A polymer thin-film technique to study the micromorphology of core/shell latexes

1987 ◽  
Vol 25 (9) ◽  
pp. 2595-2603
Author(s):  
O. L. Shaffer ◽  
V. L. Dimonie ◽  
M. S. El-Aasser ◽  
J. W. Vanderhoff
Author(s):  
O.L. Shaffer ◽  
V. Dimonie ◽  
M.S. El-Aasser ◽  
J.W. Vanderhoff

There is a great deal of interest in the morphology of polymers. Polymer systems such as physical blends, copolymers and latexes of the core-shell type have become increasingly important in “designing properties”. of the final polymer. Phase separation examination is an excellent method of studying the morphology in these polymer systems.Normally phase separation in polymers has been studied by TEM. The standard sample preparation is to embed the solid polymer in epoxy and then microtome. Microtoming can create artifacts such as distortion due to the knife, cutting difficulty with a rubber phase and possible polymer-epoxy interaction. Because of the above mentioned problems a thin film technique has been developed to circumvent the microtoming procedure. A ruthenium tetrox-ide (RUO4) stain was also used to increase contrast.


2003 ◽  
Vol 771 ◽  
Author(s):  
Michael C. Hamilton ◽  
Sandrine Martin ◽  
Jerzy Kanicki

AbstractWe have investigated the effects of white-light illumination on the electrical performance of organic polymer thin-film transistors (OP-TFTs). The OFF-state drain current is significantly increased, while the drain current in the strong accumulation regime is relatively unaffected. At the same time, the threshold voltage is decreased and the subthreshold slope is increased, while the field-effect mobility of the charge carriers is not affected. The observed effects are explained in terms of the photogeneration of free charge carriers in the channel region due to the absorbed photons.


Author(s):  
Mohamed H. Abdel‐Aziz ◽  
Mohammed Zwawi ◽  
Ahmed F. Al‐Hossainy ◽  
Mohamed Sh. Zoromba

Water ◽  
2021 ◽  
Vol 13 (11) ◽  
pp. 1464
Author(s):  
Leon Katona ◽  
Yvonne Vadeboncoeur ◽  
Christopher T. Nietch ◽  
Katie Hossler

Recent studies suggest that photophysiological parameters for intact substrates with depth (e.g., periphytic biofilms, microphytobenthos) are overestimated by pulse-amplitude modulated (PAM) fluorometry. This overestimation results from depth-integration effects, following the activation of deeper photosynthesizing layers by an attenuated light signal. To mitigate this error, we propose a novel slide-based thin-film technique in which fluorescence is measured on a vertically representative subsample of the biofilm, spread evenly on a microscope slide. We compared bias and precision for photosynthetic parameters estimated through conventional PAM fluorometry on intact biofilms and through our novel slide-based technique, both theoretically and empirically. Numerical simulations confirmed the consistent overestimation of key parameters for intact biofilms, with relative errors up to 145%, compared to, at most, 52% on thin films. Paired empirical observations likewise demonstrated that estimates based on intact biofilms were consistently higher (up to 248%, p<0.001) than estimates from thin films. Numerical simulation suggested greater precision with the slide-based technique for homogeneous biofilms, but potentially less precision for heterogeneous biofilms with improper subsampling. Our empirical comparison, however, demonstrated some improvement in precision with the slide-based technique (e.g., the coefficient of variation for the maximum electron transport rate was reduced 30%, p=0.009). We recommend the use of the slide-based technique, particularly for biofilms that are thick or have small light attenuation coefficients. Care should be taken, however, to obtain vertically representative subsamples of the biofilm for measurement.


Polymers ◽  
2020 ◽  
Vol 12 (9) ◽  
pp. 2133
Author(s):  
Xue Li ◽  
Jun-Yi Sun ◽  
Bin-Bin Shi ◽  
Zhi-Hang Zhao ◽  
Xiao-Ting He

This study is devoted to the design of an elastic polymer thin film-based capacitive wind-pressure sensor to meet the anticipated use for real-time monitoring of structural wind pressure in civil engineering. This sensor is composed of four basic units: lateral elastic deflection unit of a wind-driven circular polymer thin film, parallel plate capacitor with a movable circular electrode plate, spring-driven return unit of the movable electrode plate, and dielectric materials between electrode plates. The capacitance of the capacitor varies with the parallel move of the movable electrode plate which is first driven by the lateral elastic deflection of the wind-driven film and then is, after the wind pressure is reduced or eliminated, returned quickly by the drive springs. The closed-form solution for the contact problem between the wind-driven thin film and the spring-driven movable electrode plate is presented, and its reliability is proved by the experiment conducted. The numerical examples conducted show that it is workable that by using the numerical calibration based on the presented closed-form solution the proposed sensor is designed into a nonlinear sensor with larger pressure-monitoring range and faster response speed than the linear sensor usually based on experimental calibration.


2007 ◽  
Vol 244 (6) ◽  
pp. 2166-2171 ◽  
Author(s):  
Tingchao He ◽  
Yongguang Cheng ◽  
Changshun Wang ◽  
Tingjian Jia ◽  
Pengwei Li ◽  
...  

2012 ◽  
Vol 45 (3) ◽  
pp. 307-312 ◽  
Author(s):  
Takamichi Shinohara ◽  
Tomoko Shirahase ◽  
Daiki Murakami ◽  
Taiki Hoshino ◽  
Moriya Kikuchi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document