Two-Phase On-Chip Cooling Systems for Green Data Centers

Author(s):  
John R. Thome ◽  
Jackson B. Marcinichen ◽  
Jonathan A. Olivier
2021 ◽  
Author(s):  
Lucas Arrivo ◽  
Steven Schon ◽  
Aaron P. Wemhoff

Abstract Data centers housing high performance computing equipment have large and growing rack densities, which pushes the limits of traditional air cooling technologies because of limited heat transfer coefficients. Therefore, on-chip cooling using so-called cold plates is emerging as a necessary cooling option for high-density electronics. The use of mini-channels or pins fins to enhance internal heat transfer area inside cold plates requires extensive micro-machining that is relatively time consuming and expensive for mass production. As an alternative approach, inserting and bonding pre-manufactured metal foams into hollow bodies are explored as a potentially inexpensive means to enhance the interior heat transfer area of cold plates. One key aspect of the performance of metal foams in cold plates is the thermal contact resistance in the bonding between the foam and the substrate. This project predicts the contact resistance using measurements of different foam types (pure Cu and Cu with oxide), porosities (63%, 80%, 93%, and 95%) and thicknesses (4 mm, 8 mm, and 10 mm). These measurements are carried out with and without the use of thermal interface material (TIM) pads. A theory is proposed and implemented to estimate the contact and foam thermal resistances, but further work is needed to gain confidence in the results. Observations suggest that different thermal behavior is seen for the Cu foams compared to the Cu with oxide foams, and that the use of TIM pads can achieve 10x to 40x reduction in overall thermal resistance for highly porous foams bonded on Cu substrates.


2014 ◽  
Vol 114 ◽  
pp. 179-191 ◽  
Author(s):  
Jackson Braz Marcinichen ◽  
Duan Wu ◽  
Stephan Paredes ◽  
John R. Thome ◽  
Bruno Michel

Author(s):  
Yoshiyuki Abe ◽  
Mayumi Ouchi ◽  
Masato Fukagaya ◽  
Takashi Kitagawa ◽  
Haruhiko Ohta ◽  
...  

Energy utilization in data centers, especially cooling systems for server racks, needs extensive improvement. The present authors proposed advanced cooling network systems for data centers, and R & D activities have been conducted under the so-called Green IT Project sponsored by NEDO (New Energy and Industrial Technology Development Organization). In the present concept, CPUs in servers are cooled down by either direct liquid cooling system or heat pipes with liquid cooling systems in the condensation region. The liquid cooling systems are integrated in each server rack and among server racks. A series of studies on both single phase and two phase narrow channel heat exchangers, high performance heat pipes with self-rewetting fluids and nanofluids for heat transfer enhancement are ongoing. In addition, a prototype server rack with the cooling network systems is also under development toward commercial products. This paper reports the updated status of the present R & D.


2021 ◽  
Author(s):  
Alexander V. Korobko ◽  
Sana Fateh

Abstract The recent increase in complexity of computations and the expansion of edge computing have led to the emergence of high power density data centers with an urgent demand for more advanced thermal management systems. Two-phase passive cooling systems such as thermosyphons and heat pipes have been widely used in industry to maintain the temperature of the servers below the threshold of failure and carry away a large quantity of heat from a small area. Such systems are economically viable and sustainable since they have no moving parts and consume lower power. However, an upgrade to these cooling systems is imminent due to the ever-increasing power densities of the data centers and more challenging thermal management issues faced by the industry. Nanofluids have emerged recently as a new class of cooling liquids claiming to enhance the heat transfer performance in single and two-phase cooling systems. As per several studies presented in this paper, the thermal performance of thermosyphons is shown to be enhanced by employing nanofluids. In this paper, a comprehensive review is presented on the effect of nanofluids in improving the Critical Heat Flux (CHF) and Heat Transfer Coefficient (HTC) in two-phase cooling systems. The boiling phenomenon and working principles of thermosyphons will be discussed to understand the underlying mechanisms affecting heat transfer in the evaporator region, where the heat is absorbed from the source. The impact of nanoparticle features, concentration, and deposition pattern on HTC enhancement will also be studied. Additionally, estimates of the heat dissipation improvement by using nanofluids along with the bottlenecks and challenges faced in applying such fluids practically are reviewed as well. In conclusion, recommendations are made for future research needed to overcome the risks and commercialize the nanofluids in two-phase cooling systems for providing significant improvement in heat transfer performance as compared to conventional working fluids.


Sensors ◽  
2020 ◽  
Vol 20 (19) ◽  
pp. 5533
Author(s):  
Yunlong Qiu ◽  
Wenjie Hu ◽  
Changju Wu ◽  
Weifang Chen

This paper describes an experimental study of the cooling capabilities of microchannel and micro-pin-fin based on-chip cooling systems. The on-chip cooling systems integrated with a micro heat sink, simulated power IC (integrated circuit) and temperature sensors are fabricated by micromachining and silicon-to-silicon direct bonding. Three micro heat sink structures: a microchannel heat sink (MCHS), an inline micro-pin-fin heat sink (I-MPFHS) and a staggered micro-pin-fin heat sink (S-MPFHS) are tested in the Reynolds number range of 79.2 to 882.3. The results show that S-MPFHS is preferred if the water pump can provide enough pressure drop. However, S-MPFHS has the worst performance when the rated pressure drop of the pump is lower than 1.5 kPa because the endwall effect under a low Reynolds number suppresses the disturbance generated by the staggered micro pin fins but S-MPFHS is still preferred when the rated pressure drop of the pump is in the range of 1.5 to 20 kPa. When the rated pressure drop of the pump is higher than 20 kPa, I-MPFHS will be the best choice because of high heat transfer enhancement and low pressure drop price brought by the unsteady vortex street.


Author(s):  
Etienne Costa-Patry ◽  
Stefano Nebuloni ◽  
Jonathan Olivier ◽  
John Richard Thome
Keyword(s):  
Hot Spot ◽  
On Chip ◽  