fire initiation
Recently Published Documents


TOTAL DOCUMENTS

40
(FIVE YEARS 4)

H-INDEX

12
(FIVE YEARS 1)

2020 ◽  
pp. 105-110
Author(s):  
T. Todd Lindley ◽  
Alexander B. Zwink ◽  
Chad M. Gravelle ◽  
Christopher C. Schmidt ◽  
Cynthia K. Palmer ◽  
...  

Corroboration of Geostationary Operational Environmental Satellite-17 (GOES-17) wildland fire detection capabilities occurred during the 24 October 2019 (evening of 23 October LST) ignition of the Kincade Fire in northern California. Post-analysis of remote sensing data compared to observations by the ALERTWildfire fire surveillance video system suggests that the emerging Kincade Fire hotspot was visually evident in GOES17 shortwave infrared imagery 52 s after the initial near-infrared heat source detected by the ground-based camera network. GOES-17 Advanced Baseline Imager Fire Detection Characteristic algorithms registered the fire 5 min after ignition. These observations represent the first documented comparative dataset between fire initiation and satellite detection, and thus provide context for GOES-16/17 wildland fire detections.


2019 ◽  
pp. 1 ◽  
Author(s):  
L. A. Fidalgo-González ◽  
S. Arellano-Pérez ◽  
J. G. Álvarez-González ◽  
F. Castedo-Dorado ◽  
A. D. Ruiz-González ◽  
...  

<p>Canopy fuel load, canopy bulk density and canopy base height are structural variables used to predict crown fire initiation and spread. Direct measurement of these variables is not functional, and they are usually estimated indirectly by modelling. Advances in fire behaviour modelling require accurate and landscape scale estimates of the complete vertical distribution of canopy fuels. The goal of the present study is to model the vertical profile of available canopy fuels in Scots pine stands by using data from the Spanish national forest inventory and low-density LiDAR data (0.5 first returns  m<sup>–2</sup>) provided by Spanish PNOA project (Plan Nacional de Ortofotografía Aérea). In a first step, the vertical distribution of the canopy fuel load was modelled using the Weibull probability density function. In a second step, a system of models was fitted to relate the canopy variables to Lidar-derived metrics. Models were fitted simultaneously to compensate the effects of the inherent cross-model correlation between errors. Heteroscedasticity was also analyzed, but correction in the fitting process was not necessary. The estimated canopy fuel load profiles from LiDAR-derived metrics explained 41% of the variation in canopy fuel load in the analysed plots. The proposed models can be used to assess the effectiveness of different forest management alternatives for reducing crown fire hazard.</p>


2018 ◽  
Vol 209 ◽  
pp. 00021
Author(s):  
Valeriy Perminov ◽  
Victoria Marzaeva

The protection of buildings and structures in a community from destruction by forest fires is a very important concern. This paper addresses the development of a mathematical model for fires in the wildland-urban intermix. The forest fire is a very complicated phenomenon. At present, fire services can forecast the danger rating of, or the specific weather elements relating to, forest fire. There is need to understand and predict forest fire initiation, behavior and impact of fire on the buildings and constructions. This paper’s purposes are the improvement of knowledge on the fundamental physical mechanisms that control forest fire behavior. The mathematical modeling of forest fires actions on buildings and structures has been carried out to study the effects of fire intensity and wind speed on possibility of ignition of buildings.


2017 ◽  
Vol 26 (2) ◽  
pp. e02S ◽  
Author(s):  
Francisco Rodríguez y Silva ◽  
Mercedes Guijarro ◽  
Javier Madrigal ◽  
Enrique Jiménez ◽  
Juan R. Molina ◽  
...  

Aims of study: To conduct the first full-scale crown fire experiment carried out in a Mediterranean conifer stand in Spain; to use different data sources to assess crown fire initiation and spread models, and to evaluate the role of convection in crown fire initiation.Area of study: The Sierra Morena mountains (Coordinates ETRS89 30N: X: 284793-285038; Y: 4218650-4218766), southern Spain, and the outdoor facilities of the Lourizán Forest Research Centre, northwestern Spain.Material and methods: The full-scale crown fire experiment was conducted in a young Pinus pinea stand. Field data were compared with data predicted using the most used crown fire spread models. A small-scale experiment was developed with Pinus pinaster trees to evaluate the role of convection in crown fire initiation. Mass loss calorimeter tests were conducted with P. pinea needles to estimate residence time of the flame, which was used to validate the crown fire spread model.Main results: The commonly used crown fire models underestimated the crown fire spread rate observed in the full-scale experiment, but the proposed new integrated approach yielded better fits. Without wind-forced convection, tree crowns did not ignite until flames from an intense surface fire contacted tree foliage. Bench-scale tests based on radiation heat flux therefore offer a limited insight to full-scale phenomena.Research highlights: Existing crown fire behaviour models may underestimate the rate of spread of crown fires in many Mediterranean ecosystems. New bench-scale methods based on flame buoyancy and more crown field experiments allowing detailed measurements of fire behaviour are needed.


2017 ◽  
Vol 26 (10) ◽  
pp. 852 ◽  
Author(s):  
Kellen N. Nelson ◽  
Monica G. Turner ◽  
William H. Romme ◽  
Daniel B. Tinker

Early-seral forests are expanding throughout western North America as fire frequency and annual area burned increase, yet fire behaviour in young postfire forests is poorly understood. We simulated fire behaviour in 24-year-old lodgepole pine (Pinus contorta var. latifolia) stands in Yellowstone National Park, Wyoming, United States using operational models parameterised with empirical fuel characteristics, 50–99% fuel moisture conditions, and 1–60kmhr−1 open winds to address two questions: [1] How does fireline intensity, and crown fire initiation and spread vary among young, lodgepole pine stands? [2] What are the contributions of fuels, moisture and wind on fire behaviour? Sensitivity analysis indicated the greatest contributors to output variance were stand structure mediated wind attenuation, shrub fuel loads and 1000-h fuel moisture for fireline intensity; crown base height for crown fire initiation; and crown bulk density and 1-h fuel moisture for crown fire spread. Simulation results predicted crown fire (e.g. passive, conditional or active types) in over 90% of stands at 50th percentile moisture conditions and wind speeds greater than 3kmhr−1. We conclude that dense canopy characteristics heighten crown fire potential in young, postfire lodgepole pine forests even under less than extreme wind and fuel moisture conditions.


2017 ◽  
Vol 26 (4) ◽  
pp. 345 ◽  
Author(s):  
Martin E. Alexander ◽  
Miguel G. Cruz

This state-of-knowledge review examines some of the underlying assumptions and limitations associated with the inter-relationships among four widely used descriptors of surface fire behaviour and post-fire impacts in wildland fire science and management, namely Byram's fireline intensity, flame length, stem-bark char height and crown scorch height. More specifically, the following topical areas are critically examined based on a comprehensive review of the pertinent literature: (i) estimating fireline intensity from flame length; (ii) substituting flame length for fireline intensity in Van Wagner's crown fire initiation model; (iii) the validity of linkages between the Rothermel surface fire behaviour and Van Wagner's crown scorch height models; (iv) estimating flame height from post-fire observations of stem-bark char height; and (v) estimating fireline intensity from post-fire observations of crown scorch height. There has been an overwhelming tendency within the wildland fire community to regard Byram's flame length–fireline intensity and Van Wagner's crown scorch height–fireline intensity models as universal in nature. However, research has subsequently shown that such linkages among fire behaviour and post-fire impact characteristics are in fact strongly influenced by fuelbed structure, thereby necessitating consideration of fuel complex specific-type models of such relationships.


Author(s):  
Frank Gareau ◽  
Alex Tatarov

Fibreglass reinforced plastic pipe (FRP) is the second most common type of pipe in the Canadian oil and gas industry, based on installed length. Industry methods to define risks and prevent failures are difficult because industry is still learning how these types of materials fail. Current industry failure records indicate that the failure rates for some of these materials are higher than steel failure rates. Unique details related to a specific FRP failure will be discussed in this paper. This failure occurred on an 8-inch OD FRP pipeline at the bottom of a riser. The failure resulted in a spill and a fire. The reasons for failure and fire initiation were analysed separately. The failure was a result of a combination of several types of stresses and material degradation. Both static and dynamic stresses contributed to the failure. • Ground settling resulted in high static bending stress of the last section of the pipeline connected to the riser elbow supported by the anchor. • The failure was in the last connection of the pipeline. Static tie-in stresses could have contributed to the failure. • Static stresses were evaluated using Finite Element Analysis (FEA) approach and found to be insufficient for the failure. • Dynamic stresses contributed to the failure. The failure happened soon after a power outage, when numerous wells were restarted, and several fluid surges may have occurred. • Material degradation associated with a specific orientation of glass fibres at the connection pup contributed to the failure. The failure sequence was established and different modes of fire initiation were analysed.


Sign in / Sign up

Export Citation Format

Share Document