scholarly journals Electromagnetic navigation reduces radiation exposure for retrograde drilling in osteochondrosis dissecans of the talus

2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Oliver D Jungesblut ◽  
Josephine Berger-Groch ◽  
Michael Hoffmann ◽  
Malte Schroeder ◽  
Kara L. Krajewski ◽  
...  

Abstract Background Retrograde drilling in osteochondrosis dissecans (OCD) is a widely used surgical intervention. A radiation-free electromagnetic navigation system (ENS)-based method was compared with the standard freehand fluoroscopic (SFF) method regarding clinical applicability. Methods We performed a clinical cohort study at a department of Orthopaedics in a Level 1 children’s hospital with 40 patients (20 SFF and 20 ENS). Retrograde drilling of the talar dome was used in patients with unstable medial OCD (MRI stage 2 according to Hepple’s revised classification; stage 2 according to the International Cartilage Repair Society). The outcome measurements were: (a) Intraoperative fluoroscopy exposure and length of surgery and (b) Postoperative serial follow-up MRIs every 6 months. Results 22 female and 18 male patients aged 13.8 ± 1.6 years (range: 11–17 years) were included. Using the ENS technique, length of surgery was significantly reduced to 20.2 ± 6.4 min compared to 36.1 ± 11.8 min (p < 0.01) for the SFF technique. The average x-ray radiation time for the SFF technique was 23.5 ± 13.5 sec and 1.9 ± 1.7 sec for the ENS technique (p < 0.01). Radiation exposure was significantly reduced from 44.6 ± 19.7 mSv (SFF technique) to 5.6 ± 2.8 mSv (ENS technique) (p < 0.01). Intraoperative perforation of cartilage occurred once in the SFF group. Correct placement of the drilling channel was verified in all patients on follow-up MRI after six months and a timely healing was seen after two years. Conclusions The ENS method provides for a significant reduction in length of surgery and radiation exposure. ENS was without intraoperative cartilage perforation. The clinical and radiological follow-up parameters are comparable for SFF- and ENS-guided retrograde drilling. Trial registration WF – 085/20, 05/2020 “retrospectively registered” https://www.aerztekammer-hamburg.org/ethik_kommission.html.

2020 ◽  
Author(s):  
Josephine Berger-Groch ◽  
Oliver D Jungesblut ◽  
Michael Hoffmann ◽  
Malte Schroeder ◽  
Kara L Krajewski ◽  
...  

Abstract Background: Retrograde drilling in osteochondrosis dissecans (OCD) is a widely used surgical intervention. A radiation-free electromagnetic navigation system (ENS)-based method was compared with the standard freehand fluoroscopic (SFF) method regarding clinical applicability.Methods: We performed a clinical cohort study at a department of Orthopaedics in a Level 1 children’s hospital with 40 patients (20 SFF and 20 ENS). Retrograde drilling of the talar dome was used in patients with unstable medial OCD (MRI stage 2 according to Hepple’s revised classification; stage 2 according to the International Cartilage Repair Society). The outcome measurements were: a) Intraoperative fluoroscopy exposure and length of surgery and b) Postoperative serial follow-up MRIs every 6 months.Results: 22 female and 18 male patients aged 13.8 ± 1.6 years (range: 11-17 years) were included. Using the ENS technique, length of surgery was significantly reduced to 20.2 ± 6.4 min compared to 36.1 ± 11.8 min (p<0.01) for the SFF technique. The average x-ray radiation time for the SFF technique was 23.5 ± 13.5 sec and 1.9 ± 1.7 sec for the ENS technique (p<0.01). Radiation exposure was significantly reduced from 44.6 ± 19.7 mSv (SFF technique) to 5.6± 2.8 mSv (ENS technique) (p<0.01). Intraoperative perforation of cartilage occurred once in the SFF group. Correct placement of the drilling channel was verified in all patients on follow-up MRI after six months and a timely healing was seen after two years. No differences were detected on follow-up MRI between the two methods.Conclusions: The ENS method provides for a significant reduction in length of surgery and radiation exposure. ENS was without intraoperative cartilage perforation. The clinical and radiological follow-up parameters are comparable for SFF- and ENS-guided retrograde drilling.Trial registration: WF – 085/20, 05/2020 “retrospectively registered”


2009 ◽  
Vol 27 (15_suppl) ◽  
pp. 6017-6017
Author(s):  
P. M. Specenier ◽  
Y. Lalami ◽  
J. Vermorken ◽  
D. Lacombe ◽  
I. El-Hariry ◽  
...  

6017 Background: CRT is considered a standard approach for LA-LxHxSCC. TPF IC regimen seems to improve outcome in locally advanced head and neck SCC. The addition of LAP was investigated in combination with a sequential therapeutic approach (IC→ CRT). Methods: Eligible tumors were SCCHN: T3-T4 larynx (Lx), T2-T4 hypopharynx (Hx) N0–3 M0. The objective of this trial is to determine MTD, DLT and recommended dose of LAP when administered with TPF IC (docetaxel (T) 75mg/m2 (60 mg/m2 for the first cycle) d1, CDDP 75mg/m2 d1, 5FU 750mg/m2/d continuous infusion d1-d5 q3weeks) followed by CRT (weekly carboplatin AUC 1.5 and RT 70Gy in 7 weeks; 2Gy/fx). LAP is administered concomitantly with IC (escalating dose 500–1500mg po daily) and during CRT (1,500 mg daily). Results: Seven male patients were included; tumor sites: LX (n = 3) / Hx: (n = 4), median age 59 years (range: 47–79), WHO PS 0–1, no severe or uncontrolled comorbidity. Three pts were included in the first cohort, at dose level 1 (LAP 500 mg daily plus TPF IC). Renal toxicity was observed among these 3 pts (grade 4 [n = 1], grade 2 [n=1] and grade 1 [n=1]), with 1 DLT, leading to treatment interruption in this group. This nephrotoxicity was reversible after stopping lapatinib and hydration of the patients. As LAP plus cisplatinum plus RT was feasible in another study, a second cohort was conducted in 4 pts, receiving LAP at the same dosage, and docetaxel (T) was only introduced from cycle 2 of IC to see what is the role of T in the observed side effect. Two DLTs were observed among this second cohort of subjects: one pt presented a grade 2 renal toxicity, grade 3 diarrhea and dehydration and a second pt presented a grade 3 anorexia and grade 3 stomatitis. Based on the occurrence of 3 DLTs at the first dose level of LAP, patient recruitment was closed. Despite these safety issues, all patients recovered and were treated off-study. They will receive follow-up as foreseen by the protocol. Conclusions: These data suggest that LAP should not be combined with TPF IC regimen for LA-LxHxSCC due to prohibited toxicity. [Table: see text]


2018 ◽  
Vol 53 (3) ◽  
pp. 226
Author(s):  
Jae Young Cho ◽  
Seung Hyeon Jeung ◽  
Sung Min Hong ◽  
Jeung Tak Suh ◽  
Yoon Young Choi ◽  
...  

2020 ◽  
Vol 19 (2) ◽  
pp. 64-68
Author(s):  
Mrinmoy Biswas ◽  
Sudip Das Gupta ◽  
Mohammed Mizanur Rahman ◽  
Sharif Mohammad Wasimuddin

Objective: To assess the success of BMG urethroplasty in long segment anterior urethral stricture. Method: From January 2014 to December 2015, twenty male patients with long anterior segment urethral stricture were managed by BMG urethroplasty. After voiding trial they were followed up at 3 month with Uroflowmetry, RGU & MCU and PVR measurement by USG. Patients were further followed up with Uroflowmetry and PVR at 6 months interval.Successful outcome was defined as normal voiding with a maximum flow rate >15ml /sec and PVR<50 ml with consideration of maximum one attempt of OIU after catheter removal. Results: Mean stricture length was 5.2 cm (range 3-9 cm) and mean follow-up was 15.55 months (range 6-23 months). Only two patients developed stricture at proximal anastomotic site during follow-up. One of them voided normally after single attempt of OIU. Other one required second attempt of OIU and was considered as failure (5%). Conclusion: BMG urethroplasty is a simple technique with good surgical outcome. Bangladesh Journal of Urology, Vol. 19, No. 2, July 2016 p.64-68


Author(s):  
Elizabeth Vogel ◽  
Thomas Leaver ◽  
Fiona Wall ◽  
Ben Johnson ◽  
Michael Uglow ◽  
...  

Abstract Objective There are no data on the effect of X-Ray irradiation to the vulnerable pelvic organs of babies during DDH follow-up. This study aims to calculate, for the first time, the radiation exposure to infants during follow-up for DDH harness treatment, and thus quantify the lifetime risk of malignancy. Methods Patients who had completed 5 years’ follow-up following successful Pavlik harness treatment were identified from the hospital DDH database. The radiation dose was extracted from the Computerised Radiology Information System database for every radiograph of every patient. The effective dose (ED) was calculated using conversion coefficients for age, sex and body region irradiated. Cumulative ED was compared to Health Protection Agency standards to calculate lifetime risk of malignancy from the radiographs. Results All radiographs of 40 infants, successfully treated in Pavlik harness for DDH, were assessed. The mean number of AP pelvis radiographs was 7.00 (range: 6–9, mode: 7). The mean cumulative ED was 0.25 mSv (Range: 0.11–0.46, SD: 0.07). This is far lower than the annual ‘safe’ limit for healthcare workers of 20 mSv and is categorised as “Very Low Risk”. Conclusion Clinicians involved in the treatment DDH can be re-assured that the cumulative radiation exposure from pelvic radiographs following Pavlik harness treatment is “Very Low Risk”. Whilst being mindful of any radiation exposure in children, this study provides a scientific answer that help addresses parental concerns.


2021 ◽  
Vol 16 (01) ◽  
pp. e46-e50
Author(s):  
Carmen Joanna González Lemus ◽  
Fernando Xavier Romero Prieto

Abstract Objective This study aimed to estimate the prevalence of brachial plexus injuries and to characterize clinically and epidemiologically patients with brachial plexus injury. Materials and Methods In this cross-sectional descriptive study, 2,923 medical records of patients aged 1 to 64 years who presented at outpatient peripheral nerve unit of the Orthopedic Surgery Department of Hospital Roosevelt, Guatemala, from January 2017 to December 2017, were prospectively analyzed to identify the prevalence and factors associated with brachial plexus injuries. Results The prevalence rate of brachial plexus injuries in patients was 5.74%. This injury is more common in men (90.5%) aged 24 to 64 years. Brachial plexus injuries occurred secondary to motorcycle accident in 72% of the cases, with the majority affecting the dominant upper extremity. In addition, 64.28% of the patients took 1 to 6 months to seek consultation, whereas only 16.07% requested medical assistance <1 month from the onset of symptoms, and this result was associated with early diagnosis and adequate recovery during follow-up. Furthermore, 66.67% presented upper brachial plexus injury with no associated fractures or vascular injury, manifesting distress while performing daily activities that required hand, arm, and elbow movements. Conclusion The risk of suffering BPIs in Guatemala increases in economically active male patients that use motorcycles as main mode of transportation. Patients should consult immediately after injury onset to optimize management results. For this reason, hospitals must develop specialized clinical guidelines to speed up the identification and treatment of BPI injuries.


2019 ◽  
Vol 128 (10) ◽  
pp. 894-902 ◽  
Author(s):  
Julia Kristin ◽  
Manuel Burggraf ◽  
Dirk Mucha ◽  
Christoph Malolepszy ◽  
Silvan Anderssohn ◽  
...  

Objective: Navigation systems create a connection between imaging data and intraoperative situs, allowing the surgeon to consistently determine the location of instruments and patient anatomy during the surgical procedure. The best results regarding the target registration error (measurement uncertainty) are normally demonstrated using fiducials. This study aimed at investigating a new registration strategy for an electromagnetic navigation device. Methods: For evaluation of an electromagnetic navigation system and comparison of registration with screw markers and automatic registration, we are calculating the target registration error in the region of the paranasal sinuses/anterior and lateral skull base with the use of an electromagnetic navigation system and intraoperative digital volume tomography (cone-beam computed tomography). We carried out 10 registrations on a head model (total n = 150 measurements) and 10 registrations on 4 temporal bone specimens (total n = 160 measurements). Results: All in all, the automatic registration was easy to perform. For the models that were used, a significant difference between an automatic registration and the registration on fiducials was evident for just a limited number of screws. Furthermore, the observed differences varied in terms of the preferential registration procedure. Conclusion: The automatic registration strategy seems to be an alternative to the established methods in artificial and cadaver models of intraoperative scenarios. Using intraoperative imaging, there is an option to resort to this kind of registration as needed.


2017 ◽  
Vol 84 (4) ◽  
pp. 263-266 ◽  
Author(s):  
Christophe Llorens ◽  
Tobias Pottek

Study Design This is a retrospective, non-randomised study. Objectives The aim of this study was to evaluate safety and efficacy of artificial urinary sphincter ZSI 375 inserted in male patients with stress urinary incontinence (SUI). Methods Between May 2009 and January 2017, 45 men with SUI underwent ZSI 375 device insertion. Operations were performed in two French centres by one surgeon. Complications and pad used to manage continence were recorded. Results From May 2009 to January 2012, 45 patients with a mean age of 70.42 years underwent placement of the ZSI 375 device in France. The most common cause for incontinence was radical prostatectomy (RP, 33/45 ­patients, 73.33%). The minimal period of incontinence was 6 months. Twenty-seven out of 45 patients (60.00%) had a severe incontinence (at least four pads per day), 13 patients (28.89%) had moderate incontinence (three pads per day) and five patients (11.11%) had two pads per day. With a long follow-up, the ZSI 375 device was considered to be successful in 73.33% patients after 5 years (60 months) and 72% of patients after 7 years (84 months). The infection rate was 2.2 % affecting one in 45 patients. Six out of 45 patients presented a urethral erosion (13.33%). Mechanical failure with a revision occurred in three patients (6.67%). Conclusions The ZSI 375 device is a safe and effective device to treat severe SUI in men.


Sign in / Sign up

Export Citation Format

Share Document