scholarly journals Measuring the backscattering coefficient and secondary electron yield inside a scanning electron microscope

Scanning ◽  
1980 ◽  
Vol 3 (1) ◽  
pp. 35-39 ◽  
Author(s):  
L. Reimer ◽  
C. Tollkamp
Author(s):  
Oliver C. Wells

The low-loss electron (LLE) image in the scanning electron microscope (SEM) is useful for the study of uncoated photoresist and some other poorly conducting specimens because it is less sensitive to specimen charging than is the secondary electron (SE) image. A second advantage can arise from a significant reduction in the width of the “penetration fringe” close to a sharp edge. Although both of these problems can also be solved by operating with a beam energy of about 1 keV, the LLE image has the advantage that it permits the use of a higher beam energy and therefore (for a given SEM) a smaller beam diameter. It is an additional attraction of the LLE image that it can be obtained simultaneously with the SE image, and this gives additional information in many cases. This paper shows the reduction in penetration effects given by the use of the LLE image.


Author(s):  
M.G. Rosenfield

Minimum feature sizes in experimental integrated circuits are approaching 0.5 μm and below. During the fabrication process it is usually necessary to be able to non-destructively measure the critical dimensions in resist and after the various process steps. This can be accomplished using the low voltage SEM. Submicron linewidth measurement is typically done by manually measuring the SEM micrographs. Since it is desirable to make as many measurements as possible in the shortest period of time, it is important that this technique be automated.Linewidth measurement using the scanning electron microscope is not well understood. The basic intent is to measure the size of a structure from the secondary electron signal generated by that structure. Thus, it is important to understand how the actual dimension of the line being measured relates to the secondary electron signal. Since different features generate different signals, the same method of relating linewidth to signal cannot be used. For example, the peak to peak method may be used to accurately measure the linewidth of an isolated resist line; but, a threshold technique may be required for an isolated space in resist.


2008 ◽  
Vol 16 (4) ◽  
pp. 62-63
Author(s):  
V.M. Dusevich ◽  
J.H. Purk ◽  
J.D. Eick

Coloring pictures is an educational exercise, which is fun, and helps develop important skills. Coloring SEM micrographs is especially suitable for electron microscopists. Color micrographs are not just great looking on a lab wall; they inspire both microscopists and students to exercise digital picture manipulation. Many microscopists enjoyed looking at the beautiful color micrographs by D. Scharf, but were frustrated to learn they needed a very particular scanning electron microscope equipped with multiple secondary electron detectors in order to color their own pictures. Fortunately, there are other ways to color SEM micrographs. Most SEMs are equipped with at least two detectors, for secondary and backscattered electrons.


1997 ◽  
Vol 3 (S2) ◽  
pp. 385-386 ◽  
Author(s):  
Brendan J. Griffin

The environmental SEM is an extremely adaptive instrument, allowing a range of materials to be examined under a wide variety of conditions. The limitations of the instrument lie mainly with the restrictions imposed by the need to maintain a moderate vacuum around the electron gun. The primary effect of this has been, in a practical sense, the limited low magnification available. Recently this has been overcome by modifications to the final pressure limiting aperture and secondary electron detector (Fig.l). The modifications are simple and users should be brave in this regard.A variety of electron detectors now exist including various secondary, backscattered and cathodoluminescence systems (Figs 2-5). These provide an excellent range of options; the ESEM must be regarded as a conventional SEM in that a range of imaging options should be installed. In some cases, e.g. cathodoluminescence, the lack of coating provides an advantage unique to the low vacuum SEMs.


2014 ◽  
Vol 668-669 ◽  
pp. 936-939
Author(s):  
Quan Wen ◽  
Zhao Yang Ding ◽  
Fu Sheng Kou ◽  
Peng Zhou

Mechanism and functions of S-4800 Scanning Electron Microscope are introduced in this paper. The image-forming mechanism and structure of SEM are studied, and the signal transformation of secondary electron and backscattered electron is presented. The main application fields of SEM are researched.


Sign in / Sign up

Export Citation Format

Share Document