Robot Joint Module Equipped with Joint Torque Sensor with Disk-Type Coupling for Torque Error Reduction

Author(s):  
Jae-Kyung Min ◽  
Hong-Seon Yu ◽  
Kuk-Hyun Ahn ◽  
Jae-Bok Song
1991 ◽  
Vol 27 (6) ◽  
pp. 693-699
Author(s):  
Junichi IMURA ◽  
Toshiharu SUGIE ◽  
Yasuyoshi YOKOKOHJI ◽  
Tsuneo YOSHIKAWA

Measurement ◽  
2020 ◽  
Vol 152 ◽  
pp. 107328
Author(s):  
Kang Han ◽  
Liheng Chen ◽  
Mingyi Xia ◽  
Qinwen Wu ◽  
Zhenbang Xu ◽  
...  

Mechatronics ◽  
2019 ◽  
Vol 63 ◽  
pp. 102265 ◽  
Author(s):  
Jae-Kyung Min ◽  
Kuk-Hyun Ahn ◽  
Hui-Chang Park ◽  
Jae-Bok Song

1987 ◽  
Vol 109 (2) ◽  
pp. 122-127 ◽  
Author(s):  
C. W. deSilva ◽  
T. E. Price ◽  
T. Kanade

This paper describes the development of a joint torque sensor for the second direct-drive manipulator at Carnegie-Mellon University (CMU DD Arm II). The approach taken is to develop the sensor using static design considerations and then test it to verify its dynamic performance. Several design considerations applicable to semiconductor strain-gage torque sensors are presented. These are strain capacity limit, nonlinearity, sensitivity, and stiffness specifications. Associated design equations have been developed in the present work. A numerical example is given to illustrate the use of these design considerations. The development of a circular-shaft torque sensor for the CMU DD Arm II, that employs semiconductor strain gages, is described. Typical results from a static calibration test and from step and impulse tests are presented. Test show that the torque sensor performs well under dynamic conditions in a bandwidth of 100 Hz.


Sign in / Sign up

Export Citation Format

Share Document