2d speckle tracking
Recently Published Documents


TOTAL DOCUMENTS

312
(FIVE YEARS 119)

H-INDEX

20
(FIVE YEARS 3)

2022 ◽  
Vol 12 ◽  
Author(s):  
Huiyun Chen ◽  
Yu Gong ◽  
Fangcan Sun ◽  
Bing Han ◽  
Bingyuan Zhou ◽  
...  

Objective: This study aimed to quantitatively assess myocardial strain in preterm children aged 5 to 8 years of pregnancy complicated by severe preeclampsia (PE) by two-dimensional (2D) speckle tracking echocardiography.Method: A cohort study of 23 preterm children delivered by severe PE pregnant women from 2010 to 2012 in the First Affiliated Hospital of Soochow University was carried out. 23 preterm children from uneventful pregnancies in the same period served as controls. Myocardial functions including left ventricular longitudinal strain, radial strain, circumferential strain, and right ventricular longitudinal strain were evaluated by conventional Doppler, tissue Doppler imaging, and 2D speckle-tracking echocardiography (2D STE). All examinations were performed by an experienced ultrasonographer using the VIVID E9 (GE Healthcare) machine, according to standard techniques.Results: Children aged 5–8 years delivered from severe PE presented less weight (24.41 vs. 20.89 kg, P < 0.05), shorter height (124.1 vs 115.6 cm, P < 0.05) and faster heart rates (84 vs. 93 bpm, P < 0.05) compared to offspring of normotensive women. There were no significant differences in global left ventricular longitudinal strain, radial strain, circumferential strain, and right ventricular longitudinal strain between the children in the experimental group and the control group (P > 0.05).Conclusion: Exposure to the intrauterine environment of severe PE during the fetal period did not have a significant impact on cardiac structure in premature children at 5–8 years old, but they had a higher resting heart rate which may be associated with cardiovascular disease in the long run.


2021 ◽  
Vol 8 ◽  
Author(s):  
Ali Hosseinsabet ◽  
Roshanak Mahmoudian ◽  
Arash Jalali ◽  
Reza Mohseni-Badalabadi ◽  
Tahereh Davarpasand

Background: Normal range values of right atrial (RA) phasic function markers are essential for the identification of normal and abnormal values, comparison with reference values, and the clinical meaning of obtained values. Accordingly, we aimed to define the normal range values of RA phasic function markers obtained by 2D speckle-tracking echocardiography through a meta-analysis and determine the main sources of heterogeneity among reported values.Methods: PUBMED, SCOPUS, and EMBASE databases were searched for the following keywords: “right atrial/right atrium” and “strain/speckle/deformation” and “echocardiography.” Studies were selected that included a human healthy adult group without any cardiovascular diseases or risk factors and that were written in the English language. For the calculation of each marker of RA phasic functions, a random-effect model was used. Meta-regression was employed to define the major sources of variabilities among reported values.Results: Fifteen studies that included 2,469 healthy subjects were selected for analysis. The normal range values for RA strain and strain rate were 42.7% (95% CI, 39.4 to 45.9%) and 2.1 s−1 (95% CI, 2.0 to 2.1 s−1) during the reservoir phase, respectively, 23.6% (95% CI, 20.7 to 26.6%) and −1.9 s−1 (95% CI, −2.2 to −1.7 s−1) during the conduit phase, correspondingly, and 16.1% (95% CI, 13.6 to 18.6%) and −1.8 s−1 (95% CI, −2.0 to −1.5 s−1) during the contraction phase, respectively. The sources of heterogeneity for the normal range of these markers were the number of participants, the type of software, the method of global value calculation, the right ventricular fractional area change, the left ventricular (LV) ejection fraction, the RA volume index, sex, the heart rate, the diastolic blood pressure, the body mass index, and the body surface area.Conclusions: Using 2D speckle-tracking echocardiography, we defined normal values for RA phasic function markers and identified the sources of heterogeneity as demographic, anthropometric, hemodynamic, and echocardiography factors.Systematic Review Registration:https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42021236578, identifier: CRD42021236578.


2021 ◽  
Vol 23 (Supplement_G) ◽  
Author(s):  
Paolo Springhetti ◽  
Corinna Bergamini ◽  
Lorenzo Niro ◽  
Luisa Ferri ◽  
Giovanni Benfari ◽  
...  

Abstract Aims Trastuzumab (TZ) is widely used for his key role in HER2 positive breast cancer. However, it may have different side effects on the cardiovascular system. One of the most concerning complication is cardiotoxicity. Many studies have highlighted the importance of the screening for subclinical myocardial dysfunction using left ventricular ejection fraction (LVEF) and global longitudinal strain (GLS). However, there are few studies investigating the left atrial function in relation to the development of early cardiac damage. Aim of this study is to analyse the modification of GLS and PALS in patients undergoing therapy with TZ in a follow-up period of 12 months. The eventual fluctuation of left atrial function under chemotherapy was evaluated and the correlation between subclinical atrial disfunction and early left ventricular impairment was searched. Methods One hundred and five women affected by non-metastatic HER-2 positive breast cancer treated with TZ were enrolled. Each patient underwent a complete echocardiography every 3 months, for a total of five exams pro patient. Thirty-seven patients (35%) were excluded from the left atrial function analysis while LV function evaluation was performed in 83 patients (21%). Exclusion criteria were poor quality imaging and lack of a complete Follow-up with consequent missing data. 2D-Speckle tracking analysis was performed at baseline and at each examination using Tomtec software in order to analyse both atrial and left ventricular function. Subclinical LV disfunction was defined as a GLS reduction of ≥ 15% compared to the baseline value. Left atrial impairment was arbitrary defined as a PALS reduction of ≥ 25% compared to the initial value. Finally, trends of GLS and PALS during 12 months-Follow-up periods were analysed. Results A total of 48.9% patients developed subclinical LV dysfunction. Similarly, 48.3% patients showed a left atrial impairment. Interestingly a significant (P = 0.0001) reduction in GLS was observed during the follow-up, particularly in the first 6 months of treatment. PALS showed a similar trend with a significant decrease during the whole 12 months-follow-up (P = 0.0001) and mostly in the first 6 months. Only 11% patients showed a significant reduction of LVEF defined as an absolute reduction of LVEF >10% from baseline. Conclusions In HER 2 positive breast cancer patients treated with Trastuzumab development of left atrial impairment in not uncommon and PALS modifications follow a similar pattern to GLS variations during the treatment course, suggesting a possible cardiotoxic effect of such therapy on both atrial and left ventricular myocardium and physiology. However, the potential role of an early atrial impairment detection in predicting subsequent cardiotoxicity in terms of significant LVEF reduction still needs to be tested with further studies.


2021 ◽  
Vol 23 (Supplement_G) ◽  
Author(s):  
Martina Setti ◽  
Francesca Rizzetto ◽  
Giovanni Benfari ◽  
Beatrice Cavazza ◽  
Marta Dal Porto ◽  
...  

Abstract Aims The impact of atrial function measured by standard and advanced echocardiographic techniques is emerging in various clinical settings but remains poorly explored in patients with hypertrophic cardiomyopathy (HCM). Methods and results Consecutive patients with HCM referred to the heart failure outpatient clinic were prospectively enrolled. Complete clinical and echocardiographic evaluation was performed, including fully automated 2D speckle tracking analysis software (AutoStrain, TomTec). Atrial function was assessed by means of left atrial (LA) volume, LA diameter, a’-TDI, and global peak atrial longitudinal strain (PALS). The primary endpoint was a composite of cardiovascular (CV) events (cardiovascular death or hospitalization, new-onset atrial fibrillation, surgical myectomy, sustained ventricular tachycardia or ventricular fibrillation) during the follow-up. A total of 40 patients with confirmed HCM diagnoses and complete follow-up were included, mean age was 61 ± 14 years, 62% male, ejection fraction 64 ± 8%. LA was frequently enlarged (indexed LA volume 43 ± 14 ml/m2, LA diameter 39 ± 7 mm), and dysfunctional (a’-TDI 7.1 ± 2.2 cm/s, PALS 21 ± 7%). During a mean follow-up of 460 ± 300 days, seven patients had a CV event. Among LA parameters, septal a’-TDI seems to characterize patients with events the most (5.5 ± 2.1 vs. 7.5 ± 2.3, P = 0.03). This was confirmed in an age-adjusted survival model [HR: 0.62 (0.39–0.92), P = 0.03]. The spline curve in the Figure illustrates the relationship between a’-TDI and the age-adjusted probability of CV events; the association began at about 7 cm/s and increased steeply for lower values. Of note, the association between PALS and CV events was highly significant in younger patients (<70 years, P < 0.001). Conclusions According to our pilot study, a’-TDI can be considered a simple, feasible, and routinely available parameter of left atrial function, which can help to identify HCM patients at higher risk of CV events.


Author(s):  
Jedrzej Michalik ◽  
Alicja Dabrowska-Kugacka ◽  
Katarzyna Kosmalska ◽  
Roman Moroz ◽  
Adrian Kot ◽  
...  

We compared the effects of right ventricular (RVP; n = 26) and His bundle (HBP; n = 24) pacing in patients with atrioventricular conduction disorders and preserved LVEF. Postoperatively (1D), and after six months (6M), the patients underwent global longitudinal strain (GLS) and peak systolic dispersion (PSD) evaluation with 2D speckle-tracking echocardiography, assessment of left atrial volume index (LAVI) and QRS duration (QRSd), and sensing/pacing parameter testing. The RVP threshold was lower than the HBP threshold at 1D (0.65 ± 0.13 vs. 1.05 ± 0.20 V, p < 0.001), and then it remained stable, while the HBP threshold increased at 6M (1.05 ± 0.20 vs. 1.31 ± 0.30 V, p < 0.001). The RVP R-wave was higher than the HBP R-wave at 1D (11.52 ± 2.99 vs. 4.82 ± 1.41 mV, p < 0.001). The RVP R-wave also remained stable, while the HBP R-wave decreased at 6M (4.82 ± 1.41 vs. 4.50 ± 1.09 mV, p < 0.02). RVP QRSd was longer than HBP QRSd at 6M (145.0 ± 11.1 vs. 112.3 ± 9.3 ms, p < 0.001). The absolute value of RVP GLS decreased at 6M (16.32 ± 2.57 vs. 14.03 ± 3.78%, p < 0.001), and HBP GLS remained stable. Simultaneously, RVP PSD increased (72.53 ± 24.15 vs. 88.33 ± 30.51 ms, p < 0.001) and HBP PSD decreased (96.28 ± 33.99 vs. 84.95 ± 28.98 ms, p < 0.001) after 6 months. RVP LAVI increased (26.73 ± 5.7 vs. 28.40 ± 6.4 mL/m2, p < 0.05), while HBP LAVI decreased at 6M (30.03 ± 7.8 vs. 28.73 ± 8.7 mL/m2, p < 0.01). These results confirm that HBP does not disrupt ventricular synchrony and provides advantages over RVP.


Author(s):  
Tom Roar Omdal ◽  
Umael Khan ◽  
Cathrine Ebbing ◽  
Jörg Kessler ◽  
Henriette Odland Karlsen ◽  
...  

AbstractSpeckle tracking echocardiography is a promising method for assessment of myocardial function in fetal and neonatal hearts, but further studies are necessary to validate and optimize the settings for use in fetal cardiology. Previous studies have shown that the definition of the region of interest (ROI) affects strain values in adults. The aim of this study was to investigate how different widths of ROI influences measurements of four-chamber longitudinal systolic strain in fetuses late in pregnancy. Thirty-one singleton, healthy fetuses born to healthy mothers underwent an echocardiographic examination during gestational week 37. Speckle tracking was performed with two different settings for ROI width; the narrowest and second most narrow, provided both widths were assessed as suitable for the myocardial wall thickness of the fetus. We found an inverse correlation between the ROI width and the strain values. Four-chamber longitudinal strain changed from − 20.7 ± 3.6% to − 18.0 ± 4.4% (p < 0.001) with increasing ROI width. Further, strain decreased from the endocardium to the epicardium with multilayer measurements. Different widths of ROI influenced the strain measurements significantly in the fetal heart, comparable to what has been reported in adults. A standardization of the ROI setting could improve the interpretation, and reduce variability in fetal strain measurements.


2021 ◽  
Author(s):  
RC Rimbas ◽  
SL Magda ◽  
S Mihaila-Baldea ◽  
ML Luchian ◽  
AM Chitroceanu ◽  
...  

AIMS. None of the conventional echocardiographic parameters alone predict increased NTproBNP level and symptoms, making diagnosis of heart failure with preserved ejection fraction (HFpEF) very difficult in some cases, in resting condition. We will evaluate LA functions by 2D speckle tracking echocardiography (STE) on top of conventional parameters in HFpEF and preHF patients with diastolic dysfunction (DD), in order to establish the added value of the LA deformation parameters in the diagnosis of HFpEF. METHODS. We will enroll patients with HFpEF and compare them with asymptomatic patients with similar risk factors with DD (preHF). We will evaluate them by NTproBNP, conventional DD parameters, and STE. Global longitudinal strain (GS) was added. LA reservoir (R), conduit (C), and pump function (CT) were assessed both by volumetric and STE. 2 reservoir strain (S) derived indices were also measured, stiffness (SI) and distensibility index (DI).