Post-assay growth of gold nanoparticles as a tool for highly sensitive lateral flow immunoassay. Application to the detection of potato virus X

2018 ◽  
Vol 185 (11) ◽  
Author(s):  
Vasily G. Panferov ◽  
Irina V. Safenkova ◽  
Anatoly V. Zherdev ◽  
Boris B. Dzantiev
2020 ◽  
Author(s):  
Vasily Panferov ◽  
Irina V. Safenkova ◽  
Anatoly V. Zherdev ◽  
Boris B. Dzantiev

<div>The approach to inhibit endogenous peroxidases by elevated concentrations of hydrogen peroxide while maintaining the high peroxidase-mimicking activity of Au@Pt nanozymes was developed. The approach facilitates selective and highly-sensitive detection of peroxidase-mimicking nanozyme nanozymes in the background of endogenous peroxidases. Au@Pt nanozyme was used as the colorimetric and catalytic label in lateral flow immunoassay of an important plant pathogen – potato virus X. The inhibition of endogenous peroxidases in plant extracts and selective detection of Au@Pt nanozyme provides the lowest limit of detection among immunochemical assays of potato virus X (up to 500 times lower compared to the assay with conventional gold nanoparticles). </div><div>The proposed approach uses the fundamental principle of enzyme inhibition by the substrate. It is universal and applicable to all matrixes with peroxidase activity. </div>


2018 ◽  
Vol 1007 ◽  
pp. 50-60 ◽  
Author(s):  
Shyatesa C. Razo ◽  
Vasily G. Panferov ◽  
Irina V. Safenkova ◽  
Yuri A. Varitsev ◽  
Anatoly V. Zherdev ◽  
...  

2017 ◽  
Vol 185 (1) ◽  
Author(s):  
Vasily G. Panferov ◽  
Irina V. Safenkova ◽  
Yury A. Varitsev ◽  
Anatoly V. Zherdev ◽  
Boris B. Dzantiev

2020 ◽  
Author(s):  
Vasily Panferov ◽  
Irina V. Safenkova ◽  
Anatoly V. Zherdev ◽  
Boris B. Dzantiev

<div>The approach to inhibit endogenous peroxidases by elevated concentrations of hydrogen peroxide while maintaining the high peroxidase-mimicking activity of Au@Pt nanozymes was developed. The approach facilitates selective and highly-sensitive detection of peroxidase-mimicking nanozyme nanozymes in the background of endogenous peroxidases. Au@Pt nanozyme was used as the colorimetric and catalytic label in lateral flow immunoassay of an important plant pathogen – potato virus X. The inhibition of endogenous peroxidases in plant extracts and selective detection of Au@Pt nanozyme provides the lowest limit of detection among immunochemical assays of potato virus X (up to 500 times lower compared to the assay with conventional gold nanoparticles). </div><div>The proposed approach uses the fundamental principle of enzyme inhibition by the substrate. It is universal and applicable to all matrixes with peroxidase activity. </div>


Nanomaterials ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 768
Author(s):  
Hyung-Mo Kim ◽  
Chiwoo Oh ◽  
Jaehyun An ◽  
Seungki Baek ◽  
Sungje Bock ◽  
...  

Exosomes are attracting attention as new biomarkers for monitoring the diagnosis and prognosis of certain diseases. Colorimetric-based lateral-flow assays have been previously used to detect exosomes, but these have the disadvantage of a high limit of detection. Here, we introduce a new technique to improve exosome detection. In our approach, highly bright multi-quantum dots embedded in silica-encapsulated nanoparticles (M–QD–SNs), which have uniform size and are brighter than single quantum dots, were applied to the lateral flow immunoassay method to sensitively detect exosomes. Anti-CD63 antibodies were introduced on the surface of the M–QD–SNs, and a lateral flow immunoassay with the M–QD–SNs was conducted to detect human foreskin fibroblast (HFF) exosomes. Exosome samples included a wide range of concentrations from 100 to 1000 exosomes/µL, and the detection limit of our newly designed system was 117.94 exosome/μL, which was 11 times lower than the previously reported limits. Additionally, exosomes were selectively detected relative to the negative controls, liposomes, and newborn calf serum, confirming that this method prevented non-specific binding. Thus, our study demonstrates that highly sensitive and quantitative exosome detection can be conducted quickly and accurately by using lateral immunochromatographic analysis with M–QD–SNs.


2021 ◽  
Author(s):  
Vasily G. Panferov ◽  
Shyatesa C. Razo ◽  
Irina V. Safenkova ◽  
Anatoly V. Zherdev ◽  
Boris B. Dzantiev

2019 ◽  
Vol 11 (22) ◽  
pp. 2937-2942 ◽  
Author(s):  
Mingsong Zhu ◽  
Yurui Jia ◽  
Lizhi Peng ◽  
Jifu Ma ◽  
Xiangru Li ◽  
...  

A lateral flow immunoassay was developed to improve clinical care compared with conventional brucellosis screening methods. Detection is dual-color in format using dyed, carboxyl-functionalized latex microspheres synthesized with a one-step method.


2019 ◽  
Vol 297 ◽  
pp. 124965 ◽  
Author(s):  
Abdelrahim Hussein Abdelazeem Hassan ◽  
José Francisco Bergua ◽  
Eden Morales-Narváez ◽  
Arben Mekoçi

Sign in / Sign up

Export Citation Format

Share Document