Design and Fabrication of Dichroic Mirror for High Reflectivity in the Orange-Red Region at 2212 ° Angle of Incidence

1984 ◽  
Vol 13 (3) ◽  
pp. 79-80
Author(s):  
K. N. Chopra ◽  
K. V. Narasimham
Author(s):  
David C. Joy

Electron channeling patterns (ECP) were first found by Coates (1967) while observing a large bulk, single crystal of silicon in a scanning electron microscope. The geometric pattern visible was shown to be produced as a result of the changes in the angle of incidence, between the beam and the specimen surface normal, which occur when the sample is examined at low magnification (Booker, Shaw, Whelan and Hirsch 1967).A conventional electron diffraction pattern consists of an angularly resolved intensity distribution in space which may be directly viewed on a fluorescent screen or recorded on a photographic plate. An ECP, on the other hand, is produced as the result of changes in the signal collected by a suitable electron detector as the incidence angle is varied. If an integrating detector is used, or if the beam traverses the surface at a fixed angle, then no channeling contrast will be observed. The ECP is thus a time resolved electron diffraction effect. It can therefore be related to spatially resolved diffraction phenomena by an application of the concepts of reciprocity (Cowley 1969).


Author(s):  
David C. Joy

In a crystalline solid the regular arrangement of the lattice structure influences the interaction of the incident beam with the specimen, leading to changes in both the transmitted and backscattered signals when the angle of incidence of the beam to the specimen is changed. For the simplest case the electron flux inside the specimen can be visualized as the sum of two, standing wave distributions of electrons (Fig. 1). Bloch wave 1 is concentrated mainly between the atom rows and so only interacts weakly with them. It is therefore transmitted well and backscattered weakly. Bloch wave 2 is concentrated on the line of atom centers and is therefore transmitted poorly and backscattered strongly. The ratio of the excitation of wave 1 to wave 2 varies with the angle between the incident beam and the crystal structure.


Author(s):  
W. E. Lee ◽  
A. H. Heuer

IntroductionTraditional steatite ceramics, made by firing (vitrifying) hydrous magnesium silicate, have long been used as insulators for high frequency applications due to their excellent mechanical and electrical properties. Early x-ray and optical analysis of steatites showed that they were composed largely of protoenstatite (MgSiO3) in a glassy matrix. Recent studies of enstatite-containing glass ceramics have revived interest in the polymorphism of enstatite. Three polymorphs exist, two with orthorhombic and one with monoclinic symmetry (ortho, proto and clino enstatite, respectively). Steatite ceramics are of particular interest a they contain the normally unstable high-temperature polymorph, protoenstatite.Experimental3mm diameter discs cut from steatite rods (∼10” long and 0.5” dia.) were ground, polished, dimpled, and ion-thinned to electron transparency using 6KV Argon ions at a beam current of 1 x 10-3 A and a 12° angle of incidence. The discs were coated with carbon prior to TEM examination to minimize charging effects.


Author(s):  
W.S. Putnam ◽  
C. Viney

Many sheared liquid crystalline materials (fibers, films and moldings) exhibit a fine banded microstructure when observed in the polarized light microscope. In some cases, for example Kevlar® fiber, the periodicity is close to the resolution limit of even the highest numerical aperture objectives. The periodic microstructure reflects a non-uniform alignment of the constituent molecules, and consequently is an indication that the mechanical properties will be less than optimal. Thus it is necessary to obtain quality micrographs for characterization, which in turn requires that fine detail should contribute significantly to image formation.It is textbook knowledge that the resolution achievable with a given microscope objective (numerical aperture NA) and a given wavelength of light (λ) increases as the angle of incidence of light at the specimen surface is increased. Stated in terms of the Abbe resolution criterion, resolution improves from λ/NA to λ/2NA with increasing departure from normal incidence.


2020 ◽  
pp. 116-122
Author(s):  
Emre Öztürk ◽  
Mehmet Aktaş ◽  
Tunç Şenyüz

The purpose of this research is to reach good correlation between sun load simulation and solar focusing test for exterior automotive lighting products. Light coming from sun is highly collimated (parallel rays) and focusable from lenses with concave structure. Focusing incidence leads to a hot spot on lens surrounding plastic parts which may cause melting failures at high temperature zones. Sun load simulation is performing to eliminate risk of discoloration, deformation, out gassing, coating failures and fire with prolonged exposure from field. Irradiance values in W/m2 defined in simulation as heat source depending of an angle of incidence of the sun radiation. At first step, simulation is performing with 5 degree intervals to define the critical zones then intervals decreased to 2 degree to detect the critical azimuth and inclination angles. Critical azimuth and inclination angles is checking with ray trace analysis to check the bouncing of sun rays and possible solution to eliminate focuses with design solutions. After numerical analysis to release and validate the automotive lighting products regarding the sun load test, measurement with first parts is necessary. Measurement is performing for all critical angles which have been detected at simulation with thermal camera under ultra high-collimation solar simulator. Measured temperatures are settled according to environment conditions and correlation is checking with simulations.


Author(s):  
A. G. Belova ◽  
E. V. Zimina ◽  
N. P. Simbirtsev

During a pathoanatomic autopsy, it is very important to correctly assess the color change of the organs. However, it is not always clear because the color depends on the spectrum of the incident light. There is also a subjective assessment of color. In addition, in animals with large amounts of circulating blood, for example, dogs, early imbibition occurs, which makes it difficult to assess the color of the organ and pathoanatomical diagnosis. We have proposed a simple and visual method of recognition of two pathological processes – inflammation and edema using colored filters. This technique also allows to accurately differentiate inflammation from postmortem imbibition, to recognize fibrin and hemorrhage well. Postmortem examination of different types of animals (predacious families of mustelids, canids, felids) was performed in accordance with Shore’s method in the prosectorium of the Pathonomy Department, K.I. Skryabin Moscow State Academy of Veterinary Medicine and Biotechnology visual analysis – under various artificial lights (fluorescent lamps with banded spectrum and halogen lamps). In the red filter are well identified the pathological processes associated with the venous blood presence in the tissues (venous hyperemia and pulmonary edema). The focus of venous hyperemia or edema in the red filter looks like a dark zone, and tissues, where arterial bloods predominated, aren’t detected in red filter. In the yellow – green filter the inflammation is clearly detected: the zone is brightly red and surrounding tissues become dark. Red colour filters have rather narrow band of transmittance from 600 to 700 nm. Yellow-green have a width zone – from 500 to 700 nm, including both red, and yellow-green part of spectrum. Oxidized hemoglobin in red part of spectrum absorbs ten time weaker, has more high reflectivity and looks red. Surrounding tissues reflect the red rays, which incident on them also red. Therefore, the zone of edema, venous hyperemia and hemorrhaging, containing venous blood, are detected the dark spot, and inflammation zone merges with the red background. Oxidized hemoglobin in the red spectrum part absorbs ten time weaker than reduced hemoglobin, has high reflectivity of the red spectrum part and looks brightly red, surrounding tissues reflect yellow-green spectrum part and look green. Therefore, the zones of inflammation, active hyperemia and hemorrhaging, containing arterial blood, sharp contrast with green background and are clearly visible. Diagnoses made with the help of color filters are confirmed by histological studies.


2020 ◽  
pp. 1-9 ◽  
Author(s):  
Benjamin Davidson ◽  
Karim Mithani ◽  
Yuexi Huang ◽  
Ryan M. Jones ◽  
Maged Goubran ◽  
...  

OBJECTIVEMagnetic resonance imaging–guided focused ultrasound (MRgFUS) is an emerging treatment modality that enables incisionless ablative neurosurgical procedures. Bilateral MRgFUS capsulotomy has recently been demonstrated to be safe and effective in treating obsessive-compulsive disorder (OCD) and major depressive disorder (MDD). Preliminary evidence has suggested that bilateral MRgFUS capsulotomy can present increased difficulties in reaching lesional temperatures as compared to unilateral thalamotomy. The authors of this article aimed to study the parameters associated with successful MRgFUS capsulotomy lesioning and to present longitudinal radiographic findings following MRgFUS capsulotomy.METHODSUsing data from 22 attempted MRgFUS capsulotomy treatments, the authors investigated the relationship between various sonication parameters and the maximal temperature achieved at the intracranial target. Lesion volume and morphology were analyzed longitudinally using structural and diffusion tensor imaging. A retreatment procedure was attempted in one patient, and their postoperative imaging is presented.RESULTSSkull density ratio (SDR), skull thickness, and angle of incidence were significantly correlated with the maximal temperature achieved. MRgFUS capsulotomy lesions appeared similar to those following MRgFUS thalamotomy, with three concentric zones observed on MRI. Lesion volumes regressed substantially over time following MRgFUS. Fractional anisotropy analysis revealed a disruption in white matter integrity, followed by a gradual return to near-baseline levels concurrent with lesion regression. In the patient who underwent retreatment, successful bilateral lesioning was achieved, and there were no adverse clinical or radiographic events.CONCLUSIONSWith the current iteration of MRgFUS technology, skull-related parameters such as SDR, skull thickness, and angle of incidence should be considered when selecting patients suitable for MRgFUS capsulotomy. Lesions appear to follow morphological patterns similar to what is seen following MRgFUS thalamotomy. Retreatment appears to be safe, although additional cases will be necessary to further evaluate the associated safety profile.