interdigitated microelectrode
Recently Published Documents


TOTAL DOCUMENTS

91
(FIVE YEARS 22)

H-INDEX

17
(FIVE YEARS 3)

2021 ◽  
Vol 17 (12) ◽  
pp. 2495-2504
Author(s):  
Xiangchen Li ◽  
Subash C. B. Gopinath ◽  
Xin Peng ◽  
Jiudi Lv

An aptasensor was developed on an interdigitated microelectrode (IDME) by current-volt sensing for the diagnosis of ulcerative colitis by detecting the biomarker lipocalin-2. Higher immobilization of the anti-lipocalin-2 aptamer as a probe was achieved by using sodium dodecyl benzenesulfonate-aided zeolite particles. FESEM and FETEM observations revealed that the size of the zeolite particles was <200 nm, and they displayed a uniform distribution and spherical shape. XPS analysis attested the occurrence of Si, Al, and O groups on the zeolite particles. Zeolite particles were immobilized on IDME by a (3-aminopropyl)-trimethoxysilane amine linker, and then, the aptamer as the probe was tethered on the zeolite particles through a biotin-streptavidin strategy assisted by a bifunctional aldehyde linker. Due to the high occupancy of the aptamer and the efficient electric transfer from zeolite particles, higher changes in current can be observed upon interaction of the aptamer with lipocalin-2. The lower detection of lipocalin-2 was noted as 10 pg/mL, with a linear range from 10 pg/mL to 1 μg/mL and a linear regression equation of y=8E−07x+8E−08; R2 = 0.991. Control experiments with complementary aptamer and matrix metalloproteinase-9 indicate the specific detection of lipocalin-2. Furthermore, spiking lipocalin-2 in human serum does not interfere with the identification.


Micromachines ◽  
2021 ◽  
Vol 12 (9) ◽  
pp. 1068
Author(s):  
Javier Meléndez-Campos ◽  
Matias Vázquez-Piñón ◽  
Sergio Camacho-Leon

Dielectric characteristics are useful to determine crucial properties of liquids and to differentiate between liquid samples with similar physical characteristics. Liquid recognition has found applications in a broad variety of fields, including healthcare, food science, and quality inspection, among others. This work demonstrates the fabrication, instrumentation, and functionality of a portable wireless sensor node for the permittivity measurement of liquids that require characterization and differentiation. The node incorporates an interdigitated microelectrode array as a transducer and a microcontroller unit with radio communication electronics for data processing and transmission, which enable a wide variety of stand-alone applications. A laser-ablation-based microfabrication technique is applied to fabricate the microelectromechanical systems (MEMS) transducer on a printed circuit board (PCB) substrate. The surface of the transducer is covered with a thin layer of SU-8 polymer by spin coating, which prevents it from direct contact with the Cu electrodes and the liquid sample. This helps to enhance durability, avoid electrode corrosion and contamination of the liquid sample, and to prevent undesirable electrochemical reactions to arise. The transducer’s impedance was modeled as a Randles cell, having resistive and reactive components determined analytically using a square wave as stimuli, and a resistor as a current-to-voltage converter. To characterize the node sensitivity under different conditions, three different transducer designs were fabricated and tested for four different fluids, i.e., air, isopropanol, glycerin, and distilled water—achieving a sensitivity of 1.6965 +/− 0.2028 εr/pF. The use of laser ablation allowed the reduction of the transducer footprint while maintaining its sensitivity within an adequate value for the targeted applications.


Materials ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 3930
Author(s):  
Liuchuan Guo ◽  
Sihan Wang ◽  
Zhiwei He ◽  
Jing Zhang ◽  
Xiaoli Zhu ◽  
...  

Difenacoum (DIF) is one of the most widely used anticoagulant rodenticides. However, accidental or intentional ingestion of DIF seriously threatens humans and other non-target species. Therefore, a rapid and sensitive detection method to quantify DIF is urgently needed. In this study, one anti-DIF nanobody (Nb) was assembled on the surface of a gold interdigitated microelectrode (IDME) using an Au–S bond to fabricate a bioimpedance sensor. To improve the immobilization amount of Nbs on the electrode, a polycrystalline gold IDME was prepared to provide a larger surface and better biocompatibility. Thus, a novel and ultrasensitive bioimpedance sensor based on electrochemical impedance spectroscopy (EIS) was designed for the determination of DIF, and it displayed good reproducibility and stability in human serum. The proposed bioimpedance sensor displayed a wide working range, between 0.1–1000 pg/mL, with a limit of detection (LOD) of 0.1 pg/mL of DIF. This method exhibited excellent performance, good sensitivity, and reproducibility and achieved the highest sensitivity of all currently existing methods used to quantify DIF. The highly sensitive DIF detection of this proposed bioimpedance sensor indicates its potential as an efficacious approach for DIF monitoring in human serum with high accuracy and precision.


2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Jian Zhang ◽  
Xin Fang ◽  
Yu Mao ◽  
Haochen Qi ◽  
Jayne Wu ◽  
...  

AbstractDue to the friendly temperature for virus survival, SARS-CoV-2 is frequently found in cold-chain foods, posing a serious threat to public health. Utilizing an interdigitated microelectrode chip modified with an antibody probe and integrating dielectrophoresis enrichment with interfacial capacitance sensing, a strategy is presented for the detection of trace level spike-protein from SARS-CoV-2. It achieves a limit of detection as low as 2.29 × 10−6 ng/mL in 20 s, with a wide linear range of 10−5–10−1 ng/mL and a selectivity of 234:1. The cost for a single test can be controlled to ~1 dollar. This strategy provides a competitive solution for real-time, sensitive, selective, and large-scale application in cold-chain food quarantine.


2021 ◽  
Vol 188 (6) ◽  
Author(s):  
Guangjun Yan ◽  
Qingchun Li ◽  
Xingyu Hong ◽  
Subash C. B. Gopinath ◽  
Periasamy Anbu ◽  
...  

2021 ◽  
Vol 4 (1) ◽  
pp. 40
Author(s):  
Javier Meléndez-Campos ◽  
Matias Vázquez-Piñón ◽  
Sergio Camacho-Leon

Dielectric characteristics are useful to determine crucial properties of liquids and to differentiate between liquid samples with similar physical characteristics. Liquid recognition has found applications in a broad variety of fields, including healthcare, food science, and quality inspection, among others. This work demonstrates the fabrication, instrumentation, and functionality of a portable wireless sensor node for permittivity measurement of liquids that require characterization and differentiation. The node incorporates an interdigitated microelectrode array as transducer, and a microcontroller unit with radio communication electronics for data processing and transmission, which enables a wide variety of stand-alone applications. A laser-ablation-based microfabrication technique is applied to fabricate the microelectromechanical systems (MEMS) transducer on a printed circuit board (PCB) substrate. The surface of the transducer is covered with a thin layer of SU-8 polymer by spin coating, which prevents direct contact between the Cu electrodes and the liquid sample. This helps to enhance durability, avoid electrode corrosion and contamination of the liquid sample, and to prevent undesirable electrochemical reactions from arising. The transducer’s impedance was modelled as a Randles cell, having resistive and reactive components determined analytically, using a square wave as stimuli and a resistor as a current-to-voltage converter. To characterize the node sensitivity under different conditions, three different transducer designs were fabricated and tested for four different fluids—i.e., air, isopropanol, glycerin, and distilled water—achieving a sensitivity of 1.6965 +/− 0.2028 εr/pF. The use of laser ablation allowed the reduction of the transducer footprint while maintaining its sensitivity within an adequate value for the targeted applications.


2020 ◽  
Author(s):  
Haochen Qi ◽  
Jian Zhang ◽  
Jayne Wu ◽  
Xin Fang ◽  
Fangshuo You ◽  
...  

<div>Utilizing an interdigitated microelectrode chip modified with an antibody probe, and integrating dielectrophoresis enrichment with interfacial capacitance sensing, a real-time immunosensor is presented for detection of trace level biomarkers from virus. <br></div>


2020 ◽  
Author(s):  
Haochen Qi ◽  
Jian Zhang ◽  
Jayne Wu ◽  
Xin Fang ◽  
Fangshuo You ◽  
...  

<div>Utilizing an interdigitated microelectrode chip modified with an antibody probe, and integrating dielectrophoresis enrichment with interfacial capacitance sensing, a real-time immunosensor is presented for detection of trace level biomarkers from virus. <br></div>


Sign in / Sign up

Export Citation Format

Share Document