Insertion of Intracranial Monitoring Devices

Author(s):  
Mikko Kauppinen
Keyword(s):  
Author(s):  
Irwin Bendet ◽  
Nabil Rizk

Preliminary results reported last year on the ion etching of tobacco mosaic virus indicated that the diameter of the virus decreased more rapidly at 10KV than at 5KV, perhaps reaching a constant value before disappearing completely.In order to follow the effects of ion etching on TMV more quantitatively we have designed and built a second apparatus (Fig. 1), which incorporates monitoring devices for measuring ion current and vacuum as well as accelerating voltage. In addition, the beam diameter has been increased to approximately 1 cm., so that ten electron microscope grids can be exposed to the beam simultaneously.


2020 ◽  
Vol 98 (Supplement_3) ◽  
pp. 117-117
Author(s):  
Nicole C Burdick Sanchez ◽  
Jeffery A Carroll ◽  
Paul R Broadway ◽  
Tom S Edrington ◽  
Ilkyu Yoon ◽  
...  

Abstract This study was conducted to determine if feeding calves NaturSafe would reduce the acute phase response (APR) to lipopolysaccharide (LPS) challenge. Crossbred steers (n=32; 274±2 kg) were randomly allotted to two treatment diets: 1) Control, fed a standard receiving ration, and 2) NaturSafe, fed the Control ration supplemented with NaturSafe at 12 g/hd/d (NaturSafe®, Diamond V). On d22, steers were fitted with indwelling jugular catheters and rectal temperature monitoring devices and placed in individual stalls. On d23, steers were challenged i.v. with 0.25 µg/kg BW LPS. Serum samples were collected and sickness behavior scores (SBS) recorded at 0.5-h intervals from -2 to 8h and at 24h relative to LPS challenge. Rectal temperatures were greater (P=0.01) in NaturSafe compared to Control steers for the following time intervals following LPS challenge: 6 to 11h, 13h, 15 to 20h, and 22 to 24h. Additionally, SBS were reduced (P< 0.01) in NaturSafe compared to Control steers. White blood cell concentrations were greater (P=0.05) in NaturSafe compared to Control steers prior to the LPS challenge, yet the response to LPS did not differ between treatments (P >0.05). A treatment × time interaction for serum cortisol concentrations (P< 0.01) showed an increase at 0.5 and 2h post-challenge but a reduction at 3h in NaturSafe compared to Control steers. Additionally, fibrinogen was greater (P< 0.01) in NaturSafe compared to Control steers. There was a treatment × time interaction (P< 0.01) for TNF-α where concentrations were reduced from 1 to 2h post-challenge in NaturSafe compared to Control steers. Serum IL-6 tended (P=0.09) to show a reduction in serum concentrations in NaturSafe compared to Control steers. There was a tendency (P=0.07) for a treatment × time interaction for IFN-γ. Overall these data suggest a priming effect of NaturSafe on the innate immune system of steers, resulting in an attenuated APR to the LPS challenge.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
T. Dicu ◽  
B. D. Burghele ◽  
M. Botoş ◽  
A. Cucoș ◽  
G. Dobrei ◽  
...  

AbstractThe present study aims to identify novel means of increasing the accuracy of the estimated annual indoor radon concentration based on the application of temporal correction factors to short-term radon measurements. The necessity of accurate and more reliable temporal correction factors is in high demand, in the present age of speed. In this sense, radon measurements were continuously carried out, using a newly developed smart device accompanied by CR-39 detectors, for one full year, in 71 residential buildings located in 5 Romanian cities. The coefficient of variation for the temporal correction factors calculated for combinations between the start month and the duration of the measurement presented a low value (less than 10%) for measurements longer than 7 months, while a variability close to 20% can be reached by measurements of up to 4 months. Results obtained by generalized estimating equations indicate that average temporal correction factors are positively associated with CO2 ratio, as well as the interaction between this parameter and the month in which the measurement took place. The impact of the indoor-outdoor temperature differences was statistically insignificant. The obtained results could represent a reference point in the elaboration of new strategies for calculating the temporal correction factors and, consequently, the reduction of the uncertainties related to the estimation of the annual indoor radon concentration.


Sign in / Sign up

Export Citation Format

Share Document