Probabilistic Analysis of Solar Power Supply Using D-Vine Copulas Based on Meteorological Variables

Author(s):  
Freimut von Loeper ◽  
Tom Kirstein ◽  
Basem Idlbi ◽  
Holger Ruf ◽  
Gerd Heilscher ◽  
...  
2021 ◽  
Vol 11 (4) ◽  
pp. 1776
Author(s):  
Young Seo Kim ◽  
Han Young Joo ◽  
Jae Wook Kim ◽  
So Yun Jeong ◽  
Joo Hyun Moon

This study identified the meteorological variables that significantly impact the power generation of a solar power plant in Samcheonpo, Korea. To this end, multiple regression models were developed to estimate the power generation of the solar power plant with changing weather conditions. The meteorological data for the regression models were the daily data from January 2011 to December 2019. The dependent variable was the daily power generation of the solar power plant in kWh, and the independent variables were the insolation intensity during daylight hours (MJ/m2), daylight time (h), average relative humidity (%), minimum relative humidity (%), and quantity of evaporation (mm). A regression model for the entire data and 12 monthly regression models for the monthly data were constructed using R, a large data analysis software. The 12 monthly regression models estimated the solar power generation better than the entire regression model. The variables with the highest influence on solar power generation were the insolation intensity variables during daylight hours and daylight time.


Author(s):  
Luis Alberto Cantera-Cantera ◽  
Andrés Calvillo-Téllez

A photovoltaic solar power supply is presented; it supplies energy to the electrodes of a wastewater treatment prototype by electrocoagulation. The source will be able to supply three voltages levels 10, 20, and 30 volts, with a current of 1000 mA. The system consists of an array of solar panels and Nickel Metal batteries. The amount of energy to be supplied by the solar panels is estimated, the level of storage in batteries is calculated and fed to the electrocoagulation system. The results of an experiment that operates independently of the power supply line and that works in rural areas are presented.


Author(s):  
Petro Lezhnyuk ◽  
Iryna Hunko ◽  
Juliya Malogulko ◽  
Iryna Kotylko ◽  
Lіudmyla Krot

Urgency of the research. Current trends of distributed generation development in Ukraine indicate a rapid generation in-crease from renewable energy plants. Most developed countries gradually refuse from the fossil fuels use and invest more and more to the “green” energy. Therefore, there is a need for a detailed study of the operation conditions of distributed energy sources due to their instability, as well as the processes that arise in distribution electric networks with diverse types of distributed energy sources. Target setting. In the producing process of power energy by distributed energy sources due to the increase in their num-ber, there are situations where several renewable sources of energy operate to only one system of buses. Thus, such distributive networks acquire the features of a local power system, which complicates the control process of such systems, and also there is a problem with the electricity supply of consumers. Actual scientific researches and issues analysis. The analysis of publications suggests that in literature more attention is paid to studying the operating modes of solar power plants, or small hydroelectric power plants. However, almost no attention was paid to the study of their cooperation work. Uninvestigated parts of general matters defining. Only a few works are devoted to the study of the cooperation of the diverce sources of distributed energy sources in the local electrical systems. That is why, their impact on power distribution networks and on the grid in general has not been studied extensively. The research objective. In this article was considered the influence of asynchronous generators on small hydroelectric power plants on the operation modes of distribution electrical networks, and were investigated the processes that are occurring in local power systems with different types of distributed energy sources. The statement of basic materials. Based on the research results, was developed a computer model of a such system in the PS CAD software environment. Two solar stations and one small hydroelectric power station with an asynchronous generator were connected to the power supply. It was shown the simulation of two modes of operation: a joint operation of a small hydroelectric power station, two solar power stations and a power supply center; a joint operation of a small hydroelectric pow-er plant, two solar power stations and a power supply disconnected. Conclusions. As a result of computer simulation, it is shown that by switching on a small hydroelectric power plant with an asynchronous generator in the case of an emergency shutdown of centralized power supply, it is possible to restore the work of solar power plants, and thus partially or completely restore the power supply of consumers.


2015 ◽  
Vol 16 (5) ◽  
pp. 413-419 ◽  
Author(s):  
Tanveer Ahmad ◽  
Qadeer Ul Hasan ◽  
A. Malik ◽  
N. S. Awan

Abstract This paper presents design and development of solar power monitoring and control through GSM network in rural application. This system includes a GSM mobile and GSM hardware installed at solar system with 12VDC power for solar power monitoring along with temperatures (ambient and battery). This system is designed to conceptualizing how much solar power transferred to batteries and temperature conditions for that instant of time. Hardware is developed for the continuous update to the targeted station using GSM. The developed hardware gets the signal from the installed location calculate the real time power and temperature parameters. This information transferred to targeted mobile station through GSM interface using texting service (SMS). At the receiving end, power monitoring system is used to maintain the power to batteries profile locally. An easy, cost proficient and consistent working model of whole system has been developed which may be incorporated for data acquisition. Also the same system can use for uninterrupted power supply (UPS) systems.