contaminant removal
Recently Published Documents


TOTAL DOCUMENTS

476
(FIVE YEARS 152)

H-INDEX

39
(FIVE YEARS 10)

Water ◽  
2022 ◽  
Vol 14 (2) ◽  
pp. 137
Author(s):  
Rehab O. Abdel Rahman ◽  
Ahmed M. El-Kamash ◽  
Yung-Tse Hung

Nano-zeolite is an innovative class of materials that received recognition for its potential use in water and tertiary wastewater treatment. These applications include ion-exchange/sorption, photo-degradation, and membrane separation. The aim of this work is to summarize and analyze the current knowledge about the utilization of nano-zeolite in these applications, identify the gaps in this field, and highlight the challenges that face the wide scale applications of these materials. Within this context, an introduction to water quality, water and wastewater treatment, utilization of zeolite in contaminant removal from water was addressed and linked to its structure and the advances in zeolite preparation techniques were overviewed. To have insights into the trends of the scientific interest in this field, an in-depth analysis of the variation in annual research distribution over the last decade was performed for each application. This analysis covered the research that addressed the potential use of both zeolites and nano-zeolites. For each application, the characterization, experimental testing schemes, and theoretical analysis methodologies were overviewed. The results of the most advanced research were collected, summarized, and analyzed to allow an easy visualization and comparison of these research results. Finally, the gaps and challenges that face these applications are concluded.


2021 ◽  
pp. 253-311
Author(s):  
Francis Hopcroft ◽  
Abigail Charest

Energies ◽  
2021 ◽  
Vol 14 (23) ◽  
pp. 8167
Author(s):  
Forogh Dashtestani ◽  
Mohammad Nusheh ◽  
Vilailuck Siriwongrungson ◽  
Janjira Hongrapipat ◽  
Vlatko Materic ◽  
...  

This study investigated the effect of HCl in biomass gasification producer gas on the CO2 capture efficiency and contaminants removal efficiency by CaO-Fe2O3 based sorbent material in the calcium looping process. Experiments were conducted in a fixed bed reactor to capture CO2 from the producer gas with the combined contaminants of HCl at 200 ppmv, H2S at 230 ppmv, and NH3 at 2300 ppmv. The results show that with presence of HCl in the feeding gas, sorbent reactivity for CO2 capture and contaminants removal was enhanced. The maximum CO2 capture was achieved at carbonation temperatures of 680 °C, with efficiencies of 93%, 92%, and 87%, respectively, for three carbonation-calcination cycles. At this carbonation temperature, the average contaminant removal efficiencies were 92.7% for HCl, 99% for NH3, and 94.7% for H2S. The outlet contaminant concentrations during the calcination process were also examined which is useful for CO2 reuse. The pore structure change of the used sorbent material suggests that the HCl in the feeding gas contributes to high CO2 capture efficiency and contaminants removal simultaneously.


2021 ◽  
Vol 11 (23) ◽  
pp. 11408
Author(s):  
Ja-Young Goo ◽  
Jae-Hyun Kim ◽  
Young Jae Lee ◽  
Soonjae Lee

A non-pumping reactive well (NPRW) is a subsurface structure that prevents contaminant spread using many non-pumping wells containing reactive media. For the construction of an effective NPRW, a sufficiently small spacing between wells is an important design factor to prevent contaminant leakage. However, close well construction is not recommended because of concerns about the decreased stability of adjacent wells under field conditions. In this research, we proposed a sawtooth array of NPRW as a practical configuration to minimize well spacing while meeting stability requirements in the field. To evaluate the performance of the novel NPRW configurations, a numerical modeling was conducted considering different well diameters and well spacings and their performance was compared taking into account the number of wells and the mass of the reactive material. The comparison results showed that the sawtooth configuration was more practical than a line of wells. The performance curve of NPRWs with the saw-toothed configuration was constructed from the relationship between the contaminant removal and configuration components (diameter and spacing of the well). This can be used to predict the contaminant removal performance of NPRWs with a sawtooth array.


2021 ◽  
Vol 9 ◽  
Author(s):  
Xinwei Zhu ◽  
Yingxi Chen ◽  
Renjian Xie ◽  
Haijian Zhong ◽  
Weidong Zhao ◽  
...  

In this paper, guar gum (GG) hydrogel has been successfully prepared by adding GG and Cu2+ mixture into an alkaline medium. The formation mechanism of the hydrogel has been investigated through various techniques. Results reveal GG facilitates the formation of ultrafine copper hydroxide clusters with a diameter of ∼3 nm. Moreover, these nanoclusters bring about a rapid gelling of GG within 10 ms. The synthesized hydrogel is applied to the adsorption of heavy metal ions from wastewater. The hydrogel shows excellent removal efficiency in removing various heavy metal ions. Besides, the hydrogel derived porous carbon exhibits high specific capacitance (281 F/g at 1 A/g) and excellent rate capacity. The high contaminant removal efficiency character and excellent electrochemical performance endow GG hydrogel with potential applications in the environmental and energy storage field.


Energies ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 7570
Author(s):  
Zhonghua Zhang ◽  
Lingjie Zeng ◽  
Huixian Shi ◽  
Gukun Yang ◽  
Zhenjiang Yu ◽  
...  

The poor indoor air quality (IAQ) of severely polluted toilets is associated with increased risk of severe disease. This study aimed to evaluate the overall IAQ according to the contaminant removal efficiency, volume average concentration, and breathing zone control level. The characteristics of contaminant transmission in a non-flushing ecological toilet (NFET) were analyzed using the computational fluid dynamics (CFD) methodology, and the proposed model was further validated based on experimental measurements. Both an orthogonal experimental design and CFD were used to analyze factors such as exhaust fan position (EFP), air change rate per hour (ACH), natural vent location (NVL), and grid height (G-h). The EFP and ACH were demonstrated to be the dominant factors affecting the IAQ, whereas NVL and G-h were found to play key roles. Single-factor analysis based on the significance levels of the ACH, EFP, and NVL was conducted using the CFD methodology to define three exhaust behaviors—namely, “ineffective”, “enhanced”, and “excessive”. These results provide key insights that may be used to improve the IAQ of NFETs.


2021 ◽  
pp. 133857
Author(s):  
Ying Pan ◽  
Congying Rao ◽  
Xiaolin Tan ◽  
Yun Ling ◽  
Ayushi Singh ◽  
...  

2021 ◽  
Vol 205 ◽  
pp. 108277
Author(s):  
Mengfan Quan ◽  
Yi Wang ◽  
Yu Zhou ◽  
Kaixin Xu ◽  
Yingxue Cao ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document