Plastic (Tube) Stent Drainage

Author(s):  
Masatsugu Nagahama
Keyword(s):  
2021 ◽  
Vol 09 (03) ◽  
pp. E482-E486
Author(s):  
Stanislas Chaussade ◽  
Einas Abou Ali ◽  
Rachel Hallit ◽  
Arthur Belle ◽  
Maximilien Barret ◽  
...  

Abstract Background and study aims The role that air circulation through a gastrointestinal endoscopy system plays in airborne transmission of microorganisms has never been investigated. The aim of this study was to explore the potential risk of transmission and potential improvements in the system. Methods We investigated and described air circulation into gastrointestinal endoscopes from Fujifilm, Olympus, and Pentax. Results The light source box contains a lamp, either Xenon or LED. The temperature of the light is high and is regulated by a forced-air cooling system to maintain a stable temperature in the middle of the box. The air used by the forced-air cooling system is sucked from the closed environment of the patient through an aeration port, located close to the light source and evacuated out of the box by one or two ventilators. No filter exists to avoid dispersion of particles outside the processor box. The light source box also contains an insufflation air pump. The air is sucked from the light source box through one or two holes in the air pump and pushed from the air pump into the air pipe of the endoscope through a plastic tube. Because the air pump does not have a dedicated HEPA filter, transmission of microorganisms cannot be excluded. Conclusions Changes are necessary to prevent airborne transmission. Exclusive use of an external CO2 pump and wrapping the endoscope platform with a plastic film will limit scatter of microorganisms. In the era of pandemic virus with airborne transmission, improvements in gastrointestinal ventilation systems are necessary to avoid contamination of patients and health care workers.


1983 ◽  
Vol 50 (1-2) ◽  
pp. 1-8 ◽  
Author(s):  
U. Gamer ◽  
R. H. Lance

2010 ◽  
Vol 67 (6) ◽  
pp. 727-730 ◽  
Author(s):  
Leonardo Oliveira Medici ◽  
Hermes Soares da Rocha ◽  
Daniel Fonseca de Carvalho ◽  
Carlos Pimentel ◽  
Ricardo Antunes Azevedo

Despite the massive demand of water for plant irrigation, there are few devices being used in the automation of this process in agriculture. This work evaluates a simple controller to water plants automatically that can be set up with low cost commercial materials, which are large-scale produced. This controller is composed by a ceramic capsule used in common domestic water filters; a plastic tube around 1.5 m long, and a pressostate used in domestic washing machines. The capsule and the pressostate are connected through the tube so that all parts are filled with water. The ceramic capsule is the sensor of the controller and has to be placed into the plant substrate. The pressostate has to be placed below the sensor and the lower it is, the higher is the water tension to start the irrigation, since the lower is the pressostate the higher is the water column above it and, therefore, the higher is the tension inside the ceramic cup to pull up the water column. The controller was evaluated in the control of drip irrigation for small containers filled with commercial organic substrate or soil. Linear regressions explained the relationship between the position of pressostate and the maximum water tension in the commercial substrate (p < 0.0054) and soil (p < 0.0001). Among the positions of the pressostate from 0.30 to 0.90 m below the sensor, the water tension changed from 1 to 8 kPa for commercial substrate and 4 to 13 kPa for the soil. This simple controller can be useful to grow plants, applying water automatically in function of the water tension of the plant substrate.


1998 ◽  
Vol 85 (2) ◽  
pp. 405-410 ◽  
Author(s):  
Klaus Lewandowski ◽  
Thilo Busch ◽  
Hansjörg Lohbrunner ◽  
Susanne Rensing ◽  
Uwe Keske ◽  
...  

To investigate whether relevant levels of nasal nitric oxide (NO) are produced in the absence of paranasal sinuses, we studied 17 healthy baboons, mammals without any paranasal sinuses. The animals were anesthetized with ketamine hydrochloride and breathed spontaneously. While the baboons breathed through a face mask (mouths closed) connected to a respirator, NO concentrations in exhaled gas were sampled from the expiratory limb and analyzed by chemiluminescence. While the animals were breathing ambient air, nasal gas was sampled via a thin plastic tube and analyzed for NO concentrations by chemiluminescence. Mean NO concentration in the exhaled gas was 1.00 ± 0.59 parts/billion, and NO release was 4.28 ± 2.72 nl/min. A NO concentration of 4.79 ± 2.08 parts/billion was found in the nasal gas (NO release: 7.18 ± 3.13 nl/min). An age-dependent increase in nasal NO levels was not observed. Exhaled and nasal NO concentrations in baboons were markedly lower than in mammals with paranasal sinuses, suggesting that paranasal sinuses might be an anatomic requirement for production of relevant nasal NO levels.


2008 ◽  
Vol 19 (1) ◽  
pp. 40-45 ◽  
Author(s):  
Ana Teresa Sant'anna ◽  
Luis Carlos Spolidório ◽  
Lizeti Toledo Oliveira Ramalho

This study performed a histological analysis of the effect of formocresol associated to endotoxin (LPS) in the subcutaneous connective tissue of mice. Ninety mice were randomly assigned to 3 groups (n=30). Each animal received one plastic tube implant containing endotoxin solution (10 mg/mL), formocresol (original formula) or a mixture of endotoxin and formocresol. The endotoxin and formocresol groups served as controls. The periods of analysis were 7, 15 and 30 days. At each experimental period, tissue samples were collected and submitted to routine processing for histological analysis. Endotoxin and formocresol produced necrosis and chronic inflammation at 7 and 15 days. At 30 days, the endotoxin group showed no necrosis, while in the formocresol group necrosis persisted. The formocresol-endotoxin association produced necrosis and chronic inflammation in the same way as observed with formocresol at all experimental periods. In conclusion, formocresol seems not to be able to inactive the toxic effects of endotoxin in connective tissues.


2012 ◽  
Vol 170-173 ◽  
pp. 3046-3049
Author(s):  
Hai Bo Wang ◽  
Yao Cai Zhao ◽  
Qi Zong

Emulsion explosive have well frost resistance, it can be stably detonated at -300C. But there are many misfires occurred in blasting construction of shaft frozen zone. After analysis, the causes was water in the hole frozen and it’s volume increased, so explosive cartridge was pressed, it’s density enlarged, and misfire created when it’s density exceed critical density of stable detonation. Based on analysis, plastic tube casing charge adopted for construction, and prevent misfire effectively.


Sign in / Sign up

Export Citation Format

Share Document