scholarly journals Serum-Pool

Author(s):  
C. Vidal ◽  
W.-R. Külpmann
Keyword(s):  
Author(s):  
OSMAN Oğuz ◽  
Huriye Serin ◽  
Fatma Hocaoğlu Emre

Background: Alkaline phosphatase (ALP) enzymes are widely used as signal amplifiers in immunoenzymatic methods. Conditions that cause ALP elevations, such as bone or liver diseases can cause interference in immunoenzymatic methods. Objective: We aimed to examine ALP's effect on immunoenzymatic assay by adding isolated pure ALP to the prepared serum pool. Material and Methods: We prepared a serum pool and divided into 4 groups. By adding isolated pure ALP at different concentrations to each group, we obtained sample groups containing ALP enzyme at concentrations of 85 U/L, 340 U/L, 870 U/L and 1570 U/L. In each group, 20-repetition of βhCG, Ferritin, FT4, TSH, Troponin I and Vit B12 tests were performed. Coefficient of variation, bias, and total error were calculated. All groups were compared by using Friedman test for paired samples. Result: After ALP addition, the calculated total error values of FT4, βhCG and troponin I tests were found to be above the acceptable error limits. There were statistically significant differences in βhCG ,FT4, troponin I and Vit B12 tests when compared to the baseline ALP level (P<0,0125).Conclusion: Isolated ALP elevations can be a source of interference for immunoenzymatic methods.KeywordsAlkaline phosphatase, ALP, bias, immunoenzymatic, total error


Author(s):  
Tejas Kalaria ◽  
Jonathan Fenn ◽  
Richard Whitmill ◽  
Clare Ford ◽  
Rousseau Gama

Background In samples from patients administered rasburicase, ex vivo uricolysis leads to spuriously low uric acid results. The manufacturer’s recommendation of storing the sample in ice-water until analysis, however, does not fully arrest uricolysis. Since uricase activity is affected by pH and metal chelators, we assessed uricolysis inhibition in sodium fluoride-ethylenediaminetetraacetic acid (EDTA)-citrate sample tube (FC Mix tube, Greiner) used primarily for plasma glucose. Method A serum pool was spiked with rasburicase and uric acid measured at 15, 45, 90, 150, 240 and 1080 min in a lithium heparin tube in ice-water, plain tube at room temperature (RT), EDTA tube at RT, FC Mix tube in ice-water, FC Mix tube at RT and FC Mix tube at RT prepared by dissolving FC Mix in serum. Results The rate of urate decay was lowest in the FC Mix tube independent of temperature, then lithium heparin tube in ice-water, then EDTA tube at RT and highest in the plain tube at RT. Uric acid concentrations in the prepared FC Mix tube at RT and heparin tube in ice-water were, respectively, 98.2% and 93.8% of control values at 90 min, 97.1% and 89.3% of control values at 4 h, and remained higher in the prepared FC Mix tube at all time points. Conclusion NaF-EDTA-citrate mixture largely arrested rasburicase mediated ex vivo uricolysis without the need for sample cooling. We propose that sample tubes containing NaF-EDTA-citrate be used for the measurement of uric acid in patients administered rasburicase.


1973 ◽  
Vol 19 (5) ◽  
pp. 492-495 ◽  
Author(s):  
M A Evenson ◽  
Susan Koellner

Abstract Rapid, accurate, and precise gas-chromatographic methods are reported for measurement of propoxyphene ("Darvon") in serum. A sample of 5 ml of serum is required for quantitation in blood after a therapeutic dose of 130-195 mg of propoxyphene; in cases of overdose of propoxyphene, only 1 ml of serum is required in a "toxic method" variation. Neither serum from healthy controls or from hospitalized patients contains interfering substances. Several commonly used analgesic and sedative drugs, added to a serum pool, also did not interfere. Day-to-day precision of the therapeutic method, as measured by the coefficient of variation (CV), is 7%; the CV for the method as applied to overdose cases is less than 3%. Propoxyphene added to serum could be about 86% accounted for analytically.


1999 ◽  
Vol 45 (6) ◽  
pp. 822-828 ◽  
Author(s):  
David J Newman ◽  
Yemi Olabiran ◽  
William D Bedzyk ◽  
Suzette Chance ◽  
Eileen G Gorman ◽  
...  

Abstract Background: Available assays for cardiac troponin I (cTnI) yield numerically different results. The aim of this study was to compare patient values obtained from four cTnI immunoassays. Methods: We studied the Stratus® II assay, the Opus® II assay, the Access® assay, and a research-only cTnI heterogeneous immunoassay that uses the Dade Behring aca® plus immunoassay system equipped with two new noncommercial monoclonal antibodies. Because the aca plus cTnI assay is for research only, we first evaluated and analytically validated it for serum and citrated plasma. Initially, each method was calibrated using the method-specific calibrator supplied by each manufacturer; however, the aca plus cTnI assay was calibrated using patient serum pools containing cTnI and selected on the basis of increased creatine kinase MB isoenzyme and with values assigned by use of the Stratus cTnI assay. For method comparisons, individual patient sample cTnI values were determined and compared with the Stratus II assay. Results: Passing and Bablock regression analysis yielded slopes of 1.44 (r = 0.96; n = 72) for the Opus II vs Stratus II assays; 0.07 (r = 0.91; n = 72) for the Access vs Stratus II assays; and 0.90 (r = 0.91, n = 72) for the aca plus vs Stratus II assays. The recalibration of each method with a Stratus II-assigned serum pool improved, but did not entirely eliminate, the slope differences between the different assays (range, 1.00–1.16). The observed scatter in the correlation curves remained. Conclusion: There is a need to further explore the specificities of these assays with respect to the different circulating forms of cTnI.


1989 ◽  
Vol 35 (3) ◽  
pp. 475-477 ◽  
Author(s):  
G Arevalo

Abstract In ambulatory patients, assay of free thyroxin (FT4) in serum correlates well with thyroid status and with results obtained by equilibrium dialysis. The validity of FT4 results has been questioned mainly in euthyroid patients with altered concentrations of thyroid hormone-binding proteins, as in nonthyroidal illness, hereditary analbuminemia, familial dysalbuminemic hyperthyroxinemia (FDH), and the presence of iodothyronine-binding antibodies. I present here a study of the binding of [125I]T4-derivative to serum proteins in the supernate, which is ordinarily discarded after determination of FT4 by one-step radioimmunoassay with dextran-coated charcoal used to separate the free and bound fractions. The results are expressed as a ratio, with results for a normal serum pool as reference. The average ratio was high in hyperthyroid subjects, 1.26 (SD 0.12, n = 25), and in hypoalbuminemia, 1.20 (SD 0.10, n = 15), and low in FDH, 0.62 (SD 0.11, n = 9), and hypothyroid subjects, 0.90 (SD 0.06, n = 20). In normal individuals it was 0.98 (SD 0.05, n = 30). Determination of the analog-binding rate complements the FT4 result and allows for the recognition of cases with abnormal binding by serum proteins, without recourse to other tests recommended for thyroid-function studies.


1989 ◽  
Vol 122 (2) ◽  
pp. 477-483 ◽  
Author(s):  
U. Fingscheidt ◽  
G. F. Weinbauer ◽  
D. M. Robertson ◽  
D. M. de Kretser ◽  
E. Nieschlag

ABSTRACT A heterologous inhibin radioimmunoassay method to measure inhibin in serum of male cynomolgus (Macaca fascicularis) and rhesus (Macaca mulatta) monkeys has been validated using a specific antibody against bovine 31 kDa inhibin and 125I-labelled 31 kDa inhibin as tracer. A serum pool from male monkeys was used as standard. Serial dilutions of normal monkey serum showed parallel logit–log dose–response curves to purified porcine and bovine inhibin as well as to a female human serum pool. The intra-assay coefficient of variation was 4·2% (n=10) and the interassay coefficient of variation 5·1% (n=10). No loss of inhibin immunoactivity was noted after storage at 23 °C for 5 days or repeated thawing and freezing of the serum samples. Serum from castrated monkeys showed undetectable levels of inhibin. Treatment with a gonadotrophin-releasing hormone agonist for 15 weeks led to a marked suppression of peripheral serum inhibin to concentrations similar to those after hypophysectomy or pituitary stalk section. Journal of Endocrinology (1989) 122, 477–483


2002 ◽  
Vol 48 (9) ◽  
pp. 1520-1525 ◽  
Author(s):  
Henk Baadenhuijsen ◽  
Herman Steigstra ◽  
Christa Cobbaert ◽  
Aldy Kuypers ◽  
Cas Weykamp ◽  
...  

Abstract Background: The Dutch project “Calibration 2000” aims at harmonization of laboratory results via calibration by development of commutable, matrix-based, secondary reference materials. An alternative approach to the NCCLS EP14 protocol for studying commutability of reference materials is presented, the “twin-study design”, which in essence is a multicenter, split-patient-sample, between-field-methods protocol. Methods: The study consisted of the simultaneous analysis of fresh patient sera and potential reference materials (PRMs) for HDL-cholesterol (HDL-C) by 86 laboratories forming 43 laboratory couples. Six subgroups of method combinations were formed. The patient sera were selected and interchanged by each laboratory couple. The PRMs consisted of three types: C37, prepared according to the NCCLS C37 protocol; Fro, frozen selectively pooled human serum; and Lyo, which was the same serum pool as Fro but lyophilized in the presence of sucrose. All PRMs were provided in three HDL-C concentrations. The regression line residuals for the PRMs were normalized by expressing them as multiples of the state-of-the-art within laboratory SD (SDSA). In addition, the extra contribution of each PRM to the total measurement uncertainty, CVNetto, was calculated. Results: Averaged over the three PRM concentrations, 1.6% of the C37 residuals were outside the 3 SDSA limit. For the Fro and Lyo PRMs, these values were 2.4% and 11.1%. CVNetto values for C37, Fro, and Lyo were 2.9%, 4.3%, and 5.3%, respectively. Conclusions: The present twin-study design, as a practical alternative to the NCCLS EP14 protocol, is a viable way of studying commutability characteristics of PRMs. The study suggests that the C37 PRMs are the best candidates for a future reference material.


1974 ◽  
Vol 20 (2) ◽  
pp. 212-216 ◽  
Author(s):  
M A Evenson ◽  
M A Poquette

Abstract A rapid, simple, and sensitive method for quantitation of ethchlorvynol by gas chromatography has been developed. Instrument response is linear to a concentration of 200 mg/liter (2.0-ml sample of serum). Day-to-day (20 days) precision of a 15 mg/liter serum pool was 0.85 mg/liter (SD) and 5.6% (CV). For 30 samples analyzed by both the gas chromatographic method and a colorimetric method, the correlation plot had a slope of 0.989, x and y intercepts near zero, and a correlation coefficient of 0.997. Mean recovery of ethchlorvynol added to serum was 87%. Subsequently, all standards were prepared in serum, to compensate for the nonquantitative yield and to help assure accuracy. Sera from healthy controls and from hospitalized patients contain no endogenous interfering substances, nor did any of a series of commonly prescribed drugs interfere.


1981 ◽  
Vol 241 (2) ◽  
pp. E129-E135 ◽  
Author(s):  
W. D. McCumbee ◽  
H. E. Lebovitz

Diabetes and malnutrition result in decreased somatomedin production and cartilage growth in rats. The growth and metabolism of the Swarm rat chondrosarcoma are dramatically affected by somatomedins. Data presented here show that streptozotocin diabetes and diet restriction inhibit in vivo chondrosarcoma growth. Tumors grown in diabetic rats were significantly smaller than tumors grown in diet-restricted rats showing the same changes in body weight. Insulin treatment increased the rate of tumor growth in diabetic rats. Tumors grown in rigidly controlled diabetic rats were as large as tumors grown in nondiabetic controls. Diet restriction and diabetes reduced the capacity of the serum of the rat to stimulate alpha-amino[14C]isobutyrate uptake and [3H]uridine incorporation into RNA in chondrosarcoma pieces grown in nondiabetic rats. This somatomedin activity of the serum was restored by treating diabetic rats with insulin. There was a significant correlation between the in vitro stimulatory effect of a particular serum pool on chondrosarcoma metabolism and in vivo chondrosarcoma growth in the animals from whom the serum was obtained. These studies demonstrate that the in vivo growth of malignant chondrocytes is similar to that of normal chondrocytes with respect to the role of nutrition and insulin.


Author(s):  
Amitava Dasgupta ◽  
Syed Zaidi ◽  
Myrtle Johnson ◽  
Loretta Chow ◽  
Alice Wells

Background: Significant positive bias of bilirubin in the Trinder salicylate method on automated analysers has been reported. Because the fluorescence polarization immunoassay (FPIA) for salicylate is also widely used in the clinical laboratory, we studied the potential interference of bilirubin in the salicylate FPIA. Methods: Salicylate serum pools (three different pools) were prepared from patients receiving salicylate. We also prepared a normal serum pool containing no salicylate and serum pools containing no salicylate but elevated bilirubin. Aliquots of one salicylate pool were supplemented with various concentrations of bilirubin (42.8- 427.5 µmol/L) and salicylate concentrations were measured by the salicylate FPIA (TDxFLx and AxSYM analysers). We also assayed these specimens with the Trinder salicylate method, using both Synchron LX and Hitachi 917 analysers for comparison with the results obtained by the FPIA method. In another experiment, aliquots of the two other salicylate pools were supplemented with various concentrations of bilirubin (42.8-684.0 µmol/L) in order to further study the effect of very high bilirubin concentrations on the salicylate FPIA. We also added known amounts of salicylate to serum pools containing elevated bilirubin but no salicylate and measured salicylate using the FPIA in order to study the recovery of salicylate in the presence of elevated bilirubin concentrations. Results: The FPIA showed minimal interference from bilirubin. We also observed good recovery of salicylate when specimens high in bilirubin but containing no salicylate were supplemented with known amounts of salicylate and the FPIA was used for the measurement of salicylate concentration. However, we observed falsely low salicylate concentrations with the Trinder method using the Synchron LX (primary wavelength 560 nm, secondary wavelength 700 nm) analyser and falsely increased salicylate concentrations using the same reagent but the Hitachi 917 (primary wavelength 546 nm, no secondary wavelength) analyser in the presence of elevated bilirubin levels compared with the FPIA results. Conclusion: We conclude that the FPIA for salicylate is not affected by high bilirubin concentrations up to 427.5 µmol/L.