scholarly journals A New Sample Preparation Method for Isotope Ratio Mass Spectrometry of2H-Enriched Samples Generated by the Doubly Labeled Water Method

1995 ◽  
Vol 3 ◽  
pp. 73-74 ◽  
Author(s):  
Gregory G. Dolnikowski
2018 ◽  
Vol 314 (2) ◽  
pp. E124-E130 ◽  
Author(s):  
Edward L. Melanson ◽  
Tracy Swibas ◽  
Wendy M. Kohrt ◽  
Vicki A. Catenacci ◽  
Seth A. Creasy ◽  
...  

When the doubly labeled water (DLW) method is used to measure total daily energy expenditure (TDEE), isotope measurements are typically performed using isotope ratio mass spectrometry (IRMS). New technologies, such as off-axis integrated cavity output spectroscopy (OA-ICOS) provide comparable isotopic measurements of standard waters and human urine samples, but the accuracy of carbon dioxide production (V̇co2) determined with OA-ICOS has not been demonstrated. We compared simultaneous measurement V̇co2 obtained using whole-room indirect calorimetry (IC) with DLW-based measurements from IRMS and OA-ICOS. Seventeen subjects (10 female; 22 to 63 yr) were studied for 7 consecutive days in the IC. Subjects consumed a dose of 0.25 g H218O (98% APE) and 0.14 g 2H2O (99.8% APE) per kilogram of total body water, and urine samples were obtained on days 1 and 8 to measure average daily V̇co2 using OA-ICOS and IRMS. V̇co2 was calculated using both the plateau and intercept methods. There were no differences in V̇co2 measured by OA-ICOS or IRMS compared with IC when the plateau method was used. When the intercept method was used, V̇co2 using OA-ICOS did not differ from IC, but V̇co2 measured using IRMS was significantly lower than IC. Accuracy (~1–5%), precision (~8%), intraclass correlation coefficients ( R = 0.87–90), and root mean squared error (30–40 liters/day) of V̇co2 measured by OA-ICOS and IRMS were similar. Both OA-ICOS and IRMS produced measurements of V̇co2 with comparable accuracy and precision compared with IC.


2010 ◽  
Vol 75 (6) ◽  
pp. 803-812 ◽  
Author(s):  
Snezana Kravic ◽  
Zvonimir Suturovic ◽  
Jaroslava Svarc-Gajic ◽  
Zorica Stojanovic ◽  
Mira Pucarevic

A sample preparation method based on the simultaneous microwave-assisted extraction-esterification (SMAEE) was developed for the determination of the fatty acid composition of foodstuffs by gas chromatography-mass spectrometry. The proposed sample preparation method was validated by comparison with the reference Soxhlet extraction method followed by derivatisation by ester formation and the same determination step. The fatty acid compositions and the extraction efficiencies obtained using the proposed SMAEE method and the reference method were statistically similar. The results showed that compared to the conventional method, the SMAEE method offered the advantages of short sample preparation time, low consumption of expensive organic solvents and lower energy consumption. This good agreement between results provided by both the SMAEE and the reference method demonstrates the usefulness of the former as a routine method for the treatment of food samples prior to trans fatty analysis.


The Analyst ◽  
2019 ◽  
Vol 144 (21) ◽  
pp. 6371-6381 ◽  
Author(s):  
Rachel E. Heap ◽  
Anna Segarra-Fas ◽  
Alasdair P. Blain ◽  
Greg M. Findlay ◽  
Matthias Trost

A fast and robust sample preparation method for MALDI TOF MS analysis of whole mammalian cells and phenotypic profiling of mESCs.