Deposition on a flat substrate of gas molecules emerging from a cylindrical channel with an evaporating inner surface

1993 ◽  
Vol 64 (2) ◽  
pp. 124-130 ◽  
Author(s):  
V. V. Levdanskii ◽  
V. G. Leitsyna ◽  
Khoang Wan Viet
2022 ◽  
Vol 8 (1) ◽  
Author(s):  
Shingo Kariya ◽  
Takashi Matsumae ◽  
Yuichi Kurashima ◽  
Hideki Takagi ◽  
Masanori Hayase ◽  
...  

AbstractIn this study, we developed a metal multilayer that can provide hermetic sealing after degassing the assemblies and absorbing the residual gases in the package. A package without a leak path was obtained by the direct bonding of the Au/Pt/Ti layers. After packaging, annealing at 450 °C caused thermal diffusion of the Ti underlayer atoms to the inner surface, which led to absorption of the residual gas molecules. These results indicated that a wafer coated with a Au/Pt/Ti layer can provide hermetic sealing and absorb residual gases, which can simplify vacuum packaging processes in the electronics industry.


Author(s):  
Д.Е. Гук ◽  
Е.Е. Мешков

The problem of acceleration in a cylindrical channel by a compressed gas (in particular, by the detonation products of a mixture of acetylene and oxygen) of a thin flat striker is related to the problem of a falling sheet of paper", since the movement of the striker in the channel is unstable with respect to the lateral displacement. This can lead to a violation of the symmetry of the flight of the striker, its skew and a sharp decrease in the achieved speed of the striker. The possibility of preserving the orientation of the striker by limiting its lateral displacement by a uniform arrangement on the inner surface of the channel (on the forming surface) of several thin strands of polymer fishing line is experimentally shown.


Author(s):  
B. J. Panessa ◽  
J. F. Gennaro

Tissue from the hood and sarcophagus regions were fixed in 6% glutaraldehyde in 1 M.cacodylate buffer and washed in buffer. Tissue for SEM was partially dried, attached to aluminium targets with silver conducting paint, carbon-gold coated(100-500Å), and examined in a Kent Cambridge Stereoscan S4. Tissue for the light microscope was post fixed in 1% aqueous OsO4, dehydrated in acetone (4°C), embedded in Epon 812 and sectioned at ½u on a Sorvall MT 2 ultramicrotome. Cross and longitudinal sections were cut and stained with PAS, 0.5% toluidine blue and 1% azure II-methylene blue. Measurements were made from both SEM and Light micrographs.The tissue had two structurally distinct surfaces, an outer surface with small (225-500 µ) pubescent hairs (12/mm2), numerous stoma (77/mm2), and nectar glands(8/mm2); and an inner surface with large (784-1000 µ)stiff hairs(4/mm2), fewer stoma (46/mm2) and larger, more complex glands(16/mm2), presumably of a digestive nature.


Author(s):  
S.K. Aggarwal ◽  
J. San Antonio

Cisplatin (cis-dichlorodiammineplatinum(II)) a potent antitumor agent is now available for the treatment of testicular and ovarian cancers. It is however, not free from its serious side effects including nephrotoxicity, gastro intestinal toxicity, myelosuppression, and ototoxicity. Here we now report that the drug produces peculiar bloating of the stomach in rats and induces acute ulceration.Wistar-derived rats weighing 200-250 g were administered cisplatin(9 mg/kg) ip as a single dose in 0.15 M NaCl. After 3 days the animals were sacrificed by decapitation. The stomachs were removed, the contents analyzed for pepsin and acidity. The inner surface was examined with a dissecting microscope after a moderate stretching for ulcers. Affected areas were fixed and processed for routine electron microscopy and enzyme cytochemistry.The drug treated animals kept on food and water consistently showed bloating and lesions (Fig. 1) with a frequency of 6-70 ulcers in the rumen section of the stomachs.


Author(s):  
M. Pan ◽  
J.M. Cowley

Electron microdiffraction patterns, obtained when a small electron probe with diameter of 10-15 Å is directed to run parallel to and outside a flat crystal surface, are sensitive to the surface nature of the crystals. Dynamical diffraction calculations have shown that most of the experimental observations for a flat (100) face of a MgO crystal, such as the streaking of the central spot in the surface normal direction and (100)-type forbidden reflections etc., could be explained satisfactorily by assuming a modified image potential field outside the crystal surface. However the origin of this extended surface potential remains uncertain. A theoretical analysis by Howie et al suggests that the surface image potential should have a form different from above-mentioned image potential and also be smaller by several orders of magnitude. Nevertheless the surface potential distribution may in practice be modified in various ways, such as by the adsorption of a monolayer of gas molecules.


Author(s):  
Klaus-Ruediger Peters

Only recently it became possible to expand scanning electron microscopy to low vacuum and atmospheric pressure through the introduction of several new technologies. In principle, only the specimen is provided with a controlled gaseous environment while the optical microscope column is kept at high vacuum. In the specimen chamber, the gas can generate new interactions with i) the probe electrons, ii) the specimen surface, and iii) the specimen-specific signal electrons. The results of these interactions yield new information about specimen surfaces not accessible to conventional high vacuum SEM. Several microscope types are available differing from each other by the maximum available gas pressure and the types of signals which can be used for investigation of specimen properties.Electrical non-conductors can be easily imaged despite charge accumulations at and beneath their surface. At high gas pressures between 10-2 and 2 torr, gas molecules are ionized in the electrical field between the specimen surface and the surrounding microscope parts through signal electrons and, to a certain extent, probe electrons. The gas provides a stable ion flux for a surface charge equalization if sufficient gas ions are provided.


Author(s):  
H. K. Birnbaum ◽  
I. M. Robertson

Studies of the effects of hydrogen environments on the deformation and fracture of fcc, bcc and hep metals and alloys have been carried out in a TEM environmental cell. The initial experiments were performed in the environmental cell of the HVEM facility at Argonne National Laboratory. More recently, a dedicated environmental cell facility has been constructed at the University of Illinois using a JEOL 4000EX and has been used for these studies. In the present paper we will describe the general design features of the JEOL environmental cell and some of the observations we have made on hydrogen effects on deformation and fracture.The JEOL environmental cell is designed to operate at 400 keV and below; in part because of the available accelerating voltage of the microscope and in part because the damage threshold of most materials is below 400 keV. The gas pressure at which chromatic aberration due to electron scattering from the gas molecules becomes excessive does not increase rapidly with with accelerating voltage making 400 keV a good choice from that point of view as well. A series of apertures were placed above and below the cell to control the pressures in various parts of the column.


Author(s):  
Heinz Gross ◽  
Katarina Krusche ◽  
Peter Tittmann

Freeze-drying followed by heavy metal shadowing is a long established and straight forward approach to routinely study the structure of dehydrated macromolecules. Very thin specimens such as isolated membranes or single macromolecules are directly adsorbed on C-coated grids. After rapid freezing the grids are transferred into a suitable vacuum equipment for freeze-drying and heavy metal shadowing.To improve the resolution power of shadowing films we introduced shadowing at very low specimen temperature (−250°C). To routinely do that without the danger of contamination we developed in collaboration with Balzers an UHV (p≤10-9 mbar) machine (BAF500K, Fig.2). It should be mentioned here that at −250°C the specimen surface acts as effective cryopump for practically all impinging residual gas molecules from the residual gas atmosphere.Common high resolution shadowing films (Pt/C, Ta/W) have to be protected from alterations due to air contact by a relatively thick C-backing layer, when transferred via atmospheric conditions into the TEM. Such an additional C-coat contributes disturbingly to the contrast at high resolution.


2020 ◽  
Vol 64 (1-4) ◽  
pp. 47-55
Author(s):  
Takuma Tomizawa ◽  
Haicheng Song ◽  
Noritaka Yusa

This study proposes a probability of detection (POD) model to quantitatively evaluate the capability of eddy current testing to detect flaws on the inner surface of pressure vessels cladded by stainless steel and in the presence of high noise level. Welded plate samples with drill holes were prepared to simulate corrosion that typically appears on the inner surface of large-scale pressure vessels. The signals generated by the drill holes and the noise caused by the weld were examined using eddy current testing. A hit/miss-based POD model with multiple flaw parameters and multiple signal features was proposed to analyze the measured signals. It is shown that the proposed model is able to more reasonably characterize the detectability of eddy current signals compared to conventional models that consider a single signal feature.


Sign in / Sign up

Export Citation Format

Share Document