were analyzed for [Na+], [Cl−], and [K+] by ion chromatography (IC) and 236 samples were analyzed for [Na+] using a compact ion-selective electrode (ISE). Samples were stored at one of the four conditions: −20 °C (IC, n = 138; ISE, n = 60), 8 °C (IC, n = 144; ISE, n = 59), 23 °C (IC, n = 159; ISE, n = 59), or alternating between 8 °C and 23 °C (IC, n = 168; ISE, n = 58). After 7 days in storage (POSTSTORAGE), samples were reanalyzed using the same technique as PRESTORAGE. PRESTORAGE sweat electrolyte concentrations were highly related to that of POSTSTORAGE (intraclass correlation coefficient: .945–.989, p < .001). Mean differences (95% confidence intervals) between PRESTORAGE and POSTSTORAGE were statistically, but not practically, significant for most comparisons: IC [Na+]: −0.5(0.9) to −2.1(0.9) mmol/L; IC [K+]: −0.1(0.1) to −0.2(0.1) mmol/L; IC [Cl−]: −0.4(1.4) to −1.3(1.3) mmol/L; ISE [Na+]: −2.0(1.1) to 1.3(1.1) mmol/L. Based on typical error of measurement results, 95% of the time PRESTORAGE and POSTSTORAGE sweat [Na+], [K+], and [Cl−] by IC analysis fell within ±7–9, ±0.6–0.7, and ±9–13 mmol/L, respectively, while sweat [Na+] by ISE was ±6 mmol/L. All conditions produced high reliability and acceptable levels of agreement in electrolyte concentrations of sweat samples analyzed on the day of collection versus after 7 days in storage.


2016 ◽  
Vol 11 (2) ◽  
pp. 172-175 ◽  
Author(s):  
Christopher Thomas ◽  
Thomas Dos’Santos ◽  
Paul A. Jones ◽  
Paul Comfort

Purpose:The purpose of this investigation was to determine the reliability of the 30-15 Intermittent Fitness Test (30-15IFT) in semiprofessional soccer players.Methods:Fourteen male semiprofessional soccer players performed the 30-15IFT on 2 occasions separated by 7 d. Reliability was assessed by intraclass correlation coefficient (ICC), typical error of measurement expressed as a coefficient of variation (CV), and smallest worthwhile change (SWC) to determine any significant difference between testing sessions.Results:Maximal intermittent running velocity (VIFT) demonstrated good reliability (ICC = .80) for between-sessions reliability. The CV was 2.5% for between-sessions reliability of the 30-15IFT. As the SWC (0.70 km/h) falls within the range in which the individual’s true score is likely to lie (1.0 km/h), the usefulness of the VIFT was rated as marginal. Despite the usefulness of the 30-15IFT being deemed marginal, a change in performance as small as 1.0 km/h (2 stages) in VIFT could be considered substantial or real.Conclusion:This study demonstrates that VIFT in the 30-15IFT is reliable, resulting in a reliable assessment of team-sport-specific cardiorespiratory fitness, with changes as small as 1.0 km/h (2 stages) in VIFT considered meaningful.


Author(s):  
Bahareh Nikooyeh ◽  
Nastaran Shariatzadeh ◽  
Ali Kalayi ◽  
Maliheh Zahedirad ◽  
Tirang R. Neyestani

Abstract. Some studies have reported inaccuracy of predicting basal metabolic rate (BMR) by using common equations for Asian people. Thus, this study was undertaken to develop new predictive equations for the Iranian community and also to compare their accuracy with the commonly used formulas. Anthropometric measures and thyroid function were evaluated for 267 healthy subjects (18–60 y). Indirect calorimetry (InCal) was performed only for those participants with normal thyroid function tests (n = 252). Comparison of predicted RMR (both kcal/d and kcal.kg.wt−1.d−1) using current predictive formulas and measured RMR revealed that Harris-Benedict and FAO/WHO/UNU significantly over-estimated and Mifflin-St. Jeor significantly under-estimated RMR as compared to InCal measurements. In stepwise regression analysis for developing new equations, the highest r2 (=0.89) was from a model comprising sex, height and weight. However, further analyses revealed that unlike the subjects under 30 y, the association between age and the measured RMR in subjects 30 y and plus was negative (r = −0.241, p = 0.001). As a result, two separate equations were developed for these two age groups. Over 80 percent of variations were covered by the new equations. In conclusion, there were statistical significant under- and over-estimation of RMR using common predictive equations in our subjects. Using the new equations, the accuracy of the calculated RMR increased remarkably.


Author(s):  
Habib Yarizadeh ◽  
Leila Setayesh ◽  
Caroline Roberts ◽  
Mir Saeed Yekaninejad ◽  
Khadijeh Mirzaei

Abstract. Objectives: Obesity plays an important role in the development of chronic diseases including cardiovascular disease and diabetes. A low resting metabolic rate (RMR) for a given body size and composition is a risk factor for obesity, however, there is limited evidence available regarding the association of nutrient patterns and RMR. The aim of this study was to determine the association of nutrient patterns and RMR in overweight and obese women. Study design: This cross-sectional study was conducted on 360 women who were overweight or obese. Method: Dietary intake was assessed using a semi-quantitative standard food frequency questionnaire (FFQ). Nutrient patterns were also extracted by principal components analysis (PCA). All participants were evaluated for their body composition, RMR, and blood parameters. Result: Three nutrient patterns explaining 64% of the variance in dietary nutrients consumption were identified as B-complex-mineral, antioxidant, and unsaturated fatty acid and vitamin E (USFA-vit E) respectively. Participants were categorized into two groups based on the nutrient patterns. High scores of USFA-vit E pattern was significantly associated with the increase of RMR (β = 0.13, 95% CI = 0.79 to 68.16, p = 0.04). No significant associations were found among B-complex-mineral pattern (β = −0.00, 95% CI = −49.67 to 46.03, p = 0.94) and antioxidant pattern (β = 0.03, 95% CI −41.42 to 22.59, p = 0.56) with RMR. Conclusion: Our results suggested that the “USFA-vit E” pattern (such as PUFA, oleic, linoleic, vit.E, α-tocopherol and EPA) was associated with increased RMR.


Sign in / Sign up

Export Citation Format

Share Document