A Comprehensive Study of Image Fusion Techniques and Their Applications

Author(s):  
R. Indhumathi ◽  
S. Nagarajan ◽  
T. Abimala
Author(s):  
F. A. Heckman ◽  
E. Redman ◽  
J.E. Connolly

In our initial publication on this subject1) we reported results demonstrating that contrast is the most important factor in producing the high image quality required for reliable image analysis. We also listed the factors which enhance contrast in order of the experimentally determined magnitude of their effect. The two most powerful factors affecting image contrast attainable with sheet film are beam intensity and KV. At that time we had only qualitative evidence for the ranking of enhancing factors. Later we carried out the densitometric measurements which led to the results outlined below.Meaningful evaluations of the cause-effect relationships among the considerable number of variables in preparing EM negatives depend on doing things in a systematic way, varying only one parameter at a time. Unless otherwise noted, we adhered to the following procedure evolved during our comprehensive study:Philips EM-300; 30μ objective aperature; magnification 7000- 12000X, exposure time 1 second, anti-contamination device operating.


Author(s):  
A. Singh ◽  
A. Dykeman ◽  
J. Jarrelf ◽  
D. C. Villeneuve

Hexachlorobenzene (HCB), a persistent and mobile organochlorine pesticide, occurs in environment. HCB has been shown to be present in human follicular fluid. An objective of the present report, which is part of a comprehensive study on reproductive toxicity of HCB, was to determine the cytologic effects of the compound on ovarian follicles in a primate model.Materials and Methods. Eight Cynomolgus monkeys were housed under controlled conditions at Animal facility of Health and Welfare, Ottawa. Animals were orally administered gelatin capsules containing HCB mixed with glucose in daily dosages of 0.0 or 10 mg/kg b.w. for 90 days; the former was the control group. On the menstrual period following completion of dosing, the monkeys underwent an induction cycle of superovulation. At necropsy, one-half of an ovary from each animal was diced into ca. 2- to 3-mm cubed specimens that were fixed by immersion in 2.5% glutaraldehyde in 0.1 M cacodylate buffer (pH 7.3). Subsequent procedures followed to obtain thin sections that were examined in a Hitachi H-7000 electron microscope have been described earlier.


Author(s):  
D. L. Rohr ◽  
S. S. Hecker

As part of a comprehensive study of microstructural and mechanical response of metals to uniaxial and biaxial deformations, the development of substructure in 1100 A1 has been studied over a range of plastic strain for two stress states.Specimens of 1100 aluminum annealed at 350 C were tested in uniaxial (UT) and balanced biaxial tension (BBT) at room temperature to different strain levels. The biaxial specimens were produced by the in-plane punch stretching technique. Areas of known strain levels were prepared for TEM by lapping followed by jet electropolishing. All specimens were examined in a JEOL 200B run at 150 and 200 kV within 24 to 36 hours after testing.The development of the substructure with deformation is shown in Fig. 1 for both stress states. Initial deformation produces dislocation tangles, which form cell walls by 10% uniaxial deformation, and start to recover to form subgrains by 25%. The results of several hundred measurements of cell/subgrain sizes by a linear intercept technique are presented in Table I.


Author(s):  
F.E. Hossler ◽  
M.I. McKamey ◽  
F.C. Monson

A comprehensive study of the microvasculature of the normal rabbit bladder, revealed unusual "capillary glomeruli" along the lateral walls. Here they are characterized as hemal lymph nodes using light microscopy, SEM, TEM, ink injection, and vascular casting.Bladders were perfused via a cannula placed in the abdominal aorta with either 2% glutaraldehyde in 0.1M cacodylate buffer (pH 7.4) for fixation, 10% India ink in 0.9% saline and 0.1M phosphate (pH 7.4) for vessel tracing, or resin (Mercoximethylmethacrylate: catalyst, 4:1:0.3; Ladd Research Industries) for vascular corrosion casting. Infusion pressure was 100mm Hg. Fixed tissue was sectioned from epon-araldyte resin, and stained with toluidine blue for light microscopy, and lead and uranium for TEM. Ink injected tissue was photographed directly from saline-filled bladders illuminated from below. Resin-filled tissue was macerated in 5% KOH and distilled water. Casts were critical point dried, sputter coated with goldpalladium, and examined by routine SEM at 10 KV.


2005 ◽  
Vol 173 (4S) ◽  
pp. 414-414
Author(s):  
Frank G. Fuechsel ◽  
Agostino Mattei ◽  
Sebastian Warncke ◽  
Christian Baermann ◽  
Ernst Peter Ritter ◽  
...  

2004 ◽  
Vol 43 (03) ◽  
pp. 85-90 ◽  
Author(s):  
E. Lopez Hänninen ◽  
Th. Steinmüller ◽  
T. Rohlfing ◽  
H. Bertram ◽  
M. Gutberlet ◽  
...  

Summary Aim: Minimally invasive resection of hyperfunctional parathyroid glands is an alternative to open surgery. However, it requires a precise preoperative localization. This study evaluated the diagnostic use of magnetic resonance (MR) imaging, parathyroid scintigraphy, and consecutive image fusion. Patients, methods: 17 patients (9 women, 8 men; age: 29-72 years; mean: 51.2 years) with primary hyperparathyroidism were included. Examination by MRI used unenhanced T1- and T2-weighted sequences as well as contrast-enhanced T1-weighted sequences. 99mTc-MIBI scintigraphy consisted of planar and SPECT (single photon emission tomography) imaging techniques. In order to improve the anatomical localization of a scintigraphic focus, SPECT-data were fused with the corresponding MR-data using a modified version of the Express 5.0 software (Advanced Visual Systems, Waltham, MA). Results of image fusion were then compared to histopathology. Results: In 14/17 patients, a single parathyroid adenoma was found. There were 3 cases with hyperplastic glands. MRI detected 10 (71%), scintigraphy 12 (86%) adenomas. Both modalities detected 1/3 patients with hyperplasia. Image fusion improved the anatomical assignment of the 13 scintigraphic foci in five patients and was helpful in the interpretation of inconclusive MR-findings in two patients. Conclusions: Both MRI and 99mTc-MIBI scintigraphy sensitively detect parathyroid adenomas but are less reliable in case of hyperplastic glands. In case of a scintigraphic focus, image fusion considerably improves its topographic assignment. Furthermore, it facilitates the evaluation of inconclusive MRI findings.


Author(s):  
Shreya Joshi ◽  
Ms Bhavyaa ◽  
Suhani Gupta ◽  
Lalita Luthra

Blockchain is considered to be a disruptive core technology. Although many researchers have realized the importance of blockchain, but the research of it is still emerging. It is the record-keeping technology behind bitcoin and is one of the hottest and fastest growing skills in the IT sector today. It serves as an immutable ledger which allows transactions to take place in a decentralized man Blockchain-based applications are rising up, covering numerous fields including finance, healthcare, product management, Internet of Things (IoT), and many more. However, there are still some challenges of blockchain technology such as scalability and security problems which need to be overcome. This paper comprises of a comprehensive study of Blockchain technology. We have included here a deep dive into how blockchains work, its architecture, consensus and various applications. Furthermore, technical challenges are briefly listed.


2020 ◽  
pp. 89-96
Author(s):  
Sergei S. Kapitonov ◽  
Alexei S. Vinokurov ◽  
Sergei V. Prytkov ◽  
Sergei Yu. Grigorovich ◽  
Anastasia V. Kapitonova ◽  
...  

The article describes the results of comprehensive study aiming at increase of quality of LED luminaires and definition of the nature of changes in their correlated colour temperature (CCT) in the course of operation. Dependences of CCT of LED luminaires with remote and close location of phosphor for 10 thousand hours of operation in different electric modes were obtained; the results of comparison between the initial and final radiation spectra of the luminaires are presented; using mathematical statistics methods, variation of luminaire CCT over the service period claimed by the manufacturer is forecast; the least favourable electric operation modes with the highest CCT variation observed are defined. The obtained results have confirmed availability of the problem of variation of CCT of LED luminaires during their operation. Possible way of its resolution is application of more qualitative and therefore expensive LEDs with close proximity of phosphor or LEDs with remote phosphor. The article may be interesting both for manufacturers and consumers of LED light sources and lighting devices using them.


Sign in / Sign up

Export Citation Format

Share Document