Pattern Recognition Pipeline for Neuroimaging Data

Author(s):  
Maxim Sharaev ◽  
Alexander Andreev ◽  
Alexey Artemov ◽  
Evgeny Burnaev ◽  
Ekaterina Kondratyeva ◽  
...  
2013 ◽  
Vol 2013 ◽  
pp. 1-12 ◽  
Author(s):  
Elisa Veronese ◽  
Umberto Castellani ◽  
Denis Peruzzo ◽  
Marcella Bellani ◽  
Paolo Brambilla

In recent years, machine learning approaches have been successfully applied for analysis of neuroimaging data, to help in the context of disease diagnosis. We provide, in this paper, an overview of recent support vector machine-based methods developed and applied in psychiatric neuroimaging for the investigation of schizophrenia. In particular, we focus on the algorithms implemented by our group, which have been applied to classify subjects affected by schizophrenia and healthy controls, comparing them in terms of accuracy results with other recently published studies. First we give a description of the basic terminology used in pattern recognition and machine learning. Then we separately summarize and explain each study, highlighting the main features that characterize each method. Finally, as an outcome of the comparison of the results obtained applying the described different techniques, conclusions are drawn in order to understand how much automatic classification approaches can be considered a useful tool in understanding the biological underpinnings of schizophrenia. We then conclude by discussing the main implications achievable by the application of these methods into clinical practice.


2019 ◽  
Author(s):  
Richard Dinga ◽  
Brenda W.J.H. Penninx ◽  
Dick J. Veltman ◽  
Lianne Schmaal ◽  
Andre F. Marquand

AbstractPattern recognition predictive models have become an important tool for analysis of neuroimaging data and answering important questions from clinical and cognitive neuroscience. Regardless of the application, the most commonly used method to quantify model performance is to calculate prediction accuracy, i.e. the proportion of correctly classified samples. While simple and intuitive, other performance measures are often more appropriate with respect to many common goals of neuroimaging pattern recognition studies. In this paper, we will review alternative performance measures and focus on their interpretation and practical aspects of model evaluation. Specifically, we will focus on 4 families of performance measures: 1) categorical performance measures such as accuracy, 2) rank based performance measures such as the area under the curve, 3) probabilistic performance measures based on quadratic error such as Brier score, and 4) probabilistic performance measures based on information criteria such as logarithmic score. We will examine their statistical properties in various settings using simulated data and real neuroimaging data derived from public datasets. Results showed that accuracy had the worst performance with respect to statistical power, detecting model improvement, selecting informative features and reliability of results. Therefore in most cases, it should not be used to make statistical inference about model performance. Accuracy should also be avoided for evaluating utility of clinical models, because it does not take into account clinically relevant information, such as relative cost of false-positive and false-negative misclassification or calibration of probabilistic predictions. We recommend alternative evaluation criteria with respect to the goals of a specific machine learning model.


2015 ◽  
Vol 2015 ◽  
pp. 1-10 ◽  
Author(s):  
Antonio Cerasa ◽  
Isabella Castiglioni ◽  
Christian Salvatore ◽  
Angela Funaro ◽  
Iolanda Martino ◽  
...  

Presently, there are no valid biomarkers to identify individuals with eating disorders (ED). The aim of this work was to assess the feasibility of a machine learning method for extracting reliable neuroimaging features allowing individual categorization of patients with ED. Support Vector Machine (SVM) technique, combined with a pattern recognition method, was employed utilizing structural magnetic resonance images. Seventeen females with ED (six with diagnosis of anorexia nervosa and 11 with bulimia nervosa) were compared against 17 body mass index-matched healthy controls (HC). Machine learning allowed individual diagnosis of ED versus HC with an Accuracy ≥ 0.80. Voxel-based pattern recognition analysis demonstrated that voxels influencing the classification Accuracy involved the occipital cortex, the posterior cerebellar lobule, precuneus, sensorimotor/premotor cortices, and the medial prefrontal cortex, all critical regions known to be strongly involved in the pathophysiological mechanisms of ED. Although these findings should be considered preliminary given the small size investigated, SVM analysis highlights the role of well-known brain regions as possible biomarkers to distinguish ED from HC at an individual level, thus encouraging the translational implementation of this new multivariate approach in the clinical practice.


Author(s):  
G.Y. Fan ◽  
J.M. Cowley

In recent developments, the ASU HB5 has been modified so that the timing, positioning, and scanning of the finely focused electron probe can be entirely controlled by a host computer. This made the asynchronized handshake possible between the HB5 STEM and the image processing system which consists of host computer (PDP 11/34), DeAnza image processor (IP 5000) which is interfaced with a low-light level TV camera, array processor (AP 400) and various peripheral devices. This greatly facilitates the pattern recognition technique initiated by Monosmith and Cowley. Software called NANHB5 is under development which, instead of employing a set of photo-diodes to detect strong spots on a TV screen, uses various software techniques including on-line fast Fourier transform (FFT) to recognize patterns of greater complexity, taking advantage of the sophistication of our image processing system and the flexibility of computer software.


Author(s):  
L. Fei ◽  
P. Fraundorf

Interface structure is of major interest in microscopy. With high resolution transmission electron microscopes (TEMs) and scanning probe microscopes, it is possible to reveal structure of interfaces in unit cells, in some cases with atomic resolution. A. Ourmazd et al. proposed quantifying such observations by using vector pattern recognition to map chemical composition changes across the interface in TEM images with unit cell resolution. The sensitivity of the mapping process, however, is limited by the repeatability of unit cell images of perfect crystal, and hence by the amount of delocalized noise, e.g. due to ion milling or beam radiation damage. Bayesian removal of noise, based on statistical inference, can be used to reduce the amount of non-periodic noise in images after acquisition. The basic principle of Bayesian phase-model background subtraction, according to our previous study, is that the optimum (rms error minimizing strategy) Fourier phases of the noise can be obtained provided the amplitudes of the noise is given, while the noise amplitude can often be estimated from the image itself.


1989 ◽  
Vol 34 (11) ◽  
pp. 988-989
Author(s):  
Erwin M. Segal
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document